OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
25
OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
For Masonry and Factory-built Metal Fireplace
If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb else- where, an
Tools needed: 1/4" hex driver or socket
1. | Remove logs. Locate the gas valve assembly and thermostat |
| sensing bulb (see Figure 43). |
2. | With 1/4" hex driver or socket, loosen the thermostat screw. |
| Carefully slide the thermostat sensing bulb out of the retaining |
| clamp (see Figure 45). |
| Note: Do not remove the screw. Make sure you tighten the |
| screw after removing the thermostat sensing bulb. |
| IMPORTANT: Do not force or bend the thermostat sensing |
Figure 44 - Adhesive-backed Mounting Clip
Capillary | Thermostat | |
Screw | ||
| ||
Retaining |
| |
Clamp |
| |
| Thermostat | |
| Sensing Bulb |
Figure 45 - Removing Thermostat Sensing Bulb
bulb or capillary. |
3. The thermostat sensing bulb may be located to the lower right |
front side of fireplace. Determine location of sensing bulb, but |
do not mount sensing bulb until step 5. If you have a masonry |
fireplace, see Figure 46 for location. If you have a |
metal fireplace, see Figure 47 for location. If your fireplace |
has glass doors, position sensing bulb directly behind door gap |
on right bottom side (see Figure 48). |
Thermostat Sensing Bulb
Adhesive- backed Mounting Clip
Thermostat Sensing Bulb
Adhesive- backed Mounting Clip
4. The mounting clip must be a minimum of 3" from bottom of |
fireplace to prevent crimping of capillary. Once you have de- |
cided on a location, clean the area thoroughly. Remove the pa- |
per backing from the adhesive on back of mounting clip. Press |
Figure 46- Locating Thermo- | Figure 47 - Locating Thermo- |
stat Sensing Bulb on Masonry | stat Sensing Bulb on Factory- |
Fireplace | built Metal Fireplace |
the clip into the new location so that the thermostat sensing bulb |
will be positioned vertically with the capillary at the bottom |
(see Figure 49). Slide the thermostat sensing bulb into the clip. |
IMPORTANT: Do not crimp capillary. |
Gas Valve
Assembly
Thermostat
Sensing
Bulb
Adhesive- backed Mounting
Clip
Glass Doors
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Capillary
Mounting | Thermostat | |
Sensing Bulb | ||
Bracket | ||
|
Figure 43 - Location of Gas Valve Assembly and Thermostat Sensing Bulb
Figure 48 - Installing Ther- | Figure 49 - Positioning the | |
Thermostat Sensing Bulb in | ||
mostat Sensing Bulb behind | ||
the Vertical Position with the | ||
Glass Doors | ||
Capillary at the Bottom | ||
|