Desa VN2800BTB, CFN2800BTB installation manual Checking, Pressure Testing Heater GAS Connections

Page 16

CHECKING

4.

Check all joints of gas supply piping system. Apply mixture of liquid soap and

GAS

 

water to gas joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

CONNECTIONS

Test Pressures Equal To or Less Than 1/2 PSIG

Continued

1.

Close manual shutoff valve (see Figure 14).

 

2.

Pressurize supply piping system by either using compressed air or opening main

 

 

gas valve located on or near gas meter.

 

3.

Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply

 

 

mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

 

4.

Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open manual shutoff valve (see Figure 14).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to thermostat gas valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 17 through 19). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 19).

8.Replace front panel.

Open

Manual

Shutoff

Valve

Closed

Figure 14 - Manual Shutoff Valve

Thermostat Gas Valve

Gas Meter

Manual

Shutoff

Valve

16

Figure 15 - Checking Gas Joints

101809

Image 16
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information001 Features Product IdentificationLocal Codes UnpackingVentilation AIR for CombustionProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsInstalling to Wall Installation ItemsCheck GAS Type Locating HeaterLocating Thermostat Sensing Bulb Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Installing Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Use pipe joint sealant that is resistant to natural gasPressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterOperating Heater Shutting Off Heater Shutting Off Burner Only pilot stays litInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternODS/PILOT and Burner Trouble ShootingCabinet Cleaning and Mainte TroubleTROUBLE- Shooting If you smell gas Shut off gas supplyDo not try to light any appliance Ing statement atTechnical Service Service HintsParts Under Warranty Service PublicationsParts Not Under Warranty VN2000BTB CFN2000BTB VN2800BTB CFN2800BTB Parts List Accessories FAN Kits GA3100A, and GA3200TAModel VN2000BTB GA4000B Model VN2800BTB GA4010B Valve GA5010101809 Warranty Information Keep this Warranty

VN2800BTB, CFN2800BTB specifications

Desa CFN2800BTB and VN2800BTB stand as premium heating solutions in the contemporary market, delivering superior warmth and user-friendly features to enhance any living environment. These models are characterized by their advanced technology, ergonomic design, and energy efficiency, making them ideal for both residential and commercial spaces.

One of the standout features of the CFN2800BTB and VN2800BTB is their innovative infrared heating technology. Unlike traditional convection heaters that warm the air, these units emit infrared rays that directly heat objects and people in the room. This not only results in faster heating but also ensures a more consistent warmth, allowing users to enjoy a comfortable ambiance even in larger spaces.

Moreover, these models boast a compact and stylish design, making them versatile for various room aesthetics. Their sleek appearance ensures that they can seamlessly blend into any decor without being obtrusive. The lightweight construction also facilitates easy relocation, allowing users to position the heater where it is most needed.

Energy efficiency is a key characteristic of the CFN2800BTB and VN2800BTB. Both units are designed to provide maximum warmth with minimal energy consumption. They feature adjustable heat settings, allowing users to customize the heating level to their needs, which not only contributes to comfort but also helps in reducing electricity bills. The built-in thermostat ensures that the heater maintains a consistent temperature, further optimizing energy use.

Safety is another paramount concern with these models. They come equipped with multiple safety features, including overheat protection and tip-over switches, which automatically turn the heater off in case of an accidental fall or overheating. This ensures peace of mind for users, particularly in homes with pets and children.

In conclusion, the Desa CFN2800BTB and VN2800BTB are exemplary heating solutions that combine modern technology with safety and efficiency. Their infrared heating capability, stylish design, and focus on user comfort make them standout products in the competitive heating appliance market. Whether for personal use or as an ideal solution for larger spaces, these models promise reliability and superior performance.