INSTALLATION
Hearth Kit Installation (Cont.)
7
INSTALLATION
Continued
Propane/LP Gas Conversion
To convert to propane/LP gas, the regulator pressure must be reset. Also, the burner inlet fitting and pilot orifice must be replaced. The propane/LP burner inlet fitting is supplied with the orifice installed for your log set.
Burner Inlet Fitting
1.Remove the pilot assembly from the valve cover by removing the two screws on the bracket (see Figure 7).
2.Unscrew and remove piezo ignitor and ignitor cover from valve cover.
3.Remove the two (2) screws on the burner pan and the remaining screw on the rear of the control valve to remove valve cover.
4.Unthread control valve and burner inlet fitting from burner tube by turning valve
5.Remove natural gas inlet fitting from the control valve and discard (see Figure 8). DO NOT remove the orifice from this fitting. The propane/LP burner inlet fitting is included in the hardware kit (see Figure 11, page 8).
Pilot
Thermocouple Bracket
Assembly
Screw
Burner Pan
Ignitor
| O |
N | F |
O | F |
TO L P |
Machine
|
|
| Piezo Ignitor Screw |
| O |
| Cover |
NO | FF | Valve |
|
|
|
| |
|
| Cover |
|
Piezo Ignitor
Figure 7 - Removing/Installing Thermocouple, Pilot, and Piezo Ignitor Cover
Burner Inlet Fitting |
|
|
for Natural Gas |
| O |
| ON | FF |
Figure 8 - Remove Burner Inlet Fitting
6.Be sure to use the correct orifice for your appliance. The orifice kit included with this appliance contains an orifice installed in an air mixer fitting.
7.Using thread sealant (resistant to the action of propane/LP gas) on smaller end of fitting, screw the burner inlet fitting into the outlet side of the gas control. Tighten using a wrench.
8 . Rethread the valve and fitting assembly into the burner tube until fully threaded and level with the burner pan. Reattach the valve cover with the three (3) screws previously removed in step 3.
Injector for | Injector for | |
Natural | ||
Propane/LP | ||
Gas | ||
Gas | ||
| ||
NATURAL | PROPANE/LP | |
GAS FITTING | GAS FITTING |
Figure 9 - Burner Inlet Fittings with Injectors
Adjusting Regulator Pressure For Propane/LP Conversion
1.Locate the pressure button on regulator tower of gas control valve.
2.Remove the pressure button from the regulator tower (see Figure 10).
3.Reverse the pressure button and replace into regulator tower (see Figure 11).
Gas Control Valve
Pressure
Button
| O | |
| F | |
N | F | |
O |
| |
Regulator | IP | |
TOL | ||
| ||
Tower |
|
Figure 10 - Removing Pressure Button
Gas Control Valve
Pressure
Button
| O |
| F |
N | F |
O |
|
Regulator | IP |
TOL | |
Tower |
|
Figure 11 - Replacing the Pressure Button in the Propane/LP position
For more information, visit www.desatech.com