Desa CFN2800BTB, VN2800BTB installation manual Correct Burner Flame Pattern

Page 21

INSPECTING BURNER

Continued

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

WARNING

WARNING ICON

G 001

If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 20 - Correct Burner Flame Pattern

Yellow

Tipping

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 21 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance, page 19).

see Troubleshooting, pages 22 through 25.

101809

21

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Contents001 Product Identification FeaturesLocal Codes UnpackingAIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsInstallation Items Installing to WallCheck GAS Type Locating HeaterThermostat Sensing Bulb Locating Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Mounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsUse pipe joint sealant that is resistant to natural gas Connecting to GAS SupplyChecking GAS Pressure Testing GAS Supply Piping SystemConnections Servicing. Correct all leaks at onceChecking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingOperating Heater Shutting Off Burner Only pilot stays lit Shutting Off HeaterPilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternTrouble Shooting ODS/PILOT and BurnerCabinet Trouble Cleaning and MainteTROUBLE- Shooting Shut off gas supply If you smell gasDo not try to light any appliance Ing statement atService Hints Technical ServiceService Publications Parts Under WarrantyParts Not Under Warranty VN2000BTB CFN2000BTB VN2800BTB CFN2800BTB Parts List FAN Kits GA3100A, and GA3200TA AccessoriesModel VN2000BTB GA4000B Model VN2800BTB GA4010B Valve GA5010101809 Keep this Warranty Warranty Information

VN2800BTB, CFN2800BTB specifications

Desa CFN2800BTB and VN2800BTB stand as premium heating solutions in the contemporary market, delivering superior warmth and user-friendly features to enhance any living environment. These models are characterized by their advanced technology, ergonomic design, and energy efficiency, making them ideal for both residential and commercial spaces.

One of the standout features of the CFN2800BTB and VN2800BTB is their innovative infrared heating technology. Unlike traditional convection heaters that warm the air, these units emit infrared rays that directly heat objects and people in the room. This not only results in faster heating but also ensures a more consistent warmth, allowing users to enjoy a comfortable ambiance even in larger spaces.

Moreover, these models boast a compact and stylish design, making them versatile for various room aesthetics. Their sleek appearance ensures that they can seamlessly blend into any decor without being obtrusive. The lightweight construction also facilitates easy relocation, allowing users to position the heater where it is most needed.

Energy efficiency is a key characteristic of the CFN2800BTB and VN2800BTB. Both units are designed to provide maximum warmth with minimal energy consumption. They feature adjustable heat settings, allowing users to customize the heating level to their needs, which not only contributes to comfort but also helps in reducing electricity bills. The built-in thermostat ensures that the heater maintains a consistent temperature, further optimizing energy use.

Safety is another paramount concern with these models. They come equipped with multiple safety features, including overheat protection and tip-over switches, which automatically turn the heater off in case of an accidental fall or overheating. This ensures peace of mind for users, particularly in homes with pets and children.

In conclusion, the Desa CFN2800BTB and VN2800BTB are exemplary heating solutions that combine modern technology with safety and efficiency. Their infrared heating capability, stylish design, and focus on user comfort make them standout products in the competitive heating appliance market. Whether for personal use or as an ideal solution for larger spaces, these models promise reliability and superior performance.