Desa VYM27NRPR installation manual Troubleshooting, Observed Problem Possible Cause

Page 18

18

TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel.

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP gas)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is re- moved

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 17) or replace ODS/ pilot assembly

7.Replace gas control

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Equipment shutoff valve not fully open

4.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/pilot

5.Thermocouple connection loose at con- trol valve

6.Thermocouple damaged

7.Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Fully open equipment shutoff valve

4.A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 17) or replace ODS/ pilot assembly

5.Hand tighten until snug, then tighten 1/4 turn more

6.Replace pilot assembly

7.Replace control valve

For..com

110398-01A

Image 18
Contents VYM27NR/PR FVFM27NR/PR OWNER’S Operation and Installation ManualFLAME-MAX What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product IdentificationLocal Codes Product FeaturesRemote Control Accessories UnpackingUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation and Clearances Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Connecting to GAS Supply Attaching Base Assembly to Fireplace FloorPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Checking Gas Joints for Natural GasFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS to ApplianceOptional Remote Operation Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Ghrcta Series OperationBurner Primary AIR Holes Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at TopService Hints Wiring DiagramSpecifications Technical ServiceIllustrated Parts Breakdown VYM27NR, VYM27PR FVFM27NR, FVFM27PRParts List VYM27NR VYM27PR FVFM27NR FVFM27PRWALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT GhrcWALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT GCKOwners Registration Form Tape 110398-01A Warranty Information

VYM27NRPR specifications

Desa VYM27NRPR is a highly advanced imaging device designed for a multitude of applications, from medical diagnostics to industrial inspections. This remarkable equipment integrates cutting-edge technologies to provide exceptional image quality and versatility.

One of the primary features of the VYM27NRPR is its high-resolution imaging capability. With an advanced sensor that supports multiple resolutions, users can capture stunning images with clarity, revealing intricate details that are crucial for accurate assessments. The device supports a wide range of imaging modes, including grayscale, color, and infrared, allowing users to choose the most suitable option for their specific needs.

Incorporating state-of-the-art image processing technologies, the VYM27NRPR utilizes sophisticated algorithms to enhance the quality of captured images. Features such as noise reduction, contrast enhancement, and edge detection ensure that users receive optimized images, which are vital in fields like medical diagnostics where precise evaluation is essential.

Moreover, the VYM27NRPR comes equipped with advanced connectivity options. Its compatibility with various interfaces, including USB, HDMI, and Wi-Fi, allows for seamless integration with other devices and systems. This connectivity is crucial for data sharing, enabling users to quickly transfer images and collaborate with other professionals in real-time.

The device is designed with user experience in mind. Its intuitive interface offers easy navigation through various settings and modes, ensuring that users can operate it effortlessly. Additionally, the VYM27NRPR features customizable settings, allowing professionals to tailor the device according to their preferences and specific workflows.

Durability is another hallmark of the VYM27NRPR. Built with robust materials, the device is designed to withstand harsh environments, making it suitable for fieldwork in diverse conditions. Furthermore, it has a lightweight design, enabling portability without compromising on performance.

In summary, Desa VYM27NRPR stands out for its high-resolution imaging, advanced processing capabilities, seamless connectivity, user-friendly interface, and durability. This comprehensive suite of features makes it an invaluable tool for professionals across various sectors, revolutionizing how images are captured, processed, and analyzed. As technology continues to evolve, devices like the VYM27NRPR will play a pivotal role in enhancing the accuracy and efficiency of imaging tasks, setting new standards in the industry.