Safety Information

Safety Precautions . . . . . . 3, 4

Installation Instructions

Location

5

Water Connections

6

Electrical Connections

8

Operating Instructions

Safety Controls . . . . . . . . . . . 12 Water Temperature. . . . . . . . . 13

Care and Cleaning

Draining . . . . . . . . . . . . . . . . . . 14

Extended Shut-Down . . . . . . 14

Maintenance. . . . . . . . . . . . . . 14

Troubleshooting Tips

Before You Call

 

For Service

15

Customer Service

Parts List . . . . . . . . . . . . . . . . 16

Wiring Diagram . . . . . . . . . . . 18

Product Registration . . 19, 20

2

IMPORTANT!

Fill out and return the Consumer Product Registration Card that is in the back of this manual.

FOR YOUR RECORDS

Write the model and serial numbers here:

#

#

You can find them on a label on the appliance.

Staple sales slip or cancelled check here.

Proof of the original purchase date is needed to obtain service under the warranty.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your water heater properly. Just a little preventive care on your part can save you time and money over the life of your water heater.

You’ll find many answers to common problems in the Before You Call For Service section. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.

IF YOU NEED SERVICE

If you do need service, you can relax knowing help is only a phone call away. For service call 800-431-1549.

READ THE SAFETY INFORMATION

Your safety and the safety of others are very important. There are many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. Recognize this symbol

!as an indication of Important Safety Information! This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER”, “WARNING”, “CAUTION” or “NOTICE”.

These words mean:

!DANGER An imminently hazardous situation that will result in death or serious injury.

!WARNING A potentially hazardous situation that could result in death or serious injury and/or damage to property.

!CAUTION A potentially hazardous situation that may result in minor or moderate injury.

Notice:Attention is called to observe a specified procedure or maintain a specific condition.

Image 2
Contents Model GE Series Part No. AP12170-4 11/03 Pub. No -50012-4 11-03 JRCare and Cleaning Safety InformationInstallation Instructions Troubleshooting TipsTime/Temperature Relationship in Scalds ServiceTroubleshooting Tips Customer ServiceInstructions Installation Installing the water heaterLocal Installation Regulations LocationWater Supply Connections Typical Side Connect InstallationThermal Expansion To Fill the Water Heater Typical Top Connect InstallationRelief Valve Electrical Connections Branch Circuit Sizing and Wire Size GuideTips Care and Cleaning Operating CondensationInsulation Blankets Hot and Cold Pipe Insulation InstallationDo not cover the temperature and pressure relief valve Illustrations above, that best meetsHeat Trap Relief Valve Insulation InstallationInstructions Safety Instructions Water Heater Location Installation checklistWiring Water SupplyPress the red Reset button Safety PrecautionsSafety Controls Operating the water heaterIf adjustment is necessary… Water Temperature SettingTime/Temperature Relationship in Scalds Draining the Water Heater Care and cleaning of the water heaterRoutine Preventative Maintenance Vacation and Extended Shut-DownCold water inlet Before You Call For Service…Problem Possible Causes What To Do Top Connect Models Replacement PartsInstructions For Placing a Parts Order For 20-52 gallon models with single or double elementsCavity Insert Instructions Wiring diagrams Wiring Diagrams for Type-59T Therm-o-disc ThermostatsPlease place in envelope and mail to After mailing Model Number Serial NumberWater Heater Model Number Serial Number

GE30T06MAG, AP12170-4 specifications

The GE AP12170-4, also known as the GE30T06MAG, is a cutting-edge product designed to enhance efficiency and reliability in various industrial applications. This model has garnered attention due to its advanced features, robust technologies, and overall performance characteristics.

One of the standout features of the GE AP12170-4 is its high power capacity, which enables it to handle demanding loads in large industrial environments. The device is engineered to maintain continuous operation even under extreme conditions, making it ideal for critical infrastructures where downtime is not an option. Its durable construction is designed to withstand harsh environmental factors, ensuring longevity and consistent performance.

In terms of technology, the GE AP12170-4 integrates state-of-the-art control systems that facilitate precise monitoring and management of electrical loads. This technology allows users to optimize energy consumption while simultaneously safeguarding against overloads. The built-in diagnostics and data logging capabilities provide real-time insights into operational efficiency and can be crucial for predictive maintenance, reducing unexpected failures and operational costs.

Additionally, this model features advanced safety mechanisms, including surge protection and fault detection systems, which are essential for minimizing risks associated with electrical surges and other anomalies. This focus on safety extends to user-friendly interfaces, which simplify the operation and maintenance of the device. Operators can easily navigate through settings and troubleshoot potential issues, enhancing overall usability.

The GE AP12170-4 also incorporates flexible connectivity options, allowing it to integrate seamlessly into existing systems. Whether using legacy communication protocols or modern networks, users can enjoy versatile connectivity that enhances interoperability with other industrial equipment. This adaptability is vital for facilities undergoing digital transformation and seeking to improve operational efficiency.

Moreover, the design of the GE AP12170-4 emphasizes energy efficiency, contributing to lower operational costs and reduced environmental impact. By optimizing performance and reducing energy waste, it aligns with the growing demand for sustainable practices in industrial operations.

Overall, the GE AP12170-4, or GE30T06MAG, represents a blend of power, reliability, and advanced technology. Its comprehensive features equip industries to meet the challenges of modern operations while prioritizing safety, efficiency, and sustainability. Whether in manufacturing, utility, or larger infrastructure projects, this model stands out as a versatile solution for meeting the demands of today’s industrial landscape.