STORING TRANSPORTING, OR SHIPPING

NOTE: If shipping, transport companies require fuel tanks to be empty.

1. Drain fuel tank.

NOTE: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed.

2.Replace drain plug if provided.

3.If any debris is noted in old fuel, add 1 or 2 quarts of clean Kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use.

4.Replace fuel cap or drain plug. Properly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.

5.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store Kerosene over summer months for use during next heating season. Using old fuel could damage heater.

Preventative Maintenance Schedule

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

Item

How Often

How To

Fuel tank

Flush every 150-200 hours of operation or as needed

See Storing, Transporting, or Shipping,

 

 

above

Air output and

Replace every 500 hours of operation or once a year

See Air Output, Air Intake, and Lint

lint filters

 

Filters, page 6

Air intake filter

Wash and dry with soap and water every 500 hours of

See Air Output, Air Intake, and Lint

 

operation or as needed

Filters, page 6

Fuel filter

Clean twice a heating season or as needed

See Fuel Filter, page 7

Fan blades

Clean every season or as needed

See Fan, page 6

Motor

Not required/permanently lubricated

 

®

111166-01A

11

Image 11
Contents Unpacking General SpecificationsDescription Product Identification Electrical SpecificationsModels 2E510F, 2E511F, 3E218F, and 3E219F General Safety InformationGeneral Safety Information Theory of Operation Fuels Operation AssemblyVentilation AIR OUTPUT, AIR INTAKE, and Lint Filters MaintenanceUpper Shell Removal FANFuel Filter Pump Pressure AdjustmentIgnitor Replacement and Proper RoutingNozzle Fuel and AIR Line Replacement and Proper RoutingPump Rotor Ignition Control AssemblyStoring TRANSPORTING, or Shipping Preventative Maintenance ScheduleFor Repair Parts, call Part 2E510F 2E511F Description Number Qty 2E510F and 2E511F Repair Parts List for Models 2E510F and 2E511F 3E218F Repair Parts List for Model 3E218F 3E219F Repair Parts List for Model 3E219F Accessories Maintenance KitsIgnition Control Wiring DiagramTroubleshooting Chart Clean photocell lens Not a UPC

5S1792 specifications

The Dayton 5S1792 is a high-performance, compact fan designed primarily for industrial applications, known for its efficiency, durability, and versatility. Built by Dayton, a renowned manufacturer of electric motors and associated products, the 5S1792 model stands out in the market due to its thoughtful engineering and innovative features.

One of the main characteristics of the Dayton 5S1792 is its robust construction. The fan's housing is made from high-quality materials that resist corrosion and protect it against the rigors of demanding environments. This durability not only extends the lifespan of the product but also ensures reliable performance over time, making it ideal for various industrial settings, including factories and warehouses.

The Dayton 5S1792 features a powerful motor that provides consistent airflow, crucial for maintaining optimal conditions in workplaces. With a high airflow capability, the fan effectively circulates air, ensuring that spaces remain cool and comfortable, which is vital for worker productivity and equipment efficiency. The fan is also designed to operate quietly, making it suitable for environments where noise levels are a concern.

In terms of technology, the Dayton 5S1792 is engineered with energy efficiency in mind. It employs advanced motor technologies that not only reduce power consumption but also minimize heat generation. This aspect is particularly beneficial for organizations looking to lower their energy costs while maintaining high-performance standards.

The flexibility of the Dayton 5S1792 is another key feature. It is available in various sizes and configurations, allowing users to select the model that best suits their specific needs. Additionally, the fan can be mounted in multiple orientations, making it adaptable to different installation requirements, whether wall-mounted, ceiling-mounted, or on stands.

Maintenance of the Dayton 5S1792 is straightforward, thanks to its user-friendly design. Accessible components facilitate easier cleaning and servicing, which is essential for prolonging the unit's lifespan and ensuring it operates at peak efficiency.

In summary, the Dayton 5S1792 is a standout choice for those seeking a reliable and efficient fan for industrial use. Its robust construction, powerful motor, energy-efficient design, and versatility make it a trusted option for enhancing airflow in various applications. The consideration of maintenance and ease of use further adds to its appeal, establishing it as a valuable investment for any industrial facility.