Desa CFN2800BTB, VN2800BTB Ventilation AIR, Ventilation Air From Inside Building

Page 7

AIR FOR COMBUSTION AND VENTILATION

Continued

WARNING

WARNING ICON

G 001

If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING

WARNING ICON

G 001

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

12"

Figure 2 - Ventilation Air from Inside Building

Continued

101809

7

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Contents001 Unpacking FeaturesProduct Identification Local CodesVentilation AIR for CombustionProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsLocating Heater Installing to WallInstallation Items Check GAS TypeLocating Thermostat Sensing Bulb Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Methods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsUse pipe joint sealant that is resistant to natural gas Connecting to GAS SupplyServicing. Correct all leaks at once Pressure Testing GAS Supply Piping SystemChecking GAS ConnectionsChecking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingOperating Heater Shutting Off Burner Only pilot stays lit Shutting Off HeaterPilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternODS/PILOT and Burner Trouble ShootingCabinet Trouble Cleaning and MainteTROUBLE- Shooting Ing statement at If you smell gasShut off gas supply Do not try to light any applianceService Hints Technical ServiceParts Under Warranty Service PublicationsParts Not Under Warranty VN2000BTB CFN2000BTB VN2800BTB CFN2800BTB Parts List Valve GA5010 AccessoriesFAN Kits GA3100A, and GA3200TA Model VN2000BTB GA4000B Model VN2800BTB GA4010B101809 Keep this Warranty Warranty Information

VN2800BTB, CFN2800BTB specifications

Desa CFN2800BTB and VN2800BTB stand as premium heating solutions in the contemporary market, delivering superior warmth and user-friendly features to enhance any living environment. These models are characterized by their advanced technology, ergonomic design, and energy efficiency, making them ideal for both residential and commercial spaces.

One of the standout features of the CFN2800BTB and VN2800BTB is their innovative infrared heating technology. Unlike traditional convection heaters that warm the air, these units emit infrared rays that directly heat objects and people in the room. This not only results in faster heating but also ensures a more consistent warmth, allowing users to enjoy a comfortable ambiance even in larger spaces.

Moreover, these models boast a compact and stylish design, making them versatile for various room aesthetics. Their sleek appearance ensures that they can seamlessly blend into any decor without being obtrusive. The lightweight construction also facilitates easy relocation, allowing users to position the heater where it is most needed.

Energy efficiency is a key characteristic of the CFN2800BTB and VN2800BTB. Both units are designed to provide maximum warmth with minimal energy consumption. They feature adjustable heat settings, allowing users to customize the heating level to their needs, which not only contributes to comfort but also helps in reducing electricity bills. The built-in thermostat ensures that the heater maintains a consistent temperature, further optimizing energy use.

Safety is another paramount concern with these models. They come equipped with multiple safety features, including overheat protection and tip-over switches, which automatically turn the heater off in case of an accidental fall or overheating. This ensures peace of mind for users, particularly in homes with pets and children.

In conclusion, the Desa CFN2800BTB and VN2800BTB are exemplary heating solutions that combine modern technology with safety and efficiency. Their infrared heating capability, stylish design, and focus on user comfort make them standout products in the competitive heating appliance market. Whether for personal use or as an ideal solution for larger spaces, these models promise reliability and superior performance.