Desa CGP10TA, CGP10TLA Connecting to GAS Supply, External Regulator With Vent Pointing Down

Page 9

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator be- tween the heater and propane/LP supply.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

12.Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include an equipment shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Propane/LP

Supply

Tank External

Regulator

Vent

Pointing

Down

Figure 12 - External Regulator With Vent Pointing Down

3/8" NPT Pipe Nipple

Ground Joint Union

Equipment Shutoff

Valve *

From External Regulator (11" W.C. to 14" W.C. Pressure)

3" Minimum

Figure 13 - Gas Connection

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas pip- ing and/or fittings.

Pressure

Regulator

Heater

Cabinet

Tee Joint

 

 

 

 

Reducer

 

 

 

Test

Bushing to

 

 

Gauge

1/8" NPT

 

 

 

 

 

 

Connection *

1/8" NPT

 

 

 

 

 

 

 

Plug Tap

 

 

 

 

 

 

 

 

Tee

 

 

 

 

 

 

 

 

 

 

 

 

Joint

 

 

 

 

 

Pipe

 

Sediment Trap

 

Nipple

 

 

 

 

 

Cap

 

 

 

 

 

 

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory, page 13.

Continued

104268

9

Image 9
Contents What to do if YOU Smell GAS CGP10TA CGP10TLAVENT-FREE PROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpacesAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installing Bottom Mounting Screw Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Removing Front Panel Of HeaterExternal Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Burner Service Publications Hints Cleaning and MaintenanceAccessory Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts Central Parts Under WarrantyParts not Under Warranty CGP10TA CGP10TLA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListWarranty Information

CGP10TLA, CGP10TA specifications

Desa CGP10TA and CGP10TLA are advanced generator models known for their reliability and performance in various applications. These generators are designed to cater to both residential and light commercial needs, providing an efficient power solution anytime and anywhere.

One of the most notable features of the CGP10TA and CGP10TLA is their robust engine performance. These generators are powered by a high-quality, air-cooled four-stroke engine that ensures durability and long operational life. Their engines are optimized for fuel efficiency, enabling users to minimize operational costs while maximizing usability.

The CGP10TA and CGP10TLA models come equipped with automatic voltage regulation (AVR) technology. This feature guarantees stable voltage output, which is essential for sensitive electronic devices. By maintaining consistent voltage levels, the generators protect appliances from potential damage caused by power surges or fluctuations, thereby enhancing user confidence.

Safety is another priority in the design of these generators. Both models include essential safety features such as low-oil shutdown, which automatically turns off the engine when oil levels drop below a certain threshold. This safeguard helps prevent engine damage and prolongs the generator's lifespan, making it a wise choice for conscientious users.

Portability is a standout characteristic of the Desa CGP10TA and CGP10TLA generators. Each unit is designed with a lightweight frame, convenient carrying handles, and rubber wheels, allowing for easy transportation to various locations. Whether you need backup power during a storm, for camping, or to support outdoor events, these generators are versatile and user-friendly.

Moreover, these generators are engineered for quiet operation. Their noise-reduction technologies ensure a peaceful environment, making them suitable for residential areas and outdoor gatherings where excessive noise could be disruptive. Users can enjoy reliable power without the worry of disturbing neighbors or losing the tranquility of nature.

In terms of connectivity, both models include multiple AC and DC outlets, making it easy to power various devices simultaneously. Whether it's lights, power tools, or electronics, these generators can handle the load with ease, providing versatility for any power needs.

In conclusion, the Desa CGP10TA and CGP10TLA generators represent a blend of performance, safety, and convenience. With their advanced engine technology, automatic voltage regulation, safety features, portability, and quiet operation, they stand out as excellent choices for anyone in need of reliable, efficient, and user-friendly power solutions.