Bunn service manual Tank Heater FMD-1 shown & FMD-2, Main Harness Thermostat

Page 37

SERVICE (cont.)

TANK HEATER - FMD-1 (shown) & FMD-2 (cont.)

NOTE - If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath.

Removal and Replacement:

1.Disconnect the dispenser from the power source.

2.Disconnect the water supply tube on the tank lid.

3.Disconnect the black wires on the limit thermstat.

4.Disconnect the black wire and the white or red wire from the tank heater terminals.

5.Disconnect the pink wire from the liquid level probe and the green wire from the tank.

6.Remove the thermostat capillary bulb by firmly pulling-up on the capillary at the tank lid. This will disengage the grommet from the tank lid.

7.Remove the ten #8-32 nuts securing the tank lid to the tank.

8.Remove tank lid with limit thermostat, liquid level probe and tank heater as an assembly.

9.Remove the two hex nuts securing the tank heater to the tank lid. Remove tank heater with gaskets and discard.

10.Install new tank heater with gaskets on the tank lid and secure with two hex nuts.

11.Install tank lid with limit thermostat, liquid level probe and tank heater on the tank and secure with ten #8-32 hex nuts.

12.Connect water inlet line to the tank lid.

13.Reconnect the black wires to limit thermostat, the pink wire to the liquid level probe and the green wire to the tank. Refer to the limit thermostat and the liquid level board and probe sections in this manual when reconnecting wires.

14.Refer to Fig. 40 when reconnecting the wires to the tank heater.

WHI or RED to

BLK to Limit

Main Harness

Thermostat

FIG. 40 TANK HEATER TERMINALS

P1218

 

 

 

TANK HEATER SWITCH - FMD-1 (shown) & FMD-2

P1665

FIG. 41 TANK HEATER SWITCH

Location:

The tank heater switch located inside the dis- penser on the upper right of the front panel.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Disconnect the black wires from the main wiring harness.

3.With the switch in the “ON” lower position check for continuity between the center and the upper terminal. With the switch in the “OFF” upper posi- tion no continuity should be present between center and upper terminals.

If continuity is present as described, the tank heater “ON/OFF” switch is operating properly.

If continuity is not present as described, replace the switch.

Removal and Replacement:

1.Remove the switch mounting nut on the front of the front panel.

2.Remove switch with wires attached from the rear of the front panel.

3.Remove the wires from the switch terminals and discard switch.

4.Connect the wires to the new switch, refer to Fig. 42.

5.Push new switch through hole in the front panel and secure with facenut.

37

29112 101598

 

Image 37
Contents BUNNFMD-1 FMD-2 Introduction WarrantyUser Notices FMD-1 FMD-2FMD-1 only 00656.000028368.0001 Electrical Requirements Initial SET-UPElectrical HOOK-UP Plumbing RequirementsInitial Fill & Heat Rinse Timer FMD-2 onlyLiquid Level Control Running a Rinse SequenceAdjustments CleaningHopper Motor Speed Adjustment FMD-1 Cold Beverage SET-UP Optional FMD-2 onlyDraining the HOT Water Tank Problem TroubleshootingProduct will not dispense Probable CauseProbable Cause Remedy Stat for testing procedures. See Problem Probable CauseFMD-1 SeeProblem Probable Cause Remedy Dispenser is making unusual Refer to Service Lamp, see page 28 for lamp replacementComponent Access ServiceContents Auger Drive Components FMD-1Hopper Lid Retainer Clip Hopper AssemblySpacer Auger Motor Hopper Base Dust Seal Washer Retainer Clip Ing panelTo the rear of the auger motor mounting panel Auger Drive Components FMD-1Auger Drive Components FMD-2 Hopper Hopper Assy Remove dust seal 17 from auger motor Disconnect the wires from the auger motor 16 to be removedRemove auger motor and discard Location Ballast FMD-1 & FMD-2Thermostat Terminals Control Board FMD-2 onlyService Dispense Switch Dispense Switchs FMD-1 & FMD-2 FAN FMD-1 & FMD-2 Dispense Switch Terminals P1449FMD-2 Whipper Motor Terminals P1221 Frother and Whipper Motor FMD-1 shown & FMD-2Hopper Drive Board Hopper Drive Board FMD-1 onlyHopper Drive Board Terminals Hopper Drive Board FMD-1 onlyDoor Assy Upper Panel Lamp Holders Lower Panel Lamp Replacement Refer to FigAs assembly Lamp Replacement Refer toLamp Starter and Socket Refer to Location Level Control Board and Level Probe FMD-1 onlyLevel Control Board and Level Probe FMD-1 only Reconnect the violet wire to terminalLocation RINSE/RUN Switch FMD-1WHI/RED to RINSE/RUN Switch FMD-2BLK from Main Harness WHI/BRN to YEL to Control Board J2-3 Cold Water Solenoid Valve Solenoid Valve Cold Water OPTIONALFMD-2 onlyFMD-1 Solenoid Valve Dispense FMD-1 & FMD-2 Tank Heater Solenoid Valve Inlet FMD-1 & FMD-2Main Harness Thermostat Tank Heater FMD-1 shown & FMD-2WHI/GRN T7 WHI/BLK T12 Transformer FMD-2 onlySingle Phase Schematic Wiring Diagram FMD-1Schematic Wiring Diagram FMD-2
Related manuals
Manual 8 pages 61.25 Kb

FMD-2, FMD-1 specifications

The Bunn FMD-2 is an advanced coffee dispensing machine designed for high-traffic environments, such as cafés, restaurants, and convenience stores. This commercial coffee equipment stands out for its reliability, efficiency, and user-friendly features, making it a preferred choice among coffee retailers.

A standout feature of the FMD-2 is its dual coffee bean hopper system, which allows for the storage and dispensing of two different coffee blends simultaneously. This versatility provides establishments the opportunity to cater to varying customer preferences, whether they prefer a robust espresso or a smooth medium roast. The hoppers can hold a significant amount of coffee beans, ensuring that the machine can keep up with high demand without the need for frequent refilling.

The FMD-2 incorporates state-of-the-art brewing technology, including the ability to brew coffee quickly while preserving the essential flavor characteristics of the beans. Its precision brewing process ensures consistency in taste and quality, which is crucial for customer satisfaction in a commercial setting. The machine is equipped with adjustable brew times and temperatures, allowing operators to fine-tune the brewing process according to specific coffee styles or customer preferences.

Another notable characteristic of the Bunn FMD-2 is its digital interface, which features an intuitive touchscreen display. This modern interface simplifies the operation of the machine, enabling baristas and staff to quickly train and adapt to its functionalities. The display provides real-time feedback on brewing status, maintenance reminders, and settings adjustments, making it easier to ensure optimal performance and reduce downtime.

In addition to its user-friendly design, the Bunn FMD-2 is constructed for durability. Its stainless steel exterior not only enhances its aesthetic appeal but also ensures that it can withstand the rigors of daily use in a bustling environment. The machine is designed with easy maintenance in mind, allowing for straightforward cleaning and servicing to keep it operating at peak performance.

Overall, the Bunn FMD-2 is a versatile, reliable, and innovative coffee dispensing solution that meets the demands of today’s coffee enthusiasts. With its dual hopper system, precision brewing technology, and user-friendly interface, it’s an ideal choice for any establishment looking to elevate their coffee offerings and enhance customer experience.