Desa VN2800BTB, CFN2800BTB installation manual Operating Heater

Page 18
C-clockwise
C-clockwise

18

OPERATING HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 16).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 22 through

25.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 19.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 17 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified

service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION

WARNING ICON

G 001

Do not try to adjust heating levels by using the manual shutoff valve.

101809

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information001 Local Codes FeaturesProduct Identification UnpackingAIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsCheck GAS Type Installing to WallInstallation Items Locating HeaterThermostat Sensing Bulb Locating Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Removing Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Use pipe joint sealant that is resistant to natural gasConnections Pressure Testing GAS Supply Piping SystemChecking GAS Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterOperating Heater Shutting Off Heater Shutting Off Burner Only pilot stays litInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternTrouble Shooting ODS/PILOT and BurnerCabinet Cleaning and Mainte TroubleTROUBLE- Shooting Do not try to light any appliance If you smell gasShut off gas supply Ing statement atTechnical Service Service HintsService Publications Parts Under WarrantyParts Not Under Warranty VN2000BTB CFN2000BTB VN2800BTB CFN2800BTB Parts List Model VN2000BTB GA4000B Model VN2800BTB GA4010B AccessoriesFAN Kits GA3100A, and GA3200TA Valve GA5010101809 Warranty Information Keep this Warranty

VN2800BTB, CFN2800BTB specifications

Desa CFN2800BTB and VN2800BTB stand as premium heating solutions in the contemporary market, delivering superior warmth and user-friendly features to enhance any living environment. These models are characterized by their advanced technology, ergonomic design, and energy efficiency, making them ideal for both residential and commercial spaces.

One of the standout features of the CFN2800BTB and VN2800BTB is their innovative infrared heating technology. Unlike traditional convection heaters that warm the air, these units emit infrared rays that directly heat objects and people in the room. This not only results in faster heating but also ensures a more consistent warmth, allowing users to enjoy a comfortable ambiance even in larger spaces.

Moreover, these models boast a compact and stylish design, making them versatile for various room aesthetics. Their sleek appearance ensures that they can seamlessly blend into any decor without being obtrusive. The lightweight construction also facilitates easy relocation, allowing users to position the heater where it is most needed.

Energy efficiency is a key characteristic of the CFN2800BTB and VN2800BTB. Both units are designed to provide maximum warmth with minimal energy consumption. They feature adjustable heat settings, allowing users to customize the heating level to their needs, which not only contributes to comfort but also helps in reducing electricity bills. The built-in thermostat ensures that the heater maintains a consistent temperature, further optimizing energy use.

Safety is another paramount concern with these models. They come equipped with multiple safety features, including overheat protection and tip-over switches, which automatically turn the heater off in case of an accidental fall or overheating. This ensures peace of mind for users, particularly in homes with pets and children.

In conclusion, the Desa CFN2800BTB and VN2800BTB are exemplary heating solutions that combine modern technology with safety and efficiency. Their infrared heating capability, stylish design, and focus on user comfort make them standout products in the competitive heating appliance market. Whether for personal use or as an ideal solution for larger spaces, these models promise reliability and superior performance.