Desa HCA-18-RFN Placement of Floor Media, Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa

Page 8

INSTALLATION

Continued

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 5).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/ LP (see Figure 6 or 7). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

Open

Shutoff

 

Valve

 

Closed

Figure 5 - Equipment Shutoff Valve

Equipment

Shutoff Valve

Gas Meter

Control Valve

Location

Figure 7 - Checking Gas Joints

(Natural Gas Only)

Gas Pressure Check The appliance regulator controls the burner pres- sure which should be checked at the pressure test point (1/8" NPT plugged tap) located near the on the control valve identified OUT for the manifold side and IN for inlet pressure. Make sure operating pressures are within the limits shown in Specifica- tions, page 15. The pressure should be checked with the unit burning and set to High. Replace test point plug or tighten test screw after pressure measurement ensuring no gas leaks.

PLACEMENT OF FLOOR MEDIA

WARNING: Do not add ex- tra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Use only the

Propane/LP Supply Tank

Equipment

Shutoff Valve

Control Valve

Location

material included in the kits.

WARNING: Do not place lava rock,embersorfiberlogpieceson logs or burners. This may cause sooting.Placefloormediamaterial only on the fireplace floor.

1.

Place lava rock around base of unit making sure

 

the burner ports and valve access are not blocked

 

(see Figure 8, page 9). Retain a small amount of

Figure 6 - Checking Gas Joints

(Propane/LP Gas Only)

 

lava rock to be used in step 4, page 9.

2.

Place ember material around front and sides

 

of unit close to (but NOT on) the burner (see

 

Figure 9, page 9). Embers will "glow" when

 

heated to enhance the realistic look of your

log set.

8

www.desatech.com

115481-01A

Image 8
Contents What to do if YOU Smell GAS HCA-24-RFP HCM-24-RFPTable of Contents Safety Information Local Codes Product IdentificationHigh traffic areas Windy or drafty areas Provide adequate clearances around air openingsInstallation Flue Opening SpecificationsUnpacking General InformationVenting Specifications for InstallationInstalling Damper Clamp Placement of ApplianceChecking GAS Connections Natural From Gas Meter 5 W.C.** to 10.5 W.C. PressurePropane/LP Test Pressures In Excess Of 1/2 Psig 3.5 kPaPlacement of Floor Media Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaCorrect all leaks at once Lava rock to be used in ,Floor Media Kits Installed Operating ApplianceFor Your Safety Read Before Lighting Using Transmitter RemoteOperating Heater Lighting InstructionsShut Off Main Burner Using Remote Inspecting BurnersTo Turn OFF GAS To Appliance Shut Off Main Burner Without RemoteReplacement Parts Cleaning MaintenanceTechnical Service No. of Blinks Service Action TroubleshootingObserved Problem Possible Cause Remedy Problem Or blowing high causing OutSpecifications Wiring DiagramIllustrated Parts Breakdown Parts List Accessories Equipment Shutoff Valve GA5010Fireplace Hood Damper Clamp GA6080115481-01A Limited Warranty VENT-FREE Firebox Warranty InformationKeep this Warranty