3.0Commissioning of solar controller

3.1Overview of display and operating elements (see Fig. 7).

Number

Description

1

Display with graphic symbols

2

Control button scroll upwards / +

3

Control button exit / break-off

4

Control button scroll downwards / –

5

Control button choice / confirmation

3.1.1 Explanation of graphic symbols

Graphic symbol

Description

Indicationin operation

 

 

 

Main Menu

Menu "Info"

Menu "Programming"

Menu "Manual operation"

Menu "Basic adjustment"

When symbol flashes it is possible for it to be selected. If that symbol is chosen by pressing the button, the symbol remains static (not flashing).

Graphic symbol

 

Description

Indicationin operation

 

 

Indicator values

 

dT

 

Temperature difference

 

 

 

min

 

Min value

Appears when minimum values are indicated

max

 

Max value

Appears when maximum values are indicated

min

 

Timeframe 1 start

Appears when the differential controller is active

0:00

 

 

(timeframe 1-3) or tube collector is active (timeframe 4)

1

 

Timeframe 1 stop

Appears when the differential controller is active

Max

 

23:59

 

 

(timeframe 1-3) or tube collector is active (timeframe 4)

1

 

 

 

 

 

 

 

 

 

5 x 7 segment display.

Display of all values, display flashes when

 

 

Presentation of figures 00000 to 99999

a value is changed

ºC

 

Temperature in Celsius

 

K

 

Temperature difference in Kelvin

 

h

 

Operating hours

 

kWh

 

Productivity indication in kWh

 

Potterton Solar - Solar Thermal Domestic Hot Water System

7

Image 7 Contents
Commissioning, Maintenance & Servicing Guide Index IndexPotterton Solar Solar Thermal Domestic Hot Water System Commissioning General Commissioning of systemFilling the pipework Flushing the pipeworkFilling pump Filter Solar fluid Ensure the solar primary system is free Setting the system pressureCheck pressure in the solar primary PipeworkApprox Checking and adjusting the flow rateInstallation of the thermal insulation Commissioning of hydraulic stationMax Commissioning of solar controllerOverview of display and operating elements see Fig Number DescriptionSolar circulation pump StatusindicationInput value can be either Button 65COperatingmenu Installer or service engineerOverviewConstructionof menu structure Info Program Manualoperation Basic settingStates are shown Reset in the following way Choose the value with buttonsResetpossible MenuInfoMenuProgramming Description Valuerange Defaults= off MenuManual operationHours and the automatic regulation is activated again Indication DescriptionParameter/ value MenuBasic adjustmentIndication Description Value Factory Set-upSystems withtwostoragecylinders Contr ller functionsGeneral controlerfunctions Cylinder heatingby solar primarysystem14Thermostat heating Rotational speedregulation15Thermostat cooling 17Tubecollector 16TemperaturedifferencecontrolSensor monitoring Collector protection / Re-cooling Flow monitoringSystemprotection function Operatinghoursmeter Frost protectionPump is 5 minutes Energyproductivity measurementSolar Collector Panels SolarDifferentialTemperatureControllerGeneral Commissioning Hydraulic StationDate Servicing and maintenance recordBar Check solar primary system flow rate Check condition of all pipeworkSolar fluid concentrations MaintenanceCylinder Refer to manufacturers documentationSuggested measures to rectify Fault findingSolar differential temperature controller and will be When the system runs if visibleYES Resistance table PT1000Pump symbol on controller rotates But pump does not operate Spares Description CodeNo Spare partsWhen callingheateamyoumusthavethe following WarrantyStandard Warranty Terms & Conditions What you need to do if youexperiencea problemwithWarranty We are closed Christmas Day and New Years Day Potterton