036-21044-003-A-0304

TABLE 8: COOLING CAPACITY 12-1/2 TON UNIT - IMPERIAL

Air On

 

Temperature of Air on Condenser Coil 85°F

 

 

Temperature of Air on Condenser Coil 95°F

 

Evap. Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB

Tot.

 

Tot.

 

Sensible Capacity (MBH)1

 

Tot.

 

Tot.

 

 

Sensible Capacity (MBH)1

 

CFM

Cap.1

 

Input2

 

Return Dry Bulb (°F)

 

Cap.1

 

Input2

 

 

Return Dry Bulb (°F)

 

 

(°F)

 

 

 

 

 

 

 

 

 

 

(MBH)

 

(kW)

86

83

80

77

74

71

68

(MBH)

 

(kW)

86

 

83

80

77

74

 

71

68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

150

 

11.8

90

80

69

58

47

-

-

143

 

13.0

88

 

78

67

56

45

 

-

-

3750

67

140

 

11.5

115

104

94

83

72

61

51

132

 

12.6

111

 

101

90

79

69

 

58

47

62

123

 

11.2

123

116

105

95

84

73

63

117

 

12.4

117

 

112

102

91

80

 

70

59

 

 

 

 

 

 

57

118

 

11.3

118

116

105

95

84

73

63

111

 

12.5

111

 

111

100

90

79

 

68

57

 

72

155

 

11.8

101

88

75

63

50

-

-

148

 

13.0

98

 

86

73

61

48

 

-

-

4375

67

145

 

11.5

128

115

102

90

77

64

52

137

 

12.5

124

 

111

99

86

73

 

61

48

62

127

 

11.2

127

124

115

103

90

77

65

121

 

12.4

121

 

119

111

99

86

 

73

61

 

 

 

 

 

 

57

122

 

11.3

122

121

115

103

90

77

65

115

 

12.4

115

 

115

110

97

84

 

72

59

 

72

161

 

11.8

111

96

82

67

53

-

-

153

 

12.9

109

 

94

80

65

50

 

-

-

5000

67

150

 

11.5

140

126

111

97

82

67

53

142

 

12.5

136

 

122

107

92

78

 

63

49

62

132

 

11.3

132

132

125

111

96

82

67

125

 

12.3

125

 

125

121

106

92

 

77

63

 

 

 

 

 

 

57

126

 

11.3

126

126

125

111

96

82

67

119

 

12.4

119

 

119

119

105

90

 

75

61

 

72

165

 

11.9

132

115

99

82

65

-

-

157

 

13.1

129

 

112

95

79

62

 

-

-

5625

67

153

 

11.6

149

141

134

118

101

84

68

146

 

12.6

143

 

136

128

112

95

 

79

62

62

135

 

11.3

135

135

132

115

98

82

65

129

 

12.5

129

 

129

126

110

93

 

77

60

 

 

 

 

 

 

57

129

 

11.4

129

129

129

112

96

79

62

123

 

12.5

123

 

123

123

106

89

 

73

56

 

72

169

 

11.9

153

134

116

97

78

-

-

162

 

13.2

148

 

130

111

93

74

 

-

-

6250

67

157

 

11.6

157

157

157

138

120

101

83

150

 

12.8

150

 

150

150

131

112

 

94

75

62

138

 

11.4

138

138

138

119

101

82

63

132

 

12.6

132

 

132

132

113

95

 

76

58

 

 

 

 

 

 

57

133

 

11.4

133

133

133

114

95

77

58

126

 

12.7

126

 

126

126

107

89

 

70

51

 

 

 

 

Temperature

of

Air on

Condenser Coil 105°F

 

 

 

Temperature of Air on Condenser Coil 115°F

 

 

72

135

 

14.3

86

75

64

54

43

-

-

127

 

15.6

83

 

72

62

51

40

 

-

-

3750

67

124

 

13.8

108

97

87

76

65

55

44

117

 

15.1

105

 

94

83

73

62

 

51

41

62

110

 

13.6

110

108

97

86

75

65

54

103

 

14.9

103

 

103

92

81

71

 

60

49

 

 

 

 

 

 

57

105

 

13.8

105

105

94

84

73

62

52

99

 

15.0

99

 

99

89

78

67

 

57

46

 

72

139

 

14.3

96

83

70

58

45

-

-

131

 

15.6

93

 

80

67

55

42

 

-

-

4375

67

129

 

13.8

119

108

95

82

70

57

44

121

 

15.1

115

 

104

91

79

66

 

53

41

62

114

 

13.6

114

113

106

93

81

68

56

107

 

14.9

107

 

106

101

88

76

 

63

50

 

 

 

 

 

 

57

109

 

13.7

109

109

103

91

78

66

53

103

 

15.0

103

 

103

97

85

72

 

59

47

 

72

144

 

14.3

106

91

76

62

47

-

-

135

 

15.6

102

 

88

73

59

44

 

-

-

5000

67

133

 

13.8

130

118

103

89

74

59

45

124

 

15.1

124

 

114

99

85

70

 

56

41

62

118

 

13.6

118

118

115

101

86

72

57

110

 

14.9

110

 

110

110

95

80

 

66

51

 

 

 

 

 

 

57

113

 

13.7

113

113

112

98

83

69

54

106

 

15.0

106

 

106

106

91

76

 

62

47

 

72

148

 

14.4

121

105

88

72

55

-

-

138

 

15.7

114

 

98

81

64

48

 

-

-

5625

67

136

 

