Before you call for service…
Troubleshooting Tips
Problem |
| Possible Causes | What To Do | |
|
|
|
|
|
Rumbling noise |
| Scale and sediment | ● Clean tank. | |
|
| in tank. |
| |
|
|
|
|
|
Relief valve |
| Pressure build up | ● This is an unacceptable condition and must be | |
producing popping |
| caused by thermal | corrected. Contact the water supplier or plumbing | |
noise or draining |
| expansion to a | contractor on how to correct this. Do not plug the | |
|
| closed system. | relief valve outlet. | |
|
|
|
|
|
Not enough or |
| Water usage may have | ● Wait for the water heater to recover after an abnormal | |
no hot water |
| exceeded the capacity | demand. | |
|
| of the water heater. |
| |
|
|
|
|
|
|
| Low gas pressure. | ● Check gas supply pressure and manifold pressure. | |
|
|
|
|
|
|
| The pilot may be out. | ● Check the pilot. If necessary, relight using the | |
|
|
|
| instructions in the “Lighting The Water Heater” section |
|
|
|
| of this manual. |
|
|
|
|
|
|
| The gas control (thermostat) | ● See the “Water Temperature Setting of The Water | |
|
|
| may be set too low. | Heater” section of this manual. |
|
|
|
|
|
|
| Leaking or open hot water | ● Make sure all faucets are closed. | |
|
| faucets. |
| |
|
|
|
| |
|
| Combustion Shutoff System | ● Contact a qualified service technician. | |
|
| tripped. |
| |
|
|
|
| |
Water is too hot |
| The gas control (thermostat) | ● See the “Water Temperature Setting of The Water | |
|
| is set too high. | Heater” section of this manual. | |
|
|
|
| |
|
| Gas control (thermostat). | ● Contact a qualified service technician to replace the | |
|
|
| Defective | gas control (thermostat). |
|
|
|
| |
Pilot Lights, but |
| Combustion Shutoff System | ● Contact a qualified service technician. | |
Burner will not |
| tripped. |
| |
stay lit |
|
|
|
|
|
|
|
|
|
!CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (gas control (thermostat)), burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.