Desa CVDA24R, CVDA30R, CPVSA18R, CPVSA24R, CVDA18R Propane/LP Gas Conversion, Burner Inlet Fitting

Page 7

INSTALLATION

Hearth Kit Installation (Cont.)

7

INSTALLATION

Continued

Propane/LP Gas Conversion

To convert to propane/LP gas, the regulator pressure must be reset. Also, the burner inlet fitting and pilot orifice must be replaced. The propane/LP burner inlet fitting is supplied with the orifice installed for your log set.

Burner Inlet Fitting

1.Remove the pilot assembly from the valve cover by removing the two screws on the bracket (see Figure 7).

2.Unscrew and remove piezo ignitor and ignitor cover from valve cover.

3.Remove the two (2) screws on the burner pan and the remaining screw on the rear of the control valve to remove valve cover.

4.Unthread control valve and burner inlet fitting from burner tube by turning valve counter-clockwise (see Figure 8) .

5.Remove natural gas inlet fitting from the control valve and discard (see Figure 8). DO NOT remove the orifice from this fitting. The propane/LP burner inlet fitting is included in the hardware kit (see Figure 11, page 8).

Pilot

Thermocouple Bracket

Assembly

Screw

Burner Pan

Ignitor

 

O

N

F

O

F

TO L P

Machine

 

 

 

Piezo Ignitor Screw

 

O

 

Cover

NO

FF

Valve

 

 

 

 

 

 

Cover

 

Piezo Ignitor

Figure 7 - Removing/Installing Thermocouple, Pilot, and Piezo Ignitor Cover

Burner Inlet Fitting

 

 

for Natural Gas

 

O

 

ON

FF

Figure 8 - Remove Burner Inlet Fitting

6.Be sure to use the correct orifice for your appliance. The orifice kit included with this appliance contains an orifice installed in an air mixer fitting.

7.Using thread sealant (resistant to the action of propane/LP gas) on smaller end of fitting, screw the burner inlet fitting into the outlet side of the gas control. Tighten using a wrench.

8 . Rethread the valve and fitting assembly into the burner tube until fully threaded and level with the burner pan. Reattach the valve cover with the three (3) screws previously removed in step 3.

Injector for

Injector for

Natural

Propane/LP

Gas

Gas

 

NATURAL

PROPANE/LP

GAS FITTING

GAS FITTING

Figure 9 - Burner Inlet Fittings with Injectors

Adjusting Regulator Pressure For Propane/LP Conversion

1.Locate the pressure button on regulator tower of gas control valve.

2.Remove the pressure button from the regulator tower (see Figure 10).

3.Reverse the pressure button and replace into regulator tower (see Figure 11).

Gas Control Valve

Pressure

Button

 

O

 

F

N

F

O

 

Regulator

IP

TOL

 

Tower

 

Figure 10 - Removing Pressure Button

Gas Control Valve

Pressure

Button

 

O

 

F

N

F

O

 

Regulator

IP

TOL

Tower

 

Figure 11 - Replacing the Pressure Button in the Propane/LP position

For more information, visit www.desatech.com

901273-01D

Image 7
Contents What to do if YOU Smell GAS Owners Operation and Installation ManualSafety Information Table of ContentsProduct Identification Product FeatureRemote Ready Safety VALVE/PILOT Local Codes Check GAS Type Installation Flue Opening Specifications Venting Specifications for InstallationConnecting to GAS Supply Installing Damper ClampInstallation Items Needed Pressure Testing Gas Supply Piping System Hearth PAN InstallationChecking GAS Connections Propane/LP Gas Conversion Adjusting Regulator Pressure For Propane/LP ConversionBurner Inlet Fitting GWMS2 Testing Burner for LeaksRemote Control Options Adding PAN MaterialInstalling Grate Pan Material Not Shown Installing Grate and LogsLighting Instructions For Your Safety Read Before LightingIf Using Optional Hand-Held Remote or Wall Switch Operating ApplianceOptional Remote Operation GWMS2 Wall Mounted Switch OptionalTo Turn OFF GAS to Appliance Curing LogsReplacement Parts Cleaning MaintenanceInspecting Burners Observed Problem Possible Cause Remedy TroubleshootingFor more Visit www Com Gas leak. See Warning statement at TopModels VVSA18R, VVSA24R, VVDA18R VVDA24R, and VVDA30R Illustrated Parts BreakdownParts Available not Shown Parts ListKingston Split Oak Logs Hanover Round Oak Logs Parts List Models FVSA18R, FVSA24R, FVDA18R FVDA24R, and FVDA30R Illustrated Parts BREAK- DownParts Available not Shown Models FSLR18, FSLR24, FDLCR18, FDLCR24, and FDLCR30 Parts List Models CVDA18R, CVDA24R, and CVDA30R KEY Part Number for CVDA18R CVDA24R Models CPVSA18R, and CPVSA24R KEY Part Number for CPVSA18R CPVSA24R Description QTY Accessories Owners Registration Form Postage Required 901273-01D Limited Warranty Vented GAS Logs Warranty Information