Burnham 40A, AL-26A, 53A, 79A manual Removal of Existing Domestic Water Heating System

Page 7

cool to room temperature, or if tank is drained without opening a hot water faucet. A Watts® Model No. N36 is an appropriate vacuum relief valve.

4.Thermal Expansion Tank If water heater is installed in a closed water supply system, such as one having a back-flow preventer in the cold water line, provide thermal expansion control. Contact the water supplier or local plumbing inspector for additional information. An Amtrol Model ST-12 is an appropriate diaphragm style thermal expansion tank for most installations.

F.Removal of Existing Domestic Water Heating System

1.External Tankless Heater - Disconnect from boiler piping and domestic water system.

2.Tankless and Storage Heaters - Disconnect from domestic water system. Heater does not need to be removed from boiler. If left in place, do not plug

inlet and outlet tappings.

G.Water Quality Improper water quality will reduce the expected life of the Alliance™ water heater. Hard water, sediment, high or low water Ph, and high levels of chlorides in the domestic water should be avoided. Sediment and hard water will coat the water heater coil surfaces and reduce the rating of the water heater and may, eventually, cause a failure. High or low Ph and/ or high chloride concentrations will cause the stainless steel water heater components to corrode and eventually fail. A filter is strongly recommended where sediment is present in the water. A water softening system is recommended for areas with hard water.

In areas where water quality is unknown, a water quality test should be performed.

WARNING

Do not operate ALLIANCE™ water heater in areas where water Ph is above 8.0 or below 6.0, and/or with chloride concentrations greater than 80 parts per million (ppm). Burnham's Standard Warranty does not cover problems caused by improper water Ph or excessive levels of chlorides.

7

Image 7
Contents INDIRECT-FIRED Water Heaters For Single Water Heater InstallationsT IC E General Information Table of ContentsAlliance Water Heater Dimension Inches Important Decisions Required Before Installation II. Pre-InstallationDomestic Hot Water Priority Two options are Removal of Existing Domestic Water Heating System Hot Water and Relief Valve Piping III. PipingCold Water Supply Piping Water Boiler Piping with Zone Valves and a Boiler Bypass Page Page Page Page IV. Electrical Operation VI. Service Instructions Problem Cause Solution VII. Trouble ShootingVIII. Repair Parts Urnham Corporation Regional Offices Inspection / Service Schedule

53A, 40A, 79A, AL-26A specifications

The Burnham line of engineering includes several models known for their efficiency, advanced technology, and adaptability to various applications. Notably, the Burnham 40A, 53A, AL-26A, and 79A are among the most respected in the industry, each offering distinct features tailored to meet the needs of residential and commercial users.

The Burnham 40A is a versatile boiler designed for small to medium-sized applications. One of its main features is its efficient heat exchange system, which maximizes the transfer of heat while minimizing energy consumption. This model incorporates advanced burners that provide uniform heating and enhanced fuel efficiency, ensuring lower operational costs for users. Additionally, it is engineered to be compatible with different fuel types including natural gas and propane, providing versatility and flexibility for installations.

The Burnham 53A, on the other hand, emphasizes durability and reliability. This model is built with a robust steel construction, designed to withstand harsh conditions while maintaining a low maintenance profile. The hybrid design allows for a more significant heat output, making it suitable for larger spaces. Moreover, its integrated control system offers precise temperature management, essential for both comfort and energy savings.

In the portfolio, the AL-26A stands out due to its advanced automation technology. This model features smart control mechanisms that facilitate easy monitoring and adjustments. Users can optimize performance through a user-friendly interface, attracting those who value convenience. Furthermore, the AL-26A has enhanced safety features that ensure reliable operation, reducing the risk of malfunctions.

Finally, the Burnham 79A is a powerhouse, specifically engineered for heavy-duty commercial applications. With high-capacity output, it is capable of meeting demanding heating requirements without sacrificing efficiency. This model incorporates sophisticated insulation technologies that reduce heat loss, thus promoting energy conservation. Its design ensures ease of access for maintenance, thereby extending the lifecycle of the boiler.

In conclusion, the Burnham 40A, 53A, AL-26A, and 79A are exemplary models that reflect the brand's commitment to quality and innovation. Each model boasts unique features and advanced technologies, allowing users to select the best fit for their specific heating needs. As industry leaders, Burnham products continue to set the standard for performance and efficiency in the boiler market.