DANGER!

WATER TEMPERATURE SETTING

Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heater’s thermostat. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on the water heater near the thermostat access panel.

Safety Instructions Installation

!D A N G E R

HOT

BURN

Water temperature over 125°F can cause severe burns instantly or death from scalds.

Children, disabled and elderly are at highest risk of being scalded.

Time/Temperature Relationship in Scalds

Water Temperature

Time To Produce a Serious Burn

120°F

More than 5 minutes

125°F

11/2 to 2 minutes

130°f

About 30 seconds

135°F

About 10 seconds

140°F

Less than 5 seconds

145°F

Less than 3 seconds

150°F

About 11/2 seconds

155°F

About 1 second

Table courtesy of Shriners Burn Institute

The chart shown above may be used as a guide in determining the proper water temperature for your home.

NOTICE: Households with small children, disabled, or elderly persons may require a 120°F or lower thermostat setting to prevent contact with “HOT” water.

The temperature of the water in the heater is regulated by the adjustable surface mounted thermostat(s) located behind the jacket access panel(s). Dual element heaters have two thermostats. To comply with safety regulations the thermostat(s) were set at 120°F before the water heater was shipped from the factory.

Instructions Operating Instructions Care and Cleaning

See instruction manual before setting temperature at water heater.

Feel water before bathing or showering.

Temperature limiting valves are available, see manual.

NOTICE: Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in

Reset button

T

R

E

E

S

S

E

R

T E

Thermostat

 

 

dial pointer

 

 

 

150°F

90°F

 

(66°C)

(32°C)

 

125°F(52°C)

 

TURN OFF

 

POWER

 

BEFORE

Thermostat

SERVICING

 

 

protective

 

 

cover

 

 

The illustration at the left shows the temperature adjustment dial used for setting the water temperature.

Refer to the Operating Instructions in this manual for detailed instructions in how to adjust the thermostat(s).

Troubleshooting Tips Customer

branch water lines. Contact a licensed plumber or the local plumbing authority for further information.

DANGER: Hotter water increases the potential for Hot Water SCALDS.

Service

3

Image 3
Contents Model GE Series Manufactured under trademark license byDefects or other reproductive harm Troubleshooting Tips Safety InformationInstallation Instructions Care and CleaningService Time/Temperature Relationship in ScaldsCustomer Service Troubleshooting TipsInstalling the water heater Local Installation RegulationsLocation Thermal Expansion Instructions Safety InstructionsCustomer Service Troubleshooting Tips Inspect ShipmentTypical Installation Tips Customer ServiceRelief Valve To Fill the Water Heater CondensationElectrical Connections Branch Circuit Sizing and Wire Size Guide Care and Cleaning Troubleshooting Tips Customer ServiceInsulation Blankets Hot and Cold Pipe Insulation Installation Relief Valve Insulation InstallationHeat Traps Water Supply Installation checklistWiring Water Heater LocationEmergency Instructions Safety PrecautionsSafety Controls Operating the water heaterWater Temperature Setting Time/Temperature Relationship in ScaldsIf adjustment is necessary… Draining the Water Heater Care and cleaning of the water heaterRoutine Preventative Maintenance Installation Instructions SafetyBefore You Call For Service… Problem Possible Causes What To DoCold water inlet 21/2 Gallon Models Replacement PartsTips Care and Cleaning Operating Instructions Installation Instructions For Placing a Parts OrderPlug Connected cord set only Wiring diagramsWiring Diagrams for Type-59T Therm-o-disc Thermostats Installation Instructions Operating InstructionsInstallation Instructions Please place in envelope and mail to Model Number Serial Number Water Heater Model Number Serial NumberAfter mailing

AP12169-5, GE Series specifications

The GE Series AP12169-5 represents a robust and versatile line of products designed by General Electric to cater to the diverse needs of modern industries. These units are characterized by their high efficiency, advanced technology, and user-friendly design, making them ideal for various applications, including industrial automation, HVAC systems, and power generation.

One of the standout features of the GE Series AP12169-5 is its energy efficiency. The product incorporates state-of-the-art energy-saving technologies that significantly reduce power consumption while optimizing performance. This aspect not only contributes to lower operational costs but also supports sustainability initiatives by minimizing the carbon footprint.

In addition to energy efficiency, the AP12169-5 series is equipped with advanced monitoring and control capabilities. These features allow for real-time performance analysis, thereby enabling operators to make informed decisions and implement timely adjustments. The built-in diagnostic tools assist in predictive maintenance, reducing downtime and enhancing the longevity of the equipment.

The GE Series AP12169-5 emphasizes ease of integration within existing systems. It supports various communication protocols, ensuring compatibility with a wide range of devices and frameworks. This flexibility facilitates seamless upgrades and expansions, making it an attractive option for businesses looking to enhance their operational efficiency without overhauling their entire infrastructure.

Another notable characteristic of the GE Series AP12169-5 is its durability. Built with high-quality materials and utilizing advanced manufacturing techniques, these units are designed to withstand harsh environments and demanding conditions. This reliability ensures continuous operation, which is crucial in industries where downtime can result in significant losses.

The user-friendly interface of the AP12169-5 also deserves mention. Its intuitive controls and comprehensive display simplify the operation and monitoring processes, making it accessible for personnel with varying levels of technical expertise. This feature translates to less training time and quicker adaptation to the system.

In summary, the GE Series AP12169-5 exemplifies a harmonious blend of efficiency, advanced technology, and robust durability. With its focus on energy savings, ease of integration, real-time monitoring, and user-friendly design, this product series is well-positioned to meet the evolving demands of industries worldwide. General Electric continues to demonstrate its commitment to innovation and excellence through the development of solutions that drive productivity and sustainability in the modern industrial landscape.