!General Safety Precautions

Be sure to read and understand the entire Use & Care Manual before attempting to install or operate this water heater. Pay particular attention to the following General Safety Precautions. Failure to follow these warnings could result in a fire or explosion, causing property damage, bodily injury or death . Should you have any problems understanding the instructions in this manual, STOP, and get help from a qualified installer or service technician or the gas supplier.

!WARNING

!DANGER

Gasoline, as well as other flammable materials and liquids (adhesives, solvents, etc.), and the vapors they produce, are extremely dangerous. DO NOT handle, use or store gasoline or other flammable or combustible materials any- where near or in the vicinity of a water heater. Be sure to read and follow the warning label pictured below and other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in property dam- age, bodily injury, or death.

!DANGER

Failure to properly vent the water heater to the outdoors as outlined in the Venting Section of this manual can result in unsafe operation of the water heater. To avoid the risk of fire, explosion, or asphyxiation from carbon monoxide, never operate this water heater unless it is properly vented and has an adequate air supply for proper operation. Be sure to inspect the vent system for proper installation at initial start-up; and at least annually thereafter. Refer to Maintenance section of this manual for more information regarding vent system inspections.

!D A N G E R

FLAMMABLES

FlammableVapors

LIQUEFIED PETROLEUM MODELS — Propane, or LP gas, must be used with great caution.

It is heavier than air and will collect first in lower areas making it hard to detect at nose level.

Make sure to look and smell for LP leaks before attempting to light appliance. Use a soapy solution to check all gas fittings and connections. Bubbling at a connection indicates a leak that must be corrected. When smelling to detect an LP leak, be sure to sniff near the floor too.

Gas detectors are recommended in LP applications and their installation should be in accordance with the manufacturer's recommendations and/or local laws, rules, regulations or customs.

It is recommended that more than one method be used to detect leaks in LP applications.

IF LP GAS IS PRESENT OR SUSPECTED:

DO NOT attempt to find the cause yourself;

DO NOT try to light any appliance;

DO NOT touch any electrical switch;

DO NOT use any phone in your building.

Leave the house immediately and make sure your fam- ily and pets leave also.

Leave the doors open for ventilation and contact the gas supplier, a qualified service agency or the fire department.

Keep the area clear until the service call has been made, the leak is corrected, and a qualified agency has determined the area to be safe.

!WARNING

Both LP and natural gas have an odorant added to help detection. Some people may not physically be able to smell or recognize this odorant. If unsure or unfamiliar about the smell associated with LP or natural gas, ask the gas supplier. Other conditions, such as "Odorant Fade", which causes the odorant to "fade", or diminish in inten-

!Vapors from flammable liquids will explode and catch fire causing death or severe burns.

Do not use or store flammable products such as gasoline, solvents or adhesives in the same room or area near the water heater.

Keep flammable products:

1.far away from heater,

2.in approved containers,

3.tightly closed and

4.out of children's reach.

Water heater has a main burner and pilot flame. The pilot flame:

1.which can come on at any time and

2.will ignite flammable

vapors.

Vapors:

1.cannot be seen,

2.are heavier than air,

3.go a long way on the floor and

4.can be carried from other rooms to the pilot flame by air currents.

sity can also hide or camouflage a gas leak.

!DANGER

Water heaters utilizing Liquefied Petroleum gas (LP) are different from natural gas models. A natural gas heater will not function safely on LP gas and vice versa. No attempt should ever be made to convert a heater from natural gas to LP gas. To avoid possible equipment damage, personal injury or fire: DO NOT connect this water heater to a fuel type not in accordance with unit data plate. Propane for propane units. Natural gas for natural gas units. These

Installation:

are at least 18" above the

Do not install water heater

floor.This will reduce, but not

where flammable products will

eliminate, the risk of vapors

be stored or used unless the

being ignited by the main

main burner and pilot flames

burner or pilot flame.

Read and follow water heater warnings and instructions. If owners manual is missing, contact the retailer or manufacturer.

units are not certified for any other type fuel.

!WARNING

LP appliances should not be installed below-grade (for example, in a basement) if such installation is prohibited by federal, state and/or local laws, rules, regulations or cus- toms.

Image 4
Contents USE & Care Manual Read the Safety Information General Safety Precautions N G E RN G E R Sity can also hide or camouflage a gas leakLocal Installation Regulations IntroductionInstallation Typical Installation Drawing Venting Minimum and Maximum Vent Lengths Additional Considerations See Figure BuildingHorizontal Vent Terminal Location Cleaner-Primer and Medium Body Solvent Cement Installation Check List For Proper InstallationForyoursafetyreadbeforeoperating OperationFor Your Safety Read Before Operating Safety Precautions HoneywellWhite-RodgersMaintenance Emergency ShutdownVERIFY PROPER OPERATION AFTER SERVICING System Sentinel Diagnostic System PowerSystem SentinelTroubleshooting Guide POWER LEDTHERMOSTAT LED IGNITION LED PILOT VALVE LED ECO LED MAIN VALVE LEDReplacement Parts Instructions For Placing a Parts OrderWiring and Schematic Diagrams 120VFY PROPER OPERATION AFTER SERVICING How to Obtain Service Assistance

Commercial Power Direct Vent Water heater specifications

The Rheem Commercial Power Direct Vent Water Heater is engineered to meet the demanding needs of commercial applications, providing reliable and efficient hot water for various business environments. With a focus on performance, efficiency, and durability, this water heater stands out in the competitive landscape of commercial water heating solutions.

One of the key features of the Rheem Commercial Power Direct Vent Water Heater is its direct vent capability. This innovative design allows for installation in confined spaces while optimizing exhaust methods. The direct vent system enables the heater to draw air from outside the building for combustion, ensuring safe operation, reducing risk of backdraft, and maintaining indoor air quality.

The water heater is powered by either natural gas or propane, accommodating diverse fuel supply preferences. With a range of storage capacities, it can cater to small and large businesses, from restaurants to industrial facilities. The product’s high recovery rate ensures that it can meet peak hot water demands, making it an ideal solution for facilities with fluctuating hot water usage.

Equipped with advanced technology, the Rheem Commercial Power Direct Vent Water Heater features a state-of-the-art electronic control system that allows for easy temperature adjustments and monitoring. This interface ensures precise temperature control, so businesses can consistently deliver hot water at the required temperatures.

Durability is a hallmark of this water heater, which incorporates premium-grade components and materials. The tank is constructed with a glass-lined steel design that enhances resistance to corrosion, while also supporting longevity. Additionally, it features robust insulation that reduces heat loss, improving energy efficiency and lowering operating costs.

Another notable characteristic is the inclusion of a high-efficiency burner that maximizes fuel utilization, promoting energy savings and reducing emissions. The heater also complies with various energy standards, making it a sustainable choice for environmentally conscious businesses.

Installation and maintenance are streamlined with the Rheem Commercial Power Direct Vent Water Heater. Its compact design and versatile venting options allow for flexible placement. Furthermore, the unit is designed for easier access to critical components, making routine service and maintenance uncomplicated.

Overall, the Rheem Commercial Power Direct Vent Water Heater represents a fusion of efficiency, ease of use, and advanced technology, making it a smart investment for commercial establishments needing reliable hot water solutions. Whether in kitchens, manufacturing plants, or commercial offices, this water heater is engineered to deliver performance and peace of mind.