TABLE 2: CAPACITY RATINGS IMPERIAL

 

Model

 

Cooling Capacity

 

 

Nominal

 

Gas Heat Capacity

 

 

 

 

 

 

Sound

Electric

 

 

 

 

 

 

(80 / 67-95°F)

 

 

 

 

 

 

 

 

 

 

Rating

Heat

Input

Output

Temp

Gas Line

 

 

 

 

 

 

 

(dB)

Capacity

Size

Cooling Cap. (MBH)

Options

MBH

EER

 

(MBH)

(MBH)

Rise (°F)

 

 

(kW)1

(in. OD)

 

 

 

 

 

 

 

DM

89

9.00

87

7, 14,

-

-

-

-

 

 

18, 27

 

 

 

 

 

 

 

 

 

 

 

 

090

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

-

-

-

-

120

96

15-45

3/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

-

-

-

-

180

144

30-60

3/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DM

116

9.0

85

14, 18,

-

-

-

-

120

 

27, 41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

-

-

-

-

180

144

20-50

3/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DM

138

9.0

84

14, 18,

-

-

-

-

150

 

27, 41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

-

-

-

-

180

144

10-40

3/4

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Electric heaters rated at 415V. See tables 10 through 12 for kW ratings at 380V.

TABLE 3: CAPACITY RATINGS METRIC

Model

 

 

Cooling Capacity

 

Nominal

 

Gas Heat Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound

Electric

 

 

 

 

 

 

 

 

(27/19-35°C)

 

 

 

 

 

 

 

 

Rating

Heat

Input

Output

Temp

 

Gas Line

 

 

 

 

 

 

 

 

 

 

 

(dB)

Capacity

Rise

 

Size

Cooling Cap.

Options

kW

CoP2

(kW)

(kW)

 

 

(kW)1

(°C)

 

(mm. OD)

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DM

26.1

2.64

87

7, 14,

 

-

-

 

-

 

18, 27

 

 

090

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(26.4)

10

 

-

-

-

-

35.1

28.1

8.3-25

 

19.05

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

-

-

-

-

52.7

42.2

17-33

 

19.05

 

 

 

 

 

 

 

 

 

 

 

 

120

DM

34.0

2.64

85

14, 18,

-

-

-

 

-

27, 41

 

 

 

 

 

 

 

 

 

 

 

(35.1)

 

 

 

 

 

 

 

 

 

 

 

15

 

-

-

-

-

52.7

42.2

11-28

 

19.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

DM

40.4

2.64

84

14, 18,

-

-

-

 

-

27, 41

 

 

 

 

 

 

 

 

 

 

 

(43.9)

 

 

 

 

 

 

 

 

 

 

 

15

 

-

-

-

-

52.7

42.2

5.6-22

 

19.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Electric heaters rated at 415V. See tables 10 through 12 for kW ratings at 380V