Desa HCA-24-RFP, HCA-18-RFN, HCA-18-RFP, HCA-24-RFN Specifications, Wiring Diagram

Page 15

SPECIFICATIONS

 

HCA-24-RFN

HCA-24-RFP

HCA-18-RFN

HCA-18-RFP

 

HCM-24-RFN

HCM-24-RFP

HCM-18-RFN

HCM-18-RFP

 

HKE-24-RFN

HKE-24-RFP

HKE-18-RFN

HKE-18-RFP

Btu (Variable)

45,000/67,000

43,000/65,000

41,000/56,000

42,000/51,000

Type Gas

Natural Gas Only

Propane/LP Only

Natural Gas Only

Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

3.5" - 1.6"W.C.

10" - 6.3"W.C.

3.5" - 1.6"W.C.

10" - 6.3"W.C.

Inlet Gas Pressure (in. of water)

 

 

 

Maximum

10.5" W.C.

13" W.C.

10.5" W.C.

13" W.C.

Minimum*

5.0" W.C.

11" W.C.

5.0" W.C.

11" W.C.

Valve Operation

RF Millivolt

RF Millivolt

RF Millivolt

RF Millivolt

Orifice Size

#21

#42

#28

#45

* For purpose of input adjustment

WIRING DIAGRAM

REMOTE CONTROL (MILLIVOLT)

Outlet

Inlet

Piezo

Pressure

Pressure

 

Tap

Tap

 

 

 

Pilot Tube

Pilot

Burner

Assembly

Local and

Gas Control

Remote Switch

Knob

POWER SUPPLY. PROVIDE

DISCONNECT MEANS AND

OVERLOAD PROTECTION AS

REQUIRED.

 

Pilot

Thermopile

Leadwires

Adjustment

 

Screw

 

Figure 16 - Millivolt System Wiring Diagram

115481-01A

www.desatech.com

15

Image 15
Contents HCA-24-RFP HCM-24-RFP What to do if YOU Smell GASTable of Contents Safety Information Provide adequate clearances around air openings Local CodesProduct Identification High traffic areas Windy or drafty areasGeneral Information InstallationFlue Opening Specifications UnpackingPlacement of Appliance Venting Specifications forInstallation Installing Damper ClampTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsNatural From Gas Meter 5 W.C.** to 10.5 W.C. Pressure Propane/LPLava rock to be used in , Placement of Floor MediaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Correct all leaks at onceOperating Appliance Floor Media Kits InstalledLighting Instructions For Your Safety Read Before LightingUsing Transmitter Remote Operating HeaterShut Off Main Burner Without Remote Shut Off Main Burner Using RemoteInspecting Burners To Turn OFF GAS To ApplianceCleaning Maintenance Technical ServiceReplacement Parts Troubleshooting Observed Problem Possible Cause RemedyNo. of Blinks Service Action Out Problem Or blowing high causingWiring Diagram SpecificationsIllustrated Parts Breakdown Parts List Damper Clamp GA6080 AccessoriesEquipment Shutoff Valve GA5010 Fireplace Hood115481-01A Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Firebox