GE GP Series, SG Series Operating the water heater, Safety Precautions, Water Temperature Setting

Page 17

Operating the water heater.

!CAUTION: Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time (generally two weeks or more). HYDROGEN GAS IS EXTREMELY FLAMMABLE!! To dissipate such gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen is present, there will be an unusual sound such as air escaping through the pipe as the water begins to flow. Do not smoke or use an open flame near the faucet at the time it is open.

Safety Precautions

Safety Instructions

Do turn off manual gas shut-off valve if water heater has been subjected to over heating, fire, flood, physical damage or if the gas supply fails to shut off.

Do Not turn on water heater unless it is completely filled with water.

Do Not turn on water heater if cold water supply shut-off valve is closed.

Do Not allow combustible materials such as newspaper, rags or mops to accumulate near water heater.

Do Not store or use gasoline or other flammable vapors and liquids, such as adhesives or paint thinner, in vicinity of this or any other appliance. If such flammables must be used, open doors and windows for ventilation, and all gas burning appliances in the vicinity should be shut off including their pilot burners, to avoid vapors lighting.

NOTICE: Flammable vapors can be drawn by air currents from surrounding areas to the water heater.

If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section, it is recommended that a qualified person or serviceman perform the work.

Installation Instructions Operating Instructions

!DANGER: Hotter water increases the Potential for Hot Water SCALDS. Households with small children, disabled, or elderly persons may require a 120°F or lower gas control (thermostat) setting to prevent contact with HOT water.

Water Temperature Setting

The temperature of the water in the water heater can be regulated by setting the temperature dial on the front of the gas control (thermostat).

Safety and energy conservation are factors to be considered when selecting the water temperature setting of the water heater’s gas control (thermostat(s)). The lower the temperature setting, the greater the savings in energy and operating costs.

To comply with safety regulations the gas control (thermostat) was set at its lowest setting before the water heater was shipped from the factory. The recommended starting point temperature is 120°F.

Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined in this manual and on the label located on the water heater near the gas control (thermostat).

Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines. Contact a licensed plumber or the local plumbing authority for further information. (See page 4 for more details).

The chart below may be used as a guide in determining the proper water temperature for your home.

Care and Cleaning Troubleshooting

Time/Temperature Relationship in Scalds

Water Temperature

Time To Produce a Serious Burn

120°F

More than 5 minutes

125°F

11/2 to 2 minutes

130°F

About 30 seconds

135°F

About 10 seconds

140°F

Less than 5 seconds

145°F

Less than 3 seconds

150°F

About 11/2 seconds

155°F

About 1 second

Table courtesy of Shriners Burn Institute

Tips Customer Service

17

Image 17
Contents Part No. AP13204-4 01/05 Pub. No -50103 JR To do so may result in an explosion or fireDo not try to light any appliance Installation Instructions Safety InformationCare and Cleaning Troubleshooting TipsInstall the Draft Hood and Properly Vent the Water HEATER… At its lowest setting Time/Temperature Relationship in ScaldsWas set Was shipped fromSafety Instructions Installation Customer Service Troubleshooting Tips Care and CleaningSafety Instructions Installing the water heaterTop View Alcove Top View ClosetInspect Shipment Customer ServiceCombustion and Ventilation Air Corrosive AtmospheresTroubleshooting Tips Customer Typical InstallationThermal Expansion Water Supply ConnectionsRelief Valve Care and Cleaning OperatingTo Fill the Water Heater CondensationPressure Testing the Gas Supply System Leak TestingGas Supply High AltitudeInstructions VentingInsulation Blankets During Installation of this water heater… Hot and Cold Pipe Insulation InstallationCare and Cleaning Troubleshooting Tips Customer Service Heat TrapsWater Supply Installation checklistWater Heater Location Requires water for space heating at Combination Potable and Space Heating ApplicationLighting the water heater. With SmartWater Ignition System Water Temperature Setting Safety PrecautionsTime/Temperature Relationship in Scalds Operating the water heaterCustomer Water Temperature Setting…Service Troubleshooting Tips Routine Preventative Maintenance Care and cleaning of the water heaterSafety Draining the Water HeaterBurner Inspection Venting System InspectionVacation and Extended Shut-Down Anode RodProblem Possible Causes What To Do Before you call for service…Scale and sediment Clean tank Tank Troubleshooting Tips Installation Instructions Instructions For Placing a Parts Order Replacement partsBurner Assembly Kit If you need service… Please place in envelope and mail to Water Heater Model Number Serial Number Model Number Serial Number