Desa VYM27NRPR installation manual Minimum Noncombustible Material Clearances, If Using Mantel

Page 8

8

INSTALLATION

Installation and Clearances (Cont.)

INSTALLATION

Continued

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 4).

Note: When installing your gas logs into a manufactured fire- box, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for Combustible to Wall

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory. Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9, for minimum clearances.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Noncombustible material OK.

Between 8" and 12"

Install fireplace hood accessory

 

(GA6050, GA6052 or GA6053, see

 

Accessories, page 24).

Less than 8"

Noncombustible material must be

 

extended to at least 8". See Be-

 

tween 8" and 12", above. If you

 

cannot extend material, you must

 

operate heater with flue damper

 

open.

 

 

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fire- place opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Heat Resistant

Material

(A)

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above both fireplace openings. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory. See Figure 5 at right for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

For..com

110398-01A

Image 8
Contents OWNER’S Operation and Installation Manual FLAME-MAXVYM27NR/PR FVFM27NR/PR What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product IdentificationProduct Features Remote Control AccessoriesLocal Codes UnpackingProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation and ClearancesCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Connecting to GAS Supply Attaching Base Assembly to Fireplace FloorChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing Logs Checking Gas Joints for Natural GasLighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Inspecting Burners Pilot Flame PatternBurner Flame Pattern Ghrcta Series OperationCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleBurner Primary AIR Holes Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at TopWiring Diagram SpecificationsService Hints Technical ServiceIllustrated Parts Breakdown VYM27NR, VYM27PR FVFM27NR, FVFM27PRParts List VYM27NR VYM27PR FVFM27NR FVFM27PRReceiver and HAND-HELD Remote Control KIT Ghrc WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKOwners Registration Form Tape 110398-01A Warranty Information

VYM27NRPR specifications

Desa VYM27NRPR is a highly advanced imaging device designed for a multitude of applications, from medical diagnostics to industrial inspections. This remarkable equipment integrates cutting-edge technologies to provide exceptional image quality and versatility.

One of the primary features of the VYM27NRPR is its high-resolution imaging capability. With an advanced sensor that supports multiple resolutions, users can capture stunning images with clarity, revealing intricate details that are crucial for accurate assessments. The device supports a wide range of imaging modes, including grayscale, color, and infrared, allowing users to choose the most suitable option for their specific needs.

Incorporating state-of-the-art image processing technologies, the VYM27NRPR utilizes sophisticated algorithms to enhance the quality of captured images. Features such as noise reduction, contrast enhancement, and edge detection ensure that users receive optimized images, which are vital in fields like medical diagnostics where precise evaluation is essential.

Moreover, the VYM27NRPR comes equipped with advanced connectivity options. Its compatibility with various interfaces, including USB, HDMI, and Wi-Fi, allows for seamless integration with other devices and systems. This connectivity is crucial for data sharing, enabling users to quickly transfer images and collaborate with other professionals in real-time.

The device is designed with user experience in mind. Its intuitive interface offers easy navigation through various settings and modes, ensuring that users can operate it effortlessly. Additionally, the VYM27NRPR features customizable settings, allowing professionals to tailor the device according to their preferences and specific workflows.

Durability is another hallmark of the VYM27NRPR. Built with robust materials, the device is designed to withstand harsh environments, making it suitable for fieldwork in diverse conditions. Furthermore, it has a lightweight design, enabling portability without compromising on performance.

In summary, Desa VYM27NRPR stands out for its high-resolution imaging, advanced processing capabilities, seamless connectivity, user-friendly interface, and durability. This comprehensive suite of features makes it an invaluable tool for professionals across various sectors, revolutionizing how images are captured, processed, and analyzed. As technology continues to evolve, devices like the VYM27NRPR will play a pivotal role in enhancing the accuracy and efficiency of imaging tasks, setting new standards in the industry.