Burnham 40A, AL-26A, 53A, 79A manual General Information, Table of Contents

Page 3

I. General Information

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Read and understand the entire manual before attempting installation, start-up operation, or service. Installation and service must be performed only by an experienced, skilled installer or service agency.

Installation is not complete unless a pressure and temperature relief valve is installed into the side of the water heater. See Piping Section of this manual for details.

This water heater contains very hot water under high pressure. Do not unscrew any pipe fittings nor attempt to disconnect any components of this water heater without positively assuring the water is cool and has no pressure. Always wear protective clothing and equipment when installing, starting up or servicing this water heater to prevent scald injuries. Do not rely on the pressure and temperature gauges to determine the temperature and pressure of the water heater. This water heater contains components which become very hot when the boiler is operating. Do not touch any components unless they are cool.

Water heater materials of construction contain urethane, heavy metals and/or other toxic or harmful substances which can cause death or serious injury and which are known to the state of California to cause cancer, birth defects and other reproductive harm. Always use proper safety clothing, respirators and equipment when servicing or working nearby this water heater.

Failure to follow all instructions in the proper order can cause personal injury or death. Read all instructions, including all those contained in component manufacturers' manuals which are provided with the water heater before installing, starting up, operating, maintaining or servicing.

NOTICE

The Alliance water heater must be installed with a pressure and temperature relief valve. The valve is not supplied with the water heater and must be provided by the installer.

Table of Contents

Section I - General Information

3

Section V - Operation

16

Ratings, Capacities, Weights, & Dimensions

4

Section VI - Service Instructions

17

Section II - Pre-Installation

5

Section VII - Trouble Shooting

18

Section III - Piping

8

Section VIII - Repair Parts

19

Section IV - Electrical

15

Warranty

Back Cover

3

Image 3
Contents INDIRECT-FIRED Water Heaters For Single Water Heater InstallationsT IC E General Information Table of ContentsAlliance Water Heater Dimension Inches Important Decisions Required Before Installation II. Pre-InstallationDomestic Hot Water Priority Two options are Removal of Existing Domestic Water Heating System Hot Water and Relief Valve Piping III. PipingCold Water Supply Piping Water Boiler Piping with Zone Valves and a Boiler Bypass Page Page Page Page IV. Electrical Operation VI. Service Instructions Problem Cause Solution VII. Trouble ShootingVIII. Repair Parts Urnham Corporation Regional Offices Inspection / Service Schedule

53A, 40A, 79A, AL-26A specifications

The Burnham line of engineering includes several models known for their efficiency, advanced technology, and adaptability to various applications. Notably, the Burnham 40A, 53A, AL-26A, and 79A are among the most respected in the industry, each offering distinct features tailored to meet the needs of residential and commercial users.

The Burnham 40A is a versatile boiler designed for small to medium-sized applications. One of its main features is its efficient heat exchange system, which maximizes the transfer of heat while minimizing energy consumption. This model incorporates advanced burners that provide uniform heating and enhanced fuel efficiency, ensuring lower operational costs for users. Additionally, it is engineered to be compatible with different fuel types including natural gas and propane, providing versatility and flexibility for installations.

The Burnham 53A, on the other hand, emphasizes durability and reliability. This model is built with a robust steel construction, designed to withstand harsh conditions while maintaining a low maintenance profile. The hybrid design allows for a more significant heat output, making it suitable for larger spaces. Moreover, its integrated control system offers precise temperature management, essential for both comfort and energy savings.

In the portfolio, the AL-26A stands out due to its advanced automation technology. This model features smart control mechanisms that facilitate easy monitoring and adjustments. Users can optimize performance through a user-friendly interface, attracting those who value convenience. Furthermore, the AL-26A has enhanced safety features that ensure reliable operation, reducing the risk of malfunctions.

Finally, the Burnham 79A is a powerhouse, specifically engineered for heavy-duty commercial applications. With high-capacity output, it is capable of meeting demanding heating requirements without sacrificing efficiency. This model incorporates sophisticated insulation technologies that reduce heat loss, thus promoting energy conservation. Its design ensures ease of access for maintenance, thereby extending the lifecycle of the boiler.

In conclusion, the Burnham 40A, 53A, AL-26A, and 79A are exemplary models that reflect the brand's commitment to quality and innovation. Each model boasts unique features and advanced technologies, allowing users to select the best fit for their specific heating needs. As industry leaders, Burnham products continue to set the standard for performance and efficiency in the boiler market.