Desa CVDA18R To Turn OFF GAS to Appliance, Curing Logs, Optional Remote Operation

Page 11

OPERATING APPLIANCE

To Turn Off Gas To Appliance

Curing Logs

Optional Remote Operation

GWMS2 Wall Mounted Switch

11

OPERATING APPLIANCE

Continued

TO TURN OFF GAS TO APPLIANCE

Shutting Off Appliance

Slightly push in and turn control knob clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burner and keep the pilot lit by doing one of the following:

1.Slightly push in and turn control knob clockwise to the PILOT position.

2.If Using Optional Hand-Held Remote or Wall Switch:

Set switch to OFF position.

CURING LOGS

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and com- pounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

Ignite a 2" flame and maintain it for 1 hour.

Burn the logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.

OPTIONAL REMOTE OPERATION

Note: All remote control accessories must be purchased sepa- rately. Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand- held remote control unit. See Lighting Instructions, page 10.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Slide the selector switch to the REMOTE position. Note: The burner may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the RE- MOTE position when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

GHRC Operation:

2.Press the ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.

GWMS2 WALL MOUNTED SWITCH

(OPTIONAL)

This wall switch works just like the conventional light switch. Flip the switch up for on and down for off.

Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the log set being inadvertently turned on without the proper precautions being taken. See installation instructions on page 8 of this manual.

For more information, visit www.desatech.com

901273-01D

Image 11
Contents What to do if YOU Smell GAS Owners Operation and Installation ManualSafety Information Table of ContentsProduct Identification Product FeatureRemote Ready Safety VALVE/PILOT Local CodesCheck GAS Type InstallationFlue Opening Specifications Venting Specifications for InstallationInstallation Items Needed Installing Damper ClampConnecting to GAS Supply Checking GAS Connections Hearth PAN InstallationPressure Testing Gas Supply Piping System Burner Inlet Fitting Adjusting Regulator Pressure For Propane/LP ConversionPropane/LP Gas Conversion GWMS2 Testing Burner for LeaksRemote Control Options Adding PAN MaterialInstalling Grate Pan Material Not Shown Installing Grate and LogsLighting Instructions For Your Safety Read Before LightingIf Using Optional Hand-Held Remote or Wall Switch Operating ApplianceOptional Remote Operation GWMS2 Wall Mounted Switch OptionalTo Turn OFF GAS to Appliance Curing LogsInspecting Burners Cleaning MaintenanceReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingFor more Visit www Com Gas leak. See Warning statement at TopModels VVSA18R, VVSA24R, VVDA18R VVDA24R, and VVDA30R Illustrated Parts BreakdownParts Available not Shown Parts ListKingston Split Oak Logs Hanover Round Oak Logs Parts List Models FVSA18R, FVSA24R, FVDA18R FVDA24R, and FVDA30R Illustrated Parts BREAK- DownParts Available not Shown Models FSLR18, FSLR24, FDLCR18, FDLCR24, and FDLCR30 Parts List Models CVDA18R, CVDA24R, and CVDA30R KEY Part Number for CVDA18R CVDA24R Models CPVSA18R, and CPVSA24R KEY Part Number for CPVSA18R CPVSA24R Description QTY Accessories Owners Registration Form Postage Required 901273-01D Limited Warranty Vented GAS Logs Warranty Information

CVDA24R, CVDA30R, CPVSA18R, CPVSA24R, CVDA18R specifications

The Desa CVDA18R, CPVSA18R, CPVSA24R, CVDA24R, and CVDA30R are a series of advanced solutions designed to meet various heating and ventilation needs. These models come with a plethora of features, technologies, and characteristics that make them suitable for both residential and commercial applications.

The Desa CVDA18R, a heating powerhouse, boasts an impressive thermal output that ensures rapid heating across medium-sized spaces. It integrates advanced control systems allowing precise temperature regulation for enhanced comfort and energy efficiency. One of its standout technologies is the dual-fuel option, supporting both gas and electric heating, providing versatility depending on availability and preference.

Similarly, the CPVSA18R model stands out with its compact design, ideal for tight spaces without compromising on efficiency. It features a high-efficiency combustion system that maximizes heat production while minimizing fuel consumption. This model also includes an intelligent self-diagnostic system that monitors performance and alerts users to any potential issues, ensuring reliable operation.

The CPVSA24R takes things further with an increased heating capacity suitable for larger spaces. It combines sustainable technologies with user-friendly interfaces, allowing homeowners and businesses to manage their heating systems easily. Features such as programmable timers and remote access via smart devices add convenience in today's tech-driven world.

Next in the lineup, the CVDA24R focuses on improved air quality, equipped with advanced filtration systems that not only heat but also purify the air in living spaces. This model is particularly beneficial for those with allergies or respiratory concerns, ensuring a healthier indoor environment.

Lastly, the CVDA30R brings robust performance to the table, designed for expansive areas that demand high heating capacity. It incorporates sound-dampening technologies, making it one of the quietest units in its class. With a focus on energy efficiency, the CVDA30R meets or exceeds energy performance standards, helping users save on utility bills while contributing to a greener planet.

Overall, the Desa CVDA and CPVSA series exemplify cutting-edge heating technologies, offering a blend of efficiency, reliability, and user comfort. Each model caters to specific needs, ensuring that customers find the right fit for their unique heating challenges.