Burnham AL-26A, 53A, 79A, 40A manual Alliance Water Heater Dimension Inches

Page 4

Table 1: Alliance Water Heater Dimension (Inches)

ALL IA NCE

A

B

C

D

E

F

G

H

I

J

K

MODEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AL 26A

40

20-1/4

31-1/2

22-1/2

9-3/4

2

3/4

3/4

3/4

3/4

3/4

 

 

 

 

 

 

 

 

 

 

 

 

AL 40A

55

20-1/4

46-1/2

25-3/4

9-3/4

2

3/4

3/4

3/4

3/4

3/4

 

 

 

 

 

 

 

 

 

 

 

 

AL 53A

70-5/8

20-1/4

62-1/8

28-3/4

9-3/4

2

3/4

3/4

3/4

3/4

3/4

 

 

 

 

 

 

 

 

 

 

 

 

AL 79A

69-3/8

23-3/4

60-7/8

29-1/4

10-1/4

1-5/8

1

3/4

3/4

1

1

 

 

 

 

 

 

 

 

 

 

 

 

AL119A

66

29-1/2

52-3/4

39-1/4

12-3/4

2-1/2

1-1/4

1-1/4

1-1/4

1-1/4

1

 

 

 

 

 

 

 

 

 

 

 

 

Table 2: Alliance Water Heater Capacities

 

TANK

COIL

DRY

WET

COIL HEAT

M AXIMUM

HYDROSTATIC

ALLIANCE

ALLOWABLE

VOLUME

VOLUME

WEIGHT

WEIGHT

TRANSFER

DESIGN

MODEL

WORKING

(GAL)

(GAL)

(LB S)

(LB S)

AREA (SQ. FT.)

PRESSURE (PSI)

 

PRESSURE (PSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AL 26A

26.4

1.0

49

269

6.5

150

300

 

 

 

 

 

 

 

 

AL 40A

39.6

1.2

66

396

8.6

150

300

 

 

 

 

 

 

 

 

AL 53A

52.8

1.4

82

522

9.7

150

300

 

 

 

 

 

 

 

 

AL 79A

79.3

2.2

170

831

15.1

150

300

 

 

 

 

 

 

 

 

AL119A

119.4

2.9

183

1178

24.3

150

300

 

 

 

 

 

 

 

 

Table 3: Alliance Water Heater Performance

 

M AXIM U M FIR ST

CO NT IN UO U S

B O IL ER D OE

M INIM UM B OI LER

P R ES SUR E

M IN UT ES O F

 

HO UR RAT IN G

RAT IN G

MO DE L

H E ATIN G C APA CITY

W ATER F LO W

D RO P TH ROU GH

1 40 F W ATER

G AL/ HR @

G AL /M IN @

N EE DED FOR

TH R OU GH HE ATER

C OI L AT M IN .

AVA IL AB L E AT

 

 

 

 

 

 

 

 

14 0 F

11 5 F

14 0 F

11

5 F

R ATING S (B TU/HR )

C O IL (GA L /M IN )

FL OW (F T. W .C .)

5 GP M D RAW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A L 2 6 A

1 42

1 97

1. 93

2.

84

11 0 ,0 00

8 .0

2 .5

2 .4

 

 

 

 

 

 

 

 

 

 

A L 4 0 A

1 75

2 42

2. 26

3.

38

13 3 ,0 00

11 .4

6 .1

7 .2

 

 

 

 

 

 

 

 

 

 

A L 5 3 A

2 24

3 10

2. 85

4.

29

16 4 ,0 00

10 .9

6 .5

9 .0

 

 

 

 

 

 

 

 

 

 

A L 7 9 A

2 53

3 50

2. 90

4.

51

19 0 ,0 00

10 .6

8 .4

9 .1

 

 

 

 

 

 

 

 

 

 

A L 11 9 A

3 50

4 09

3. 84

4.

83

38 6 ,0 00

15 .4

11 .6

16 .4

 

 

 

 

 

 

 

 

 

 

N O T E S : A l l ra tin g s b a s e d o n 2 0 0 F b o ile r w a te r te m p e ra tu re , 5 0 F d o m e s tic w a te r in le t te m p e ra tu r e , a n d a fu lly re c o ve r e d ta n k (w h e n a p p lic a b le ).

4

Image 4
Contents For Single Water Heater Installations INDIRECT-FIRED Water HeatersT IC E Table of Contents General InformationAlliance Water Heater Dimension Inches II. Pre-Installation Important Decisions Required Before InstallationDomestic Hot Water Priority Two options are Removal of Existing Domestic Water Heating System III. Piping Hot Water and Relief Valve PipingCold Water Supply Piping Water Boiler Piping with Zone Valves and a Boiler Bypass Page Page Page Page IV. Electrical Operation VI. Service Instructions VII. Trouble Shooting Problem Cause SolutionVIII. Repair Parts Urnham Corporation Regional Offices Inspection / Service Schedule

53A, 40A, 79A, AL-26A specifications

The Burnham line of engineering includes several models known for their efficiency, advanced technology, and adaptability to various applications. Notably, the Burnham 40A, 53A, AL-26A, and 79A are among the most respected in the industry, each offering distinct features tailored to meet the needs of residential and commercial users.

The Burnham 40A is a versatile boiler designed for small to medium-sized applications. One of its main features is its efficient heat exchange system, which maximizes the transfer of heat while minimizing energy consumption. This model incorporates advanced burners that provide uniform heating and enhanced fuel efficiency, ensuring lower operational costs for users. Additionally, it is engineered to be compatible with different fuel types including natural gas and propane, providing versatility and flexibility for installations.

The Burnham 53A, on the other hand, emphasizes durability and reliability. This model is built with a robust steel construction, designed to withstand harsh conditions while maintaining a low maintenance profile. The hybrid design allows for a more significant heat output, making it suitable for larger spaces. Moreover, its integrated control system offers precise temperature management, essential for both comfort and energy savings.

In the portfolio, the AL-26A stands out due to its advanced automation technology. This model features smart control mechanisms that facilitate easy monitoring and adjustments. Users can optimize performance through a user-friendly interface, attracting those who value convenience. Furthermore, the AL-26A has enhanced safety features that ensure reliable operation, reducing the risk of malfunctions.

Finally, the Burnham 79A is a powerhouse, specifically engineered for heavy-duty commercial applications. With high-capacity output, it is capable of meeting demanding heating requirements without sacrificing efficiency. This model incorporates sophisticated insulation technologies that reduce heat loss, thus promoting energy conservation. Its design ensures ease of access for maintenance, thereby extending the lifecycle of the boiler.

In conclusion, the Burnham 40A, 53A, AL-26A, and 79A are exemplary models that reflect the brand's commitment to quality and innovation. Each model boasts unique features and advanced technologies, allowing users to select the best fit for their specific heating needs. As industry leaders, Burnham products continue to set the standard for performance and efficiency in the boiler market.