CFM UVHK36MN, UVHK29MN, UVHK23MP, UVHK31MP manual Installation Requirements, High Elevations

Page 5

Installation Requirements

The fireplace must meet the minimum dimensions listed below. (Fig. 1) Do not install the logset if the fireplace does not meet these minimums.

 

 

Min. Fireplace Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTU/hr.

 

 

 

 

A

B

C

D

Inlet Supply

 

 

 

 

Logset

Gas

Front

Rear

Overall

Overall

Pressure (w.c.)

Manifold

Low

Med.

High

Air Shutter

 

 

Width

Width

Depth

Height

 

Min.

Max.

Pressure

Input

Input

Input

Setting

UVHK36MN

Natural

28”

18”

14¹⁄

17”

5.5”

14.0”

3.5”

10,000

22,500

36,000

.136” (1)

UVHK31MP

Propane

28”

18”

14¹⁄

17”

11.0”

14.0”

11.0”

10,000

20,000

31,000

.136” (2)

UVHK29MN

Natural

23”

16”

14¹⁄

17”

5.5”

14.0”

3.5”

16,000

--

29,000

.136” (1)

UVHK23MP

Propane

23”

16”

14¹⁄

17”

11.0”

14.0”

11.0”

14,000

--

23,000

.136” (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Front width

 

 

 

 

 

B. Rear width

C. Depth

 

 

 

 

 

D. Height

FD370-2

Fig. 1 Minimum fireplace dimensions.

High Elevations

Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370m) above sea level.

Nuisance outages may occur at altitudes above 4,500 feet (1,370m) if dirt, dust, lint and/or cob- webs are allowed to accumulate on burner and/or ODS pilot. Monthly inspection and cleaning is recommended for altitudes above 4,500 feet (1,370m)

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m)

Pressure Test Points

The gas control is equipped with a captured screw-type pressure test point, therefore it is not necessary to pro- vide a 1/8” test point upstream of the control.

Odor During Operation

Neither natural gas nor propane gas give off an odor when burned. The nature of a vent free combustion system, however, is such that odors may occasionally be produced during heater operation when impurities exist in the immediate area. Cleaning solutions, paint, solvents, cigarette smoke, candles, adhesives, new car- pet or textiles, etc., all can create fumes. These fumes may mix with combustion air and can create odor. Such odors will disappear over time, however, the condition can be alleviated by opening a window or otherwise providing additional ventilation to the area.

WARNING

This appliance is for installation in a solid-fuel burning masonry, fireplace with a working flue, a U.L.-127 listed manufactured solid-fuel burn- ing fireplace, in any Majestic ventless firebox, or in any listed ventless firebox enclosure certified to I.A.S. U.S. Requirement 2-97 or ANSI Z21.91.

NOTICE

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventila- tion air must be provided. Refer to Pages 7 and 8.

20008056

5

Image 5
Contents Installation and Operating Instructions for Gas Log Heaters Table of Contents Important Information Important Safeguards High Elevations Installation RequirementsVent Free Fireplace Series Log Usage ChartModel Wood Burning Fireplace Series Supplying Adequate Ventilation Provisions for Adequate Combustion and Ventilation AirDetermining if You Have a Confined or Un- confined Space Converting Confined Space to Unconfined SpaceMinimum flue diameter and flue damper positions Unpacking InstallationFireplace Preparation LocationMinimum clearance to wall and ceiling No Canopy UsedTypical Gas Line Connection Gas ConnectionGas Inlet Pressure Natural Propane Gas Pressure CheckCounterclockwise ClockwiseNatural Gas Propane Gas CleaningFlame Check Split Bark Logset Positioning LogsCharred Oak Logset Position log so notch fits securely and rests on valve cover Description Repair PartsServicing CFM Corporation For Majestic Fireplaces Vent-Free Gas AppliancesCFM Corporation cement logs, fiber logs, or firebox liners CFM Corporation

UVHK29MN, UVHK23MP, UVHK31MP, UVHK36MN specifications

The CFM UVHK series is a line of high-performance and versatile indoor units designed for precise temperature control and energy efficiency. The UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models each boast unique features that make them suitable for various applications, offering both comfort and reliability.

One of the key features of the UVHK series is its advanced inverter technology. This technology allows the units to adjust their compressor speed according to the cooling or heating demand, ensuring optimal energy consumption. As a result, users can enjoy significant energy savings while maintaining comfortable indoor temperatures.

The UVHK36MN model is particularly notable for its high cooling capacity, making it ideal for larger spaces. With a cooling capacity of 36,000 BTUs, it can efficiently manage heat loads in commercial environments or spacious residential areas. It also offers a wide operating range, which means it can perform well even in extreme weather conditions.

In contrast, the UVHK31MP is tailored for medium-sized spaces, with a balanced capacity that offers both cooling and heating options. Its sleek design and quiet operation make it suitable for office installations, where creating a comfortable atmosphere is essential for productivity.

The UVHK23MP is specifically designed for smaller rooms and residential use. This model combines compact size with power, making it perfect for apartments and small houses. With its user-friendly controls and efficient performance, the UVHK23MP offers convenience without sacrificing comfort.

The UVHK29MN strikes a balance between capacity and size, catering to both residential and small commercial applications. Its dual functionality allows for both cooling and heating, making it a practical choice throughout the year.

Across the UVHK series, the units are equipped with advanced filtration systems that purify the air, ensuring a healthier indoor environment. They are also designed for low noise levels, minimizing disturbance to occupants.

In summary, the CFM UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models provide a robust solution for climate control needs. With their inverter technology, energy efficiency, and user-friendly features, these units are ideal for a wide range of applications, ensuring comfort and satisfaction for users.