Rheem Commercial Power Direct Vent Water heater installation instructions Thermostat Led

Page 21

“System Sentinel”Troubleshooting Guide

Section 2... the “THERMOSTAT” LED

NO

 

Is the “THERMOSTAT” LED Illuminated?

 

 

 

 

 

 

 

 

 

 

 

Ensure that power is being supplied to

 

YES

the water heater. Refer to “Section 1...the

 

 

POWER LED”in thisTroubleshooting Guide,

 

 

and correct if necessary. Is the “THERMO-

 

 

STAT LED”now illuminated.

 

 

 

NO

 

 

YES

 

 

 

Is Thermostat set at a tempera-

 

 

Adjust

ture higher than the water tem-

NO

 

Thermostat to a higher setting.

perature in tank?

 

 

 

Is Thermostat LED now illumi-

 

 

 

 

 

 

nated?

YES

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

Ensure that power is being supplied to

Is 24 VAC

 

 

 

 

the water heater. Refer to “Section 1...the

power present

at Yellow Wire

NO

 

POWER LED”in thisTroubleshooting Guide,

Terminal insideThermostat?

 

 

and correct if necessary. Is the “THERMO-

YES

 

 

STAT LED”now illuminated.

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

Is 24 VAC power present at

 

 

 

Blue Wire Terminal inside Ther-

YES

 

 

mostat?

 

 

 

NO

Thermostat is

defective or out of calibration and must be replaced.

YES

Thermostat is calling for heat, and 24VAC power.

YES

!CAUTION

Label all wires prior to disconnection when servicing controls.Wiring errors can cause improper and dangerous operation. VERIFY PROP-

ER OPERATION AFTER SERVICING!

21

Image 21 Contents
USE & Care Manual Read the Safety Information N G E R General Safety PrecautionsSity can also hide or camouflage a gas leak N G E RIntroduction Local Installation RegulationsInstallation Typical Installation Drawing Venting Minimum and Maximum Vent Lengths Building Additional Considerations See FigureHorizontal Vent Terminal Location Cleaner-Primer and Medium Body Solvent Cement For Proper Installation Installation Check ListOperation ForyoursafetyreadbeforeoperatingFor Your Safety Read Before Operating HoneywellWhite-Rodgers Safety PrecautionsEmergency Shutdown MaintenanceVERIFY PROPER OPERATION AFTER SERVICING Power System Sentinel Diagnostic SystemPOWER LED System SentinelTroubleshooting GuideTHERMOSTAT LED IGNITION LED PILOT VALVE LED MAIN VALVE LED ECO LEDInstructions For Placing a Parts Order Replacement Parts120V Wiring and Schematic DiagramsFY PROPER OPERATION AFTER SERVICING How to Obtain Service Assistance