13.9

135

129

119

103

86

69

53

127

 

15.2

127

 

122

110

93

77

 

60

43

62

120

 

13.7

120

120

119

103

86

69

53

112

 

15.0

112

 

112

112

95

79

 

62

46

 

 

 

 

 

 

57

115

 

13.8

115

115

115

99

82

65

49

108

 

15.1

108

 

108

108

91

75

 

58

41

 

72

151

 

14.5

137

119

100

81

63

-

-

140

 

15.8

126

 

107

89

70

52

 

-

-

6250

67

139

 

14.0

139

139

135

116

98

79

61

129

 

15.3

129

 

129

120

102

83

 

65

46

62

123

 

13.8

123

123

123

105

86

67

49

115

 

15.0

115

 

115

115

96

77

 

59

40

 

 

 

 

 

 

57

118

 

13.9

118

118

118

99

81

62

43

110

 

15.2

110

 

110

110

91

73

 

54

36

 

 

 

 

Temperature

of

Air on

Condenser Coil 125°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

119

 

16.9

80

70

59

48

37

-

-

1 These capacities are gross ratings. For net

 

3750

67

109

 

16.4

101

91

80

69

59

48

37

 

 

 

 

capacity, deduct air blower motor, MBH = 3.415

 

62

97

 

16.1

97

97

87

77

66

55

44

 

 

 

 

 

 

 

 

 

 

 

 

x kW. Refer to the appropriate Blower Perfor-

 

 

57

93

 

16.3

93

93

83

72

62

51

40

 

 

 

 

72

122

 

16.9

90

77

64

52

39

-

-

 

 

mance Table for the kW of the supply air

 

 

4375

67

112

 

16.4

110

100

88

75

62

50

37

 

 

blower motor.

 

 

 

 

 

 

 

62

100

 

16.1

100

100

96

83

70

58

45

2

 

These ratings include condenser fan motors

 

 

 

 

 

 

57

96

 

16.3

96

96

91

78

66

53

40

 

 

and the compressor motors but not the supply

 

 

72

126

 

16.9

99

85

70

56

41

-

-

 

 

 

 

 

 

 

air blower motor.

 

 

 

 

 

 

 

5000

67

115

 

16.4

115

110

95

81

66

52

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

102

 

16.1

102

102

102

89

75

60

46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

99

 

16.3

99

99

99

84

70

55

41

 

 

 

 

 

 

 

 

 

 

 

 

 

72

128

 

17.0

107

91

74

57

41

-

-

 

 

 

 

 

 

 

 

 

 

 

 

5625

67

117

 

16.5

117

115

101

84

67

51

34

 

 

 

 

 

 

 

 

 

 

 

 

62

104

 

16.2

104

104

104

88

72

55

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

101

 

16.4

101

101

101

84

67

51

34

 

 

 

 

 

 

 

 

 

 

 

 

 

72

130

 

17.1

115

96

78

59

40

-

-

 

 

 

 

 

 

 

 

 

 

 

 

6250

67

119

 

16.5

119

119

106

87

69

50

31

 

 

 

 

 

 

 

 

 

 

 

 

62

106

 

16.3

106

106

106

87

69

50

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

102

 

16.5

102

102

102

84

65

46

28

 

 

 

 

 

 

 

 

 

 

 

 

18

Unitary Products

Page 18
Image 18
York DM150, DM120 manual Cooling Capacity 12-1/2 TON Unit Imperial, 4375, 5625, 6250

DM120, DM150 specifications

The York DM120 and DM150 are advanced rooftop packaged units designed for commercial applications, offering high efficiency, reliability, and user-friendly features. These models are part of York's extensive range of HVAC solutions, aimed at meeting diverse heating, ventilation, and air conditioning needs.

One prominent feature of both the DM120 and DM150 is their streamlined, compact design, which allows for easy installation and fits seamlessly onto rooftops. These units are engineered to maximize space while ensuring high performance. With their robust construction, they are built to withstand harsh weather conditions, ensuring longevity and durability.

The DM120 is designed to provide a cooling capacity of up to 12 tons, whereas the DM150 can reach up to 15 tons. Both models utilize environmentally friendly refrigerants, which contribute to reducing the overall carbon footprint. This makes them a sustainable choice for businesses looking to enhance their environmental responsibility.

In terms of efficiency, both units are equipped with high-efficiency scroll compressors that optimize energy usage, lowering operational costs. They also feature advanced heat exchanger designs that enhance heat transfer efficiency, ensuring consistent indoor comfort while minimizing energy consumption.

User-friendly controls are another hallmark of the York DM120 and DM150. They come with an intuitive interface that allows for easy adjustments and monitoring of system performance. Advanced controls support integration with building management systems, enabling remote monitoring and control for enhanced operational efficiency.

The DM120 and DM150 also prioritize indoor air quality. They incorporate advanced filtration systems that capture airborne particles and improve ventilation, contributing to healthier indoor environments. Furthermore, these models come with variable-speed fans that adjust airflow based on current conditions, optimizing comfort while reducing noise levels.

The models are also designed for serviceability, allowing technicians easy access to critical components for maintenance. This feature not only prolongs the lifespan of the units but also minimizes downtime, keeping commercial spaces comfortable and operational.

In summary, the York DM120 and DM150 units represent an ideal balance of efficiency, technology, and reliability, making them suitable for various commercial applications. Their robust features, commitment to sustainability, and focus on user convenience make them a valuable investment for businesses seeking to improve their HVAC systems.