Desa HCA-18-RFP, HCA-18-RFN Unpacking, General Information, Installation, Check GAS Type

Page 5

UNPACKING

CAUTION: Do not remove the data plates from the grate as- sembly. The data plates contain important warranty and safety information.

1.Remove log set assembly from carton.

2.Remove all protective packaging applied to log set for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought appliance.

GENERAL INFORMATION

These vented decorative gas log sets incorporate uni-body constructed ceramic fiber logs and ember bed burner which glow realistically when the ap- pliance is in operation.

These units are remote controlled-decorative rated and are equipped with millivolt gas valves. The remote control allows for flame height adjustment, timer and on/off control.

A spark ignition system (piezo) allows the gas pilot to be lit without the use of matches or bat- teries and permits operation of the heater during a power outage.

These log sets come with a Floor Media Kit in- cluded. This kit is used to blend the floor and the log set together for a more natural look.

CAUTION:Thisheatercreates warmaircurrents.Thesecurrents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operatingheaterwhereimpurities (such as, but not limited to, to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

WARNING: Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible material.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not instal in fireplace. Call dealer where you bought the appliance for proper type of appliance.

INSTALLATION

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creo- sote will ignite if highly heated. A dirtychimneyfluemaycreateand distribute soot within the house. Inspectchimneyfluefordamage. If damaged, repair flue damper before operating appliance.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. The fireplace chimney must have a permanent vent opening to outside of not less than 29 square inches or as determined from manufacturer's installation instructions.

LOG SIZING REQUIREMENTS

 

MINIMUM FIREBOX SIZE

LOG

 

 

FRONT

REAR

SIZE

HEIGHT

DEPTH

WIDTH

WIDTH

18"

14"

16"

30"

20"

24"

18"

18"

34"

24"

 

 

 

 

 

115481-01A

www.desatech.com

5

Image 5
Contents HCA-24-RFP HCM-24-RFP What to do if YOU Smell GASTable of Contents Safety Information Product Identification Local CodesHigh traffic areas Windy or drafty areas Provide adequate clearances around air openingsFlue Opening Specifications InstallationUnpacking General InformationInstallation Venting Specifications forInstalling Damper Clamp Placement of ApplianceNatural From Gas Meter 5 W.C.** to 10.5 W.C. Pressure Checking GAS ConnectionsPropane/LP Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Placement of Floor MediaCorrect all leaks at once Lava rock to be used in ,Operating Appliance Floor Media Kits InstalledUsing Transmitter Remote For Your Safety Read Before LightingOperating Heater Lighting InstructionsInspecting Burners Shut Off Main Burner Using RemoteTo Turn OFF GAS To Appliance Shut Off Main Burner Without RemoteReplacement Parts Cleaning MaintenanceTechnical Service No. of Blinks Service Action TroubleshootingObserved Problem Possible Cause Remedy Out Problem Or blowing high causingWiring Diagram SpecificationsIllustrated Parts Breakdown Parts List Equipment Shutoff Valve GA5010 AccessoriesFireplace Hood Damper Clamp GA6080115481-01A Limited Warranty VENT-FREE Firebox Warranty InformationKeep this Warranty