Desa VYM27NRPR installation manual Parts List, VYM27NR VYM27PR FVFM27NR FVFM27PR

Page 23

PARTS LIST

VYM27NR, VYM27PR, FVFM27NR, FVFM27PR

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the

 

 

instructions listed under Replacement Parts on page 21 of this manual.

23

VYM27NR

VYM27PR

FVFM27NR

FVFM27PR

 

PART NUMBER

 

 

KEY

VYM27NR

VYM27PR

 

 

NO.

FVFM27NR

FVFM27PR

DESCRIPTION

QTY.

 

 

 

 

 

1a

104676-01

104676-01

1 Piece Log Set

 

1b

110397-06

110397-06

5 Piece Log Set

1

1-1

110321-01

110321-01

Front Log (#1)

1

1-2

110321-02

110321-02

Rear Log (#2)

1

1-3

110321-05

110321-05

Center Insert Log (#3)

1

1-4

110321-03

110321-03

Top Left Log (#4)

1

1-5

110321-04

110321-04

Top Right Log (#5)

1

2

103779-01

103778-01

ODS Pilot

1

3

098249-01

098249-01

ODS Nut

2

4

104592-01

104592-02

Burner Outlet Tube

1

5

098264-02

098264-02

Male Connector

1

6

102843-01

102843-01

Burner Clip

1

7

099056-16

099056-17

Burner Orifice Injector

1

8

104591-01

104591-01

Burner

1

9

100609-01

099387-13

Pilot Tube (Regulator to Pilot)

1

10

103781-01

103781-02

Gas Control Valve

1

11

104611-01

104611-01

Lower Bracket

1

12

098304-01

098304-01

Screw, #8 x .38

7

13

104590-01CK

104590-01CK

Painted Base Assy

1

14

098271-06

098271-06

Ignitor Cable

1

15

102445-01

102445-01

Piezo Ignitor

1

16

103587-02CK

103587-02CK

Plate, Switch

1

17

103784-02

103784-02

Flame Adjustment Knob

1

18

103784-01

103784-01

Off-Pilot-On Knob

1

19

M12461-26

M12461-26

Screw, Hex Slt Wsr 10-32 x .38

4

20

103284-02

103284-02

Wiring Harness

1

21

099998-01

099998-01

Switch

1

22

099918-02

___

Pilot Regulator

1

___

23

099387-15

Pilot Tube (Valve to Regulator)

1

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

100563-01

100563-01

Warning Plate

1

 

103877-01

103877-01

Lighting Instructions Plate

1

 

100565-01

100565-01

Warning Plate Fastener

1

 

100639-01

100693-01

Caution Decal

1

 

101137-02

101137-02

Hardware Kit

1

 

GA6060

GA6060

Lava Rock

2

 

 

 

 

 

For morevisit www..com

110398-01A

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFLAME-MAX VYM27NR/PR FVFM27NR/PRSafety Information Table of ContentsProduct Identification Product IdentificationUnpacking Product FeaturesRemote Control Accessories Local CodesConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Minimum Fireplace Clearance to Combustible Materials InstallationInstallation and Clearances Check GAS TypeMinimum Noncombustible Material Clearances If Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When using a HoodMantel Clearances Floor ClearancesInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Attaching Base Assembly to Fireplace Floor Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Checking Gas Joints for Natural Gas Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Ghrcta Series Operation Inspecting BurnersPilot Flame Pattern Burner Flame PatternMain Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Top Gas leak. See Warning statement atTechnical Service Wiring DiagramSpecifications Service HintsVYM27NR, VYM27PR FVFM27NR, FVFM27PR Illustrated Parts BreakdownVYM27NR VYM27PR FVFM27NR FVFM27PR Parts ListCleaning KIT GCK Receiver and HAND-HELD Remote Control KIT GhrcWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Owners Registration Form Tape 110398-01A Warranty Information

VYM27NRPR specifications

Desa VYM27NRPR is a highly advanced imaging device designed for a multitude of applications, from medical diagnostics to industrial inspections. This remarkable equipment integrates cutting-edge technologies to provide exceptional image quality and versatility.

One of the primary features of the VYM27NRPR is its high-resolution imaging capability. With an advanced sensor that supports multiple resolutions, users can capture stunning images with clarity, revealing intricate details that are crucial for accurate assessments. The device supports a wide range of imaging modes, including grayscale, color, and infrared, allowing users to choose the most suitable option for their specific needs.

Incorporating state-of-the-art image processing technologies, the VYM27NRPR utilizes sophisticated algorithms to enhance the quality of captured images. Features such as noise reduction, contrast enhancement, and edge detection ensure that users receive optimized images, which are vital in fields like medical diagnostics where precise evaluation is essential.

Moreover, the VYM27NRPR comes equipped with advanced connectivity options. Its compatibility with various interfaces, including USB, HDMI, and Wi-Fi, allows for seamless integration with other devices and systems. This connectivity is crucial for data sharing, enabling users to quickly transfer images and collaborate with other professionals in real-time.

The device is designed with user experience in mind. Its intuitive interface offers easy navigation through various settings and modes, ensuring that users can operate it effortlessly. Additionally, the VYM27NRPR features customizable settings, allowing professionals to tailor the device according to their preferences and specific workflows.

Durability is another hallmark of the VYM27NRPR. Built with robust materials, the device is designed to withstand harsh environments, making it suitable for fieldwork in diverse conditions. Furthermore, it has a lightweight design, enabling portability without compromising on performance.

In summary, Desa VYM27NRPR stands out for its high-resolution imaging, advanced processing capabilities, seamless connectivity, user-friendly interface, and durability. This comprehensive suite of features makes it an invaluable tool for professionals across various sectors, revolutionizing how images are captured, processed, and analyzed. As technology continues to evolve, devices like the VYM27NRPR will play a pivotal role in enhancing the accuracy and efficiency of imaging tasks, setting new standards in the industry.