Dayton 5S1792 specifications General Safety Information Theory of Operation Fuels

Page 4

Dayton Operating Instructions and Parts Manual

2E510F, 2E511F, 3E218F, and 3E219F

Dayton® Portable

Oil-Fired Heaters

General Safety Information

Theory of Operation

 

Fuels

 

(Continued)

 

THE FUEL SYSTEM

 

 

 

Use only Kerosene,

 

 

 

 

 

 

 

 

 

 

Heaters used in the vicinity of

The air pump forces air through the

 

 

#1/#2 diesel/fuel

 

 

oil, JET A or JP-8 fuels to avoid risk of

 

tarpaulins, canvas, or similar

air line. The air is then pushed

 

 

 

fire or explosion. Never use gasoline,

 

enclosure materials shall be located

through the burner head nozzle. This

naphtha, paint thinners, alcohol, or

 

a safe distance from such materials.

air causes fuel to lift from the tank. A

other highly flammable fuels.

 

The recommended minimum safe

fine mist of fuel is sprayed into the

Use only kerosene, #1/#2 diesel/fuel oil,

 

distance is 10 feet. It is further

 

combustion chamber.

 

JET A or JP-8 fuels. Heavier fuels such

 

recommended that these enclosure

 

 

THE AIR SYSTEM

 

as No. 2 fuel oil or No. 2 diesel fuel may

 

materials be of a fire retardant

 

 

 

 

 

also be used but will result in:

 

nature. These enclosure materials

The motor turns the fan. The fan

 

 

 

 

 

 

 

shall be securely fastened to

pushes air into and around the

 

• clogged fuel filter and nozzle

 

prevent them from igniting or from

combustion chamber. This air is heated

• the need of nontoxic anti-icer in

 

upsetting the heater due to wind

 

and provides a stream of clean, hot air.

fuel during very cold weather

 

action.

 

 

 

THE IGNITION SYSTEM

 

IMPORTANT: Use a KEROSENE ONLY

Minimum heater clearances from

 

 

 

 

The ignition control assembly provides

container. Be sure storage container is

 

combustibles:

 

 

 

power to the ignitor. This ignites the

clean. Foreign matter such as rust, dirt, or

 

Outlet: 8 Ft.

Sides: 4 Ft.

 

fuel/air mixture in the combustion

water will cause the flame-out control to

 

Top: 4 Ft.

Rear: 4 Ft.

 

chamber.

 

 

shut down heater. Foreign matter may also

Locate heater on a stable and level

 

 

THE FLAME-OUT CONTROL SYSTEM

require you to clean fuel system often.

 

surface while hot or running or a fire

 

This system causes the heater to shut

 

 

 

 

may occur.

 

 

 

 

When moving or storing heater, keep

down if the flame goes out.

 

 

 

 

 

 

 

 

 

 

 

heater in a level position or fuel

 

Combustion Chamber

 

 

 

 

 

spillage may occur.

 

 

Ignitor

Motor

Air Pump

Keep children and animals away

 

 

 

 

Air Intake

 

 

 

 

Fan

Filter

 

from heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

Unplug heater when not in use.

 

 

 

 

 

 

This heater is equipped with thermo-

Clean

 

 

 

 

Cool

 

stat, heater may start anytime.

 

 

 

 

Air In

 

Heated

 

 

 

 

 

Never use heater in living or sleep-

Air Out

 

 

 

 

 

 

 

 

 

 

 

 

ing areas.

 

 

 

 

 

 

 

Never block air inlet (rear) or air

 

 

 

 

 

Air

 

 

 

 

 

Output

 

outlet (front) of heater.

 

 

 

 

 

 

 

 

 

 

 

Filter

Never move, handle, refuel, or

 

 

 

 

 

 

 

service a hot, operating, or plugged-

 

 

 

 

 

 

 

in heater.

 

 

 

 

 

 

 

Never attach duct work to front or

Fuel

Nozzle

Fuel

Air Line

Ignition Control

 

rear of heater.

 

 

 

Tank

 

Filter

To Burner

Assembly

Warning to New York City Residents

For Use Only At Construction Sites in

Air For Fuel

Air For Combus-

Fuel

accordance with applicable NYC codes

System

tion and Heating

 

 

 

 

under NYCFD certificate of approval

 

 

 

#4803, #4899, #4908, #4909, or #4934.

Figure 5 - Cross Section Operational View

 

 

 

 

 

111166-01A

4

Image 4
Contents Description General SpecificationsUnpacking Electrical Specifications Product IdentificationGeneral Safety Information Models 2E510F, 2E511F, 3E218F, and 3E219FGeneral Safety Information Theory of Operation Fuels Ventilation AssemblyOperation Maintenance Upper Shell RemovalFAN AIR OUTPUT, AIR INTAKE, and Lint FiltersPump Pressure Adjustment Fuel FilterReplacement and Proper Routing IgnitorFuel and AIR Line Replacement and Proper Routing NozzleIgnition Control Assembly Pump RotorPreventative Maintenance Schedule Storing TRANSPORTING, or ShippingFor Repair Parts, call Part 2E510F 2E511F Description Number Qty 2E510F and 2E511F Repair Parts List for Models 2E510F and 2E511F 3E218F Repair Parts List for Model 3E218F 3E219F Repair Parts List for Model 3E219F Maintenance Kits AccessoriesWiring Diagram Ignition ControlTroubleshooting Chart Clean photocell lens Not a UPC

5S1792 specifications

The Dayton 5S1792 is a high-performance, compact fan designed primarily for industrial applications, known for its efficiency, durability, and versatility. Built by Dayton, a renowned manufacturer of electric motors and associated products, the 5S1792 model stands out in the market due to its thoughtful engineering and innovative features.

One of the main characteristics of the Dayton 5S1792 is its robust construction. The fan's housing is made from high-quality materials that resist corrosion and protect it against the rigors of demanding environments. This durability not only extends the lifespan of the product but also ensures reliable performance over time, making it ideal for various industrial settings, including factories and warehouses.

The Dayton 5S1792 features a powerful motor that provides consistent airflow, crucial for maintaining optimal conditions in workplaces. With a high airflow capability, the fan effectively circulates air, ensuring that spaces remain cool and comfortable, which is vital for worker productivity and equipment efficiency. The fan is also designed to operate quietly, making it suitable for environments where noise levels are a concern.

In terms of technology, the Dayton 5S1792 is engineered with energy efficiency in mind. It employs advanced motor technologies that not only reduce power consumption but also minimize heat generation. This aspect is particularly beneficial for organizations looking to lower their energy costs while maintaining high-performance standards.

The flexibility of the Dayton 5S1792 is another key feature. It is available in various sizes and configurations, allowing users to select the model that best suits their specific needs. Additionally, the fan can be mounted in multiple orientations, making it adaptable to different installation requirements, whether wall-mounted, ceiling-mounted, or on stands.

Maintenance of the Dayton 5S1792 is straightforward, thanks to its user-friendly design. Accessible components facilitate easier cleaning and servicing, which is essential for prolonging the unit's lifespan and ensuring it operates at peak efficiency.

In summary, the Dayton 5S1792 is a standout choice for those seeking a reliable and efficient fan for industrial use. Its robust construction, powerful motor, energy-efficient design, and versatility make it a trusted option for enhancing airflow in various applications. The consideration of maintenance and ease of use further adds to its appeal, establishing it as a valuable investment for any industrial facility.