Desa CVDA18R, CPVSA18R, CPVSA24R, CVDA24R, CVDA30R Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

LOCAL CODES

3

PRODUCT IDENTIFICATION

3

UNPACKING

3

PRODUCT FEATURE

3

INSTALLATION

4

OPERATING APPLIANCE

10

INSPECTING BURNERS

12

CLEANING AND MAINTENANCE

12

REPLACEMENT PARTS

12

TROUBLESHOOTING

13

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

16

ACCESSORIES

28

OWNER'S REGISTRATION FORM

29

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNINGS

WARNING: This product contains chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

WARNING: Keep flue open when operating unit.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.

WARNING: Any change to this log set or its controls can be dangerous.

1.This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is convertible for use with propane/LP.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.Never install the log set

in a recreational vehicle

where curtains, furniture, clothing, or other flammable ob- jects are less than 42 inches from the front, top, or sides of the log set

in high traffic areas

in windy or drafty areas

4.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ig- nite if highly heated. Inspect chimney flue for damage.

5.You must operate this log set with fireplace doors or screens in place and fully closed. Unless provided by other means, fire- place doors or screens shall have openings for introduction of combustion air.

6.This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window.

7.To reduce the creation of soot, follow the instructions in Clean- ing and Maintenance, page 12.

8.Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting.

For morevisit www..com

901273-01D

Image 2
Contents Owners Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLocal Codes Product FeatureRemote Ready Safety VALVE/PILOT Product IdentificationVenting Specifications for Installation InstallationFlue Opening Specifications Check GAS TypeInstallation Items Needed Installing Damper ClampConnecting to GAS Supply Checking GAS Connections Hearth PAN InstallationPressure Testing Gas Supply Piping System Burner Inlet Fitting Adjusting Regulator Pressure For Propane/LP ConversionPropane/LP Gas Conversion Adding PAN Material Testing Burner for LeaksRemote Control Options GWMS2Installing Grate and Logs Installing Grate Pan Material Not ShownOperating Appliance For Your Safety Read Before LightingIf Using Optional Hand-Held Remote or Wall Switch Lighting InstructionsCuring Logs GWMS2 Wall Mounted Switch OptionalTo Turn OFF GAS to Appliance Optional Remote OperationInspecting Burners Cleaning MaintenanceReplacement Parts Troubleshooting Observed Problem Possible Cause RemedyFor more Visit www Com Top Gas leak. See Warning statement atIllustrated Parts Breakdown Models VVSA18R, VVSA24R, VVDA18R VVDA24R, and VVDA30RParts List Parts Available not ShownKingston Split Oak Logs Hanover Round Oak Logs Parts List Illustrated Parts BREAK- Down Models FVSA18R, FVSA24R, FVDA18R FVDA24R, and FVDA30RParts Available not Shown Models FSLR18, FSLR24, FDLCR18, FDLCR24, and FDLCR30 Parts List Models CVDA18R, CVDA24R, and CVDA30R KEY Part Number for CVDA18R CVDA24R Models CPVSA18R, and CPVSA24R KEY Part Number for CPVSA18R CPVSA24R Description QTY Accessories Owners Registration Form Postage Required 901273-01D Warranty Information Limited Warranty Vented GAS Logs

CVDA24R, CVDA30R, CPVSA18R, CPVSA24R, CVDA18R specifications

The Desa CVDA18R, CPVSA18R, CPVSA24R, CVDA24R, and CVDA30R are a series of advanced solutions designed to meet various heating and ventilation needs. These models come with a plethora of features, technologies, and characteristics that make them suitable for both residential and commercial applications.

The Desa CVDA18R, a heating powerhouse, boasts an impressive thermal output that ensures rapid heating across medium-sized spaces. It integrates advanced control systems allowing precise temperature regulation for enhanced comfort and energy efficiency. One of its standout technologies is the dual-fuel option, supporting both gas and electric heating, providing versatility depending on availability and preference.

Similarly, the CPVSA18R model stands out with its compact design, ideal for tight spaces without compromising on efficiency. It features a high-efficiency combustion system that maximizes heat production while minimizing fuel consumption. This model also includes an intelligent self-diagnostic system that monitors performance and alerts users to any potential issues, ensuring reliable operation.

The CPVSA24R takes things further with an increased heating capacity suitable for larger spaces. It combines sustainable technologies with user-friendly interfaces, allowing homeowners and businesses to manage their heating systems easily. Features such as programmable timers and remote access via smart devices add convenience in today's tech-driven world.

Next in the lineup, the CVDA24R focuses on improved air quality, equipped with advanced filtration systems that not only heat but also purify the air in living spaces. This model is particularly beneficial for those with allergies or respiratory concerns, ensuring a healthier indoor environment.

Lastly, the CVDA30R brings robust performance to the table, designed for expansive areas that demand high heating capacity. It incorporates sound-dampening technologies, making it one of the quietest units in its class. With a focus on energy efficiency, the CVDA30R meets or exceeds energy performance standards, helping users save on utility bills while contributing to a greener planet.

Overall, the Desa CVDA and CPVSA series exemplify cutting-edge heating technologies, offering a blend of efficiency, reliability, and user comfort. Each model caters to specific needs, ensuring that customers find the right fit for their unique heating challenges.