WARNING: Any change to this heater or its con- trols can be dangerous.

In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

Due to high temperatures, the appliance should be lo- cated out of traffic and away from furniture and draperies.

The appliance area must be kept clear and free from com- bustible materials, gasoline and other flammable vapors and liquids.

Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition.

Installation and repair must be done by a qualified ser- vice person or gas appliance installer.

The appliance must be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding material, dust and pet hair, etc. It is important that the control compartment, burners and circulating air passageways of the appliance be kept clean.

DO NOT place clothing or other flammable material on or near the appliance.

This appliance must only be used with pressures at the inlet as shown in Table 1, Page 12.

The installation must conform with local codes or, in the absence of local codes, with the NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, latest edition.

Any safety screen or guard removed for servicing an ap- pliance must be replaced prior to operating the heater.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kpa).

The appliance must be isolated from the gas supply piping system by closing its equipment shut-off valve during any test- ing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG.

DO NOT use this heater in recreational vehicles, bedrooms or bathrooms.

If this is the ONLY gas appliance, we recommend a minimum 200 pound cylinder with a fill gauge. Use of a 100 pound cylinder is not recommended. Other household gas appliances may require the tank size to be larger. Do not operate the vent-free heater if the fuel level in the propane tank is below 1/4 full. Use only with two-stage regulator.

DO NOT use this heater if any part of it has been under water. Immediately call a qualified technician to inspect the ap- pliance and replace any part of the control system and any gas control which has been under water.

Any outside air ducts in the fireplace shall be permanently closed at the time of appliance installation.

Check local, state or city codes to determine if unvented heaters are permitted. If unvented heaters are not per- mitted, the fireplace chimney damper must be fixed at a minimum dimension of 34 sq. inches. This must be ac- complished by a clamp or screw on the chimney damper

to stop at the minimum vent area. The fireplace must also have a minimum vent opening of 34 sq. ins., (Fig. 1)

This appliance may be installed in an after-market* manu- factured “mobile” home where not prohibited by state or local codes.

OUTSIDE AIR DAMPER OR ASH DUMP (IF PRESENT) MUST BE CLOSED AND SEALED.

Young children should be carefully supervised when they are in the same room with the appliance.

An unvented room heater having an input rating of more than 10,000 btu per hour shall not be installed in a bed- room or bathroom.

Keep the burner and control compartment clean. See main- tenance instructions in this manual.

Never use the heater at a setting between the positions shown on the control knob as this can result in improper combustion and excessive carbon monoxide emissions.

The appliance must be operated with glass doors fully open.

DO NOT operate ceiling fan in room or area with logs when logs are on.

Solid fuels (i.e. wood, paper, trash) shall not be burned in a masonry or UL 127 factory-built fireplace in which an unvented room heater is installed.

*After-market: Completion of sale, not for purpose of re-sale from the manufacturer.

WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL 127 fac- tory-built fireplace or in a listed ventless firebox enclosure. It has been designed certified for these installations. Exception: DO NOT install this ap- pliance in a factory-built fireplace that includes in- structions stating it has not been tested or should not be used with unvented gas logs.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat ex- changer insert or other accessory not approved for use with this heater.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

20008056

3

Image 3
Contents Installation and Operating Instructions for Gas Log Heaters Table of Contents Important Information Important Safeguards High Elevations Installation RequirementsLog Usage Chart Model Wood Burning Fireplace SeriesVent Free Fireplace Series Converting Confined Space to Unconfined Space Provisions for Adequate Combustion and Ventilation AirSupplying Adequate Ventilation Determining if You Have a Confined or Un- confined SpaceMinimum flue diameter and flue damper positions Location InstallationUnpacking Fireplace PreparationMinimum clearance to wall and ceiling No Canopy UsedTypical Gas Line Connection Gas ConnectionGas Inlet Pressure Natural Propane Gas Pressure CheckCounterclockwise ClockwiseCleaning Flame CheckNatural Gas Propane Gas Split Bark Logset Positioning LogsCharred Oak Logset Position log so notch fits securely and rests on valve cover Repair Parts ServicingDescription For Majestic Fireplaces Vent-Free Gas Appliances CFM Corporation cement logs, fiber logs, or firebox linersCFM Corporation CFM Corporation

UVHK29MN, UVHK23MP, UVHK31MP, UVHK36MN specifications

The CFM UVHK series is a line of high-performance and versatile indoor units designed for precise temperature control and energy efficiency. The UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models each boast unique features that make them suitable for various applications, offering both comfort and reliability.

One of the key features of the UVHK series is its advanced inverter technology. This technology allows the units to adjust their compressor speed according to the cooling or heating demand, ensuring optimal energy consumption. As a result, users can enjoy significant energy savings while maintaining comfortable indoor temperatures.

The UVHK36MN model is particularly notable for its high cooling capacity, making it ideal for larger spaces. With a cooling capacity of 36,000 BTUs, it can efficiently manage heat loads in commercial environments or spacious residential areas. It also offers a wide operating range, which means it can perform well even in extreme weather conditions.

In contrast, the UVHK31MP is tailored for medium-sized spaces, with a balanced capacity that offers both cooling and heating options. Its sleek design and quiet operation make it suitable for office installations, where creating a comfortable atmosphere is essential for productivity.

The UVHK23MP is specifically designed for smaller rooms and residential use. This model combines compact size with power, making it perfect for apartments and small houses. With its user-friendly controls and efficient performance, the UVHK23MP offers convenience without sacrificing comfort.

The UVHK29MN strikes a balance between capacity and size, catering to both residential and small commercial applications. Its dual functionality allows for both cooling and heating, making it a practical choice throughout the year.

Across the UVHK series, the units are equipped with advanced filtration systems that purify the air, ensuring a healthier indoor environment. They are also designed for low noise levels, minimizing disturbance to occupants.

In summary, the CFM UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models provide a robust solution for climate control needs. With their inverter technology, energy efficiency, and user-friendly features, these units are ideal for a wide range of applications, ensuring comfort and satisfaction for users.