Dayton 5S1792 specifications Assembly, Ventilation, Operation

Page 5

Dayton Operating Instructions and Parts Manual

Models 2E510F, 2E511F, 3E218F, and 3E219F

Assembly

IMPORTANT: When installing wheels,

(For Models 3E218F and 3E219F Only)

point extended hub of wheels toward

wheel support frame (See Figure 6).

 

TO START HEATER

1.Follow all ventilation and safety information.

These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.

TOOLS NEEDED

• Medium Phillips Screwdriver

2.Place cap nuts on axle ends. Gently tap with hammer to secure.

3.Place heater on wheel support frame. Make sure air inlet end (rear) of heater is over wheels. Line up holes on fuel tank flange with holes on wheel support frame.

2.Locate heater to provide maximum circulation of the heated air. Follow all location requirements noted in General Safety Information, page 3.

3.Fill fuel tank with Kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels.

3/8" Open or Adjustable Wrench

Hammer

1.Slide axle through wheel support frame. Install wheels on axle.

Front Handle

Rear Handle

Screw

Hot Air

Outlet

Air

FuelInlet

Tank

Flange

Wheel Support

Frame

Nut

Extended

Hub

Axle

Cap Nut

Wheel

Figure 6 - Wheel and Handle Assembly, Models 3E218F and 3E219F Only

4.Place handles on top of fuel tank flange. Insert screws through handles, fuel tank flange, and wheel support frame. Attach nut finger tight after inserting each screw.

5.After inserting all screws, tighten nuts firmly.

Ventilation

Follow the mini- mum fresh, outside

air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.

Provide a fresh air opening of at least three square feet for each 100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.

Example: A 155,000 Btu/Hr heater requires one of the following:

a two-car garage door (16-foot-wide opening) raised 3.5 inches

a single-car garage door (9-foot- wide opening) raised 6.5 inches

two, 30-inch windows raised 11.5 inches

Operation

4.Attach fuel cap.

5.If equipped, turn thermostat knob clockwise to the HIGH position.

6.Plug power cord of heater into three-prong, grounded extension cord. Extension cord must be at least six feet long.

EXTENSION CORD WIRE SIZE

REQUIREMENTS

6 to 10 feet long, use 18 AWG rated cord.

11 to 100 feet long, use 16 AWG rated cord.

101 to 200 feet long, use 14 AWG rated cord.

7.Plug extension cord into standard 120 Volt/60 hertz, three-hole, grounded outlet.

NOTE: Ignitor will preheat for five seconds, then heater will start.

8.If equipped, adjust thermostat knob to the desired setting.

NOTE: If equipped, a cold heater may affect the thermostat setting. Further adjustments may be needed until the heater cycles at the desired setting.

This thermostat is a general-heating control. It is not intended for precise temperature control.

Review and understand the

warnings in the General Safety Information section. They are needed to safely operate this heater. Follow all local codes when using this heater.

TO STOP HEATER

Unplug extension cord from outlet.

TO RESET HEATER

1.Unplug extension cord from outlet and wait 10 seconds (two minutes if heater has been running).

2.Repeat steps under To Start Heater.

®

111166-01A

5

Image 5
Contents Unpacking General SpecificationsDescription Product Identification Electrical SpecificationsModels 2E510F, 2E511F, 3E218F, and 3E219F General Safety InformationGeneral Safety Information Theory of Operation Fuels Operation AssemblyVentilation Upper Shell Removal MaintenanceFAN AIR OUTPUT, AIR INTAKE, and Lint FiltersFuel Filter Pump Pressure AdjustmentIgnitor Replacement and Proper RoutingNozzle Fuel and AIR Line Replacement and Proper RoutingPump Rotor Ignition Control AssemblyStoring TRANSPORTING, or Shipping Preventative Maintenance ScheduleFor Repair Parts, call Part 2E510F 2E511F Description Number Qty 2E510F and 2E511F Repair Parts List for Models 2E510F and 2E511F 3E218F Repair Parts List for Model 3E218F 3E219F Repair Parts List for Model 3E219F Accessories Maintenance KitsIgnition Control Wiring DiagramTroubleshooting Chart Clean photocell lens Not a UPC

5S1792 specifications

The Dayton 5S1792 is a high-performance, compact fan designed primarily for industrial applications, known for its efficiency, durability, and versatility. Built by Dayton, a renowned manufacturer of electric motors and associated products, the 5S1792 model stands out in the market due to its thoughtful engineering and innovative features.

One of the main characteristics of the Dayton 5S1792 is its robust construction. The fan's housing is made from high-quality materials that resist corrosion and protect it against the rigors of demanding environments. This durability not only extends the lifespan of the product but also ensures reliable performance over time, making it ideal for various industrial settings, including factories and warehouses.

The Dayton 5S1792 features a powerful motor that provides consistent airflow, crucial for maintaining optimal conditions in workplaces. With a high airflow capability, the fan effectively circulates air, ensuring that spaces remain cool and comfortable, which is vital for worker productivity and equipment efficiency. The fan is also designed to operate quietly, making it suitable for environments where noise levels are a concern.

In terms of technology, the Dayton 5S1792 is engineered with energy efficiency in mind. It employs advanced motor technologies that not only reduce power consumption but also minimize heat generation. This aspect is particularly beneficial for organizations looking to lower their energy costs while maintaining high-performance standards.

The flexibility of the Dayton 5S1792 is another key feature. It is available in various sizes and configurations, allowing users to select the model that best suits their specific needs. Additionally, the fan can be mounted in multiple orientations, making it adaptable to different installation requirements, whether wall-mounted, ceiling-mounted, or on stands.

Maintenance of the Dayton 5S1792 is straightforward, thanks to its user-friendly design. Accessible components facilitate easier cleaning and servicing, which is essential for prolonging the unit's lifespan and ensuring it operates at peak efficiency.

In summary, the Dayton 5S1792 is a standout choice for those seeking a reliable and efficient fan for industrial use. Its robust construction, powerful motor, energy-efficient design, and versatility make it a trusted option for enhancing airflow in various applications. The consideration of maintenance and ease of use further adds to its appeal, establishing it as a valuable investment for any industrial facility.