TROUBLESHOOTING

Continued

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Pilot burning, no gas to burner, valve knob "ON", wall switch "ON"

1.Wall switch or wires defective

2.Thermopile may not be generating sufficient mil- livoltage.

3.Plugged burner orifice

1.Check wall switch and wires for proper connections. Jump- er wire across terminals at wall switch. If burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve. If burner comes on, wires are faulty or connections are bad

2.Check thermopile with mil- livolt meter. Take reading at thermopile terminals of gas valve. It should read 325 mil- livolts minimum with optional wall switch "OFF". Replace faulty thermopile if reading is below specified minimum.

3.Check burner orifice for stop- page and remove

Frequent pilot/burner outage

1. Pilot flame may be too low

problem

or blowing (high) causing

 

the pilot/valve safety to drop

 

out

1.Clean and/or adjust pilot flame for maximum flame impinge- ment on thermocouple (see Figure 13, page 11)

14

www.desatech.com

115481-01A

Image 14
Contents What to do if YOU Smell GAS HCA-24-RFP HCM-24-RFPTable of Contents Safety Information High traffic areas Windy or drafty areas Local CodesProduct Identification Provide adequate clearances around air openingsUnpacking InstallationFlue Opening Specifications General InformationInstalling Damper Clamp Venting Specifications forInstallation Placement of AppliancePropane/LP Checking GAS ConnectionsNatural From Gas Meter 5 W.C.** to 10.5 W.C. Pressure Test Pressures In Excess Of 1/2 Psig 3.5 kPaCorrect all leaks at once Placement of Floor MediaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Lava rock to be used in ,Floor Media Kits Installed Operating ApplianceOperating Heater For Your Safety Read Before LightingUsing Transmitter Remote Lighting InstructionsTo Turn OFF GAS To Appliance Shut Off Main Burner Using RemoteInspecting Burners Shut Off Main Burner Without RemoteReplacement Parts Cleaning MaintenanceTechnical Service No. of Blinks Service Action TroubleshootingObserved Problem Possible Cause Remedy Problem Or blowing high causing OutSpecifications Wiring DiagramIllustrated Parts Breakdown Parts List Fireplace Hood AccessoriesEquipment Shutoff Valve GA5010 Damper Clamp GA6080115481-01A Limited Warranty VENT-FREE Firebox Warranty InformationKeep this Warranty