GE AP12169-5, GE Series Typical Installation, Relief Valve, Tips Customer Service

Page 7

Typical Installation

Recommended

 

Union

 

Unions

Temperature &

heat trap

 

 

 

 

pressure relief

6minimum

 

Anode

 

 

valve

 

 

 

 

 

Hot water outlet

 

Water

 

 

 

to fixtures

 

Heater

 

 

 

Temperature &

 

Jacket

 

 

 

 

 

 

 

Power supply

pressure relief

 

Jacket

Shut-off valve

 

valve

 

access

 

 

cord 21/2 gal.

To cold water

 

panel

Cold water supply

 

models only

 

 

 

Drain valve*

supply

 

 

Relief

 

Shut-off valve

 

Opening

 

 

 

valve

 

 

Relief

 

for 1/2

discharge

 

Jacket access

 

or 3/4

line

 

valve

 

Water

panel

 

electrical

 

discharge

 

 

 

 

fitting

 

Heater

Auxiliary

line to

 

 

 

 

 

Jacket

catch pan

suitable

Drain valve

 

 

(use only copper

6

Auxiliary catch

 

open

 

 

(not supplied)

conductors)

 

pan drain line

Hot water

drain

 

 

 

 

 

outlet

 

6air gap

 

Suitable open drain

 

Auxiliary catch pan

(to fixtures)

 

 

 

 

 

Auxiliary catch pan

Suitable open drain

 

 

 

 

*The drain valve is located below and to the right of jacket access panel and is

drain line

 

 

not visible in this view.

 

 

 

 

Vacuum Relief Valve

 

 

 

 

(Not Supplied)

 

 

If required, install per local codes

and valve manufacturer’s

instructions.

A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must remain installed in the opening provided and marked for the purpose on the water heater. No valve of any type should be installed between the relief valve and the tank. Local codes shall govern the installation of relief valves.

Safety Instructions Installation Instructions Operating Instructions Care and Cleaning Troubleshooting

WARNING: The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate.

Relief Valve

The Btuh rating of the relief valve must not be less than the input rating of the water heater as indicated on the rating label located on the front of the heater (1 watt=3.412 Btuh).

Connect the outlet of the relief valve to a suitable open drain so that the discharge water cannot contact live electrical parts or persons and to eliminate potential water damage.

Piping used should be of a type approved for hot water distribution. The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage (by gravity) of the relief valve and discharge line. The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction or reducer coupling should be installed in the discharge line.

Tips Customer Service

7

Image 7
Contents Manufactured under trademark license by Model GE SeriesDefects or other reproductive harm Troubleshooting Tips Safety InformationInstallation Instructions Care and CleaningService Time/Temperature Relationship in ScaldsCustomer Service Troubleshooting TipsLocal Installation Regulations Installing the water heaterLocation Thermal Expansion Instructions Safety InstructionsCustomer Service Troubleshooting Tips Inspect ShipmentTips Customer Service Typical InstallationRelief Valve Condensation To Fill the Water HeaterElectrical Connections Care and Cleaning Troubleshooting Tips Customer Service Branch Circuit Sizing and Wire Size GuideInsulation Blankets Relief Valve Insulation Installation Hot and Cold Pipe Insulation InstallationHeat Traps Water Supply Installation checklistWiring Water Heater LocationEmergency Instructions Safety PrecautionsSafety Controls Operating the water heaterTime/Temperature Relationship in Scalds Water Temperature SettingIf adjustment is necessary… Draining the Water Heater Care and cleaning of the water heaterRoutine Preventative Maintenance Installation Instructions SafetyProblem Possible Causes What To Do Before You Call For Service…Cold water inlet 21/2 Gallon Models Replacement PartsTips Care and Cleaning Operating Instructions Installation Instructions For Placing a Parts OrderPlug Connected cord set only Wiring diagramsWiring Diagrams for Type-59T Therm-o-disc Thermostats Installation Instructions Operating InstructionsInstallation Instructions Please place in envelope and mail to Water Heater Model Number Serial Number Model Number Serial NumberAfter mailing

AP12169-5, GE Series specifications

The GE Series AP12169-5 represents a robust and versatile line of products designed by General Electric to cater to the diverse needs of modern industries. These units are characterized by their high efficiency, advanced technology, and user-friendly design, making them ideal for various applications, including industrial automation, HVAC systems, and power generation.

One of the standout features of the GE Series AP12169-5 is its energy efficiency. The product incorporates state-of-the-art energy-saving technologies that significantly reduce power consumption while optimizing performance. This aspect not only contributes to lower operational costs but also supports sustainability initiatives by minimizing the carbon footprint.

In addition to energy efficiency, the AP12169-5 series is equipped with advanced monitoring and control capabilities. These features allow for real-time performance analysis, thereby enabling operators to make informed decisions and implement timely adjustments. The built-in diagnostic tools assist in predictive maintenance, reducing downtime and enhancing the longevity of the equipment.

The GE Series AP12169-5 emphasizes ease of integration within existing systems. It supports various communication protocols, ensuring compatibility with a wide range of devices and frameworks. This flexibility facilitates seamless upgrades and expansions, making it an attractive option for businesses looking to enhance their operational efficiency without overhauling their entire infrastructure.

Another notable characteristic of the GE Series AP12169-5 is its durability. Built with high-quality materials and utilizing advanced manufacturing techniques, these units are designed to withstand harsh environments and demanding conditions. This reliability ensures continuous operation, which is crucial in industries where downtime can result in significant losses.

The user-friendly interface of the AP12169-5 also deserves mention. Its intuitive controls and comprehensive display simplify the operation and monitoring processes, making it accessible for personnel with varying levels of technical expertise. This feature translates to less training time and quicker adaptation to the system.

In summary, the GE Series AP12169-5 exemplifies a harmonious blend of efficiency, advanced technology, and robust durability. With its focus on energy savings, ease of integration, real-time monitoring, and user-friendly design, this product series is well-positioned to meet the evolving demands of industries worldwide. General Electric continues to demonstrate its commitment to innovation and excellence through the development of solutions that drive productivity and sustainability in the modern industrial landscape.