CFM UVHK29MN, UVHK36MN, UVHK23MP, UVHK31MP manual Important Safeguards

Page 4

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusu- ally tight construction, provide adequate com- bustion and ventilation air by one of the methods described in the National Fuel Gas code, ANSI Z223.1/NFPA 54, Section 5.3, (or applicable local codes).

The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are con- sidered a part of the unconfined space.

WARNING: During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents.

These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches and eye/lung irritation. This is a normal and temporary occurrence.

Important Safeguards

Although your gas logs are very realistic in appearance, it is not a real wood-burning fireplace and must not be used for burning rejected material.

To avoid irreparable damage to the appliance or personal in- jury; matches, paper, garbage or any other material must not be placed or thrown on top of the logs or into the flames.

To avoid personal injury, do not touch hot surfaces when the appliance is operating.

Touch only the piezo button and control knob. Avoid contact with the front screen, canopy or any other part which will be very hot.

Always ensure that the fireplace screen is in place when the appliance is operating and, unless other provisions for combustion air are provided, the screen shall have opening(s) for introduction of combustion air.

Close supervision is necessary when the appliance is be- ing operated near children.

Do not use to cook food.

If this is the ONLY gas appliance, we recommend a minimum 200 pound cylinder with a fill gauge. Use of a 100 pound cylinder is not recommended. Other household gas appli- ances may require the tank size to be larger. Do not operate the vent free fireplace if the fuel level in the propane tank is below 1/4 full.

WARNING: The glowing ember base and all the logs are manufactured from bonded ceramic fiber. This is a commonly used material in indus- try worldwide. In the event of the logs and base being removed, care should be taken not to dam- age the bonded material.

Intentional misuse of, or deliberately fragment- ing, the material could lead to inhaling fibers and be injurious to health.

This appliance is intended to be used only for supplemental heat. Do not use it routinely as a primary heat source. Continuous operation could produce excessive humidity de- pending on construction characteristics and outdoor tempera- tures (below 20°F). Over time, this could cause condensation to form and damage wall structures and exterior paint.

WARNING: Failure to keep primary air opening(s) of the burner(s) clean may result in sooting and property damage.

4

20008056

Image 4
Contents Installation and Operating Instructions for Gas Log Heaters Table of Contents Important Information Important Safeguards Installation Requirements High ElevationsModel Wood Burning Fireplace Series Log Usage ChartVent Free Fireplace Series Provisions for Adequate Combustion and Ventilation Air Supplying Adequate VentilationDetermining if You Have a Confined or Un- confined Space Converting Confined Space to Unconfined SpaceMinimum flue diameter and flue damper positions Installation UnpackingFireplace Preparation LocationNo Canopy Used Minimum clearance to wall and ceilingGas Connection Typical Gas Line ConnectionGas Pressure Check Gas Inlet Pressure Natural PropaneClockwise CounterclockwiseFlame Check CleaningNatural Gas Propane Gas Positioning Logs Split Bark LogsetCharred Oak Logset Position log so notch fits securely and rests on valve cover Servicing Repair PartsDescription CFM Corporation cement logs, fiber logs, or firebox liners For Majestic Fireplaces Vent-Free Gas AppliancesCFM Corporation CFM Corporation

UVHK29MN, UVHK23MP, UVHK31MP, UVHK36MN specifications

The CFM UVHK series is a line of high-performance and versatile indoor units designed for precise temperature control and energy efficiency. The UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models each boast unique features that make them suitable for various applications, offering both comfort and reliability.

One of the key features of the UVHK series is its advanced inverter technology. This technology allows the units to adjust their compressor speed according to the cooling or heating demand, ensuring optimal energy consumption. As a result, users can enjoy significant energy savings while maintaining comfortable indoor temperatures.

The UVHK36MN model is particularly notable for its high cooling capacity, making it ideal for larger spaces. With a cooling capacity of 36,000 BTUs, it can efficiently manage heat loads in commercial environments or spacious residential areas. It also offers a wide operating range, which means it can perform well even in extreme weather conditions.

In contrast, the UVHK31MP is tailored for medium-sized spaces, with a balanced capacity that offers both cooling and heating options. Its sleek design and quiet operation make it suitable for office installations, where creating a comfortable atmosphere is essential for productivity.

The UVHK23MP is specifically designed for smaller rooms and residential use. This model combines compact size with power, making it perfect for apartments and small houses. With its user-friendly controls and efficient performance, the UVHK23MP offers convenience without sacrificing comfort.

The UVHK29MN strikes a balance between capacity and size, catering to both residential and small commercial applications. Its dual functionality allows for both cooling and heating, making it a practical choice throughout the year.

Across the UVHK series, the units are equipped with advanced filtration systems that purify the air, ensuring a healthier indoor environment. They are also designed for low noise levels, minimizing disturbance to occupants.

In summary, the CFM UVHK36MN, UVHK31MP, UVHK23MP, and UVHK29MN models provide a robust solution for climate control needs. With their inverter technology, energy efficiency, and user-friendly features, these units are ideal for a wide range of applications, ensuring comfort and satisfaction for users.