Maintenance and care
Replace light bulb
Use only BISSELL replacement bulbs in your
BISSELL PowerForce Turbo Bagless.
1.Unplug cleaner from electrical outlet.
2.Using a flat screwdriver, table knife or coin, insert into the slot on the right of the lens and gently push inner latch to the left, as shown, to remove the lens.
3.Remove the bulb from the socket by grasping bulb and pulling straight out. Install the new bulb by pushing it gently into the socket until the bulb snaps into place.
5.Reposition lens by inserting tab on left side and then pushing the right side back into place.
Clearing clog
Low suction, poor pickup or no suction may be due to a clog in the vacuum cleaner. If you notice a change in the sound of the vacuum motor or a reduction in the spinning action in the dirt container, check for clogs.
1.Unplug cleaner from electrical outlet.
2.Empty dirt container.
3.Check upper tank and primary separator for build up or clogs. Check to make sure primary separator is installed correctly. To unlock the primary separator, grasp the rim and turn toward the left. Pull straight down to remove. If the primary separator is missing or not locked into place, check and clear the tube in the center of the dirt container and properly install primary separator.
4.Remove the Twist ‘n Snap hose from the vacuum by turning to the left. Check the suction inlet, hose and hose wand for clogs. Remove any clogs from the hose using a long, narrow object such as a broomstick.
5.Check the foot hose for clogs. If needed, remove the screw attaching the hose wand base to the vacuum. Straighten the foot hose and unclog with a long, narrow object such as a broomstick.
6.If the clog persists, follow the instructions for checking the rotating floor brush on page 11 and inspect the air passageway for obstructions.
12 w w w . b i s s e l l . c o m
Primary Separator
Suction
Inlet
Hose Wand
Base
Air Passageway
10/14/08 2:40:50 PM