TABLE 5: COOLING CAPACITY 26.4 KW UNIT - METRIC
Air On |
| Temperature of Air on Condenser Coil 29°C |
|
| Temperature of Air on Condenser Coil 35°C |
| ||||||||||||||||||||
Evap. Coil |
|
|
|
| ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| WB | Tot. |
| Tot. |
| Sensible Capacity (kW)1 |
| Tot. |
| Tot. |
|
| Sensible Capacity (kW)1 |
| ||||||||||||
m3/s | Cap.1 |
| Input2 |
|
| Return Dry Bulb (°F) |
|
| Cap.1 |
| Input2 |
|
|
| Return Dry Bulb (°C) |
|
| |||||||||
(°C) |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
| (kW) |
| (kW) | 30 | 28 |
| 27 | 25 | 23 |
| 22 | 20 | (kW) |
| (kW) | 30 |
| 28 |
| 27 | 25 | 23 |
| 22 | 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 22 | 31 |
| 8.6 | 18 | 16 |
| 14 | 12 | 10 |
| - | - | 29 |
| 9.2 | 17 |
| 15 |
| 13 | 11 | 9 |
| - | - |
1.06 | 19 | 28 |
| 8.4 | 22 | 20 |
| 18 | 16 | 14 |
| 12 | 10 | 26 |
| 9.0 | 21 |
| 19 |
| 17 | 15 | 13 |
| 11 | 9 |
17 | 26 |
| 8.2 | 26 | 24 |
| 22 | 20 | 18 |
| 16 | 14 | 24 |
| 8.6 | 24 |
| 22 |
| 20 | 18 | 16 |
| 15 | 13 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 25 |
| 8.2 | 25 | 24 |
| 23 | 21 | 19 |
| 17 | 15 | 23 |
| 8.6 | 23 |
| 23 |
| 21 | 19 | 17 |
| 15 | 13 |
| 22 | 31 |
| 8.7 | 19 | 17 |
| 15 | 13 | 10 |
| - | - | 30 |
| 9.3 | 18 |
| 16 |
| 14 | 12 | 9 |
| - | - |
1.24 | 19 | 29 |
| 8.5 | 24 | 22 |
| 19 | 17 | 15 |
| 13 | 10 | 27 |
| 9.1 | 23 |
| 21 |
| 18 | 16 | 14 |
| 12 | 10 |
17 | 27 |
| 8.3 | 26 | 26 |
| 24 | 21 | 19 |
| 17 | 15 | 24 |
| 8.7 | 24 |
| 24 |
| 22 | 20 | 18 |
| 15 | 13 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 25 |
| 8.2 | 25 | 25 |
| 24 | 22 | 20 |
| 18 | 15 | 24 |
| 8.7 | 24 |
| 23 |
| 23 | 20 | 18 |
| 16 | 14 |
| 22 | 32 |
| 8.8 | 21 | 19 |
| 16 | 13 | 11 |
| - | - | 31 |
| 9.4 | 20 |
| 18 |
| 15 | 13 | 10 |
| - | - |
1.42 | 19 | 30 |
| 8.6 | 26 | 23 |
| 21 | 18 | 16 |
| 13 | 10 | 28 |
| 9.2 | 25 |
| 23 |
| 20 | 17 | 15 |
| 12 | 10 |
17 | 27 |
| 8.3 | 27 | 27 |
| 25 | 23 | 20 |
| 18 | 15 | 25 |
| 8.8 | 25 |
| 25 |
| 24 | 21 | 19 |
| 16 | 14 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 26 |
| 8.3 | 26 | 26 |
| 26 | 24 | 21 |
| 18 | 16 | 24 |
| 8.8 | 24 |
| 24 |
| 24 | 22 | 19 |
| 17 | 14 |
| 22 | 33 |
| 8.8 | 23 | 20 |
| 17 | 14 | 11 |
| - | - | 31 |
| 9.4 | 22 |
| 19 |
| 16 | 13 | 10 |
| - | - |
1.59 | 19 | 30 |
| 8.6 | 28 | 25 |
| 22 | 19 | 16 |
| 13 | 10 | 28 |
| 9.2 | 27 |
| 24 |
| 21 | 18 | 15 |
| 12 | 9 |
17 | 28 |
| 8.4 | 28 | 28 |
| 27 | 24 | 21 |
| 18 | 15 | 25 |
| 8.9 | 25 |
| 25 |
| 25 | 22 | 19 |
| 16 | 13 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 27 |
| 8.3 | 27 | 27 |
| 27 | 24 | 21 |
| 18 | 15 | 25 |
| 8.9 | 25 |
| 25 |
| 25 | 22 | 19 |
| 16 | 13 |
| 22 | 34 |
| 8.9 | 24 | 21 |
| 18 | 14 | 11 |
| - | - | 32 |
| 9.5 | 23 |
| 20 |
| 17 | 13 | 10 |
| - | - |
1.77 | 19 | 31 |
| 8.7 | 29 | 26 |
| 23 | 20 | 16 |
| 13 | 10 | 29 |
| 9.3 | 29 |
| 25 |
| 22 | 19 | 15 |
| 12 | 9 |
17 | 28 |
| 8.4 | 28 | 28 |
| 28 | 25 | 21 |
| 18 | 15 | 26 |
| 8.9 | 26 |
| 26 |
| 26 | 23 | 19 |
| 16 | 13 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 27 |
| 8.4 | 27 | 27 |
| 27 | 24 | 21 |
| 17 | 14 | 25 |
| 8.9 | 25 |
| 25 |
| 25 | 22 | 19 |
| 15 | 12 |
|
|
|
| Temperature | of Air on Condenser Coil 41°C |
|
|
| Temperature of Air on Condenser Coil 46°C |
| ||||||||||||||||
| 22 | 27 |
| 9.8 | 16 | 14 |
| 12 | 10 | 8 |
| - | - | 25 |
| 10.4 | 15 |
| 13 |
| 11 | 9 | 8 |
| - | - |
1.06 | 19 | 24 |
| 9.5 | 20 | 18 |
| 16 | 14 | 12 |
| 10 | 8 | 21 |
| 10.0 | 19 |
| 17 |
| 15 | 13 | 11 |
| 9 | 7 |
17 | 21 |
| 9.1 | 21 | 21 |
| 19 | 17 | 15 |
| 13 | 11 | 19 |
| 9.7 | 19 |
| 19 |
| 17 | 15 | 14 |
| 12 | 10 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 21 |
| 9.1 | 21 | 21 |
| 19 | 17 | 15 |
| 13 | 11 | 19 |
| 9.7 | 19 |
| 19 |
| 17 | 15 | 13 |
| 11 | 10 |
| 22 | 28 |
| 9.9 | 18 | 15 |
| 13 | 11 | 9 |
| - | - | 25 |
| 10.5 | 17 |
| 15 |
| 12 | 10 | 8 |
| - | - |
1.24 | 19 | 25 |
| 9.6 | 22 | 20 |
| 17 | 15 | 13 |
| 11 | 8 | 22 |
| 10.1 | 21 |
| 19 |
| 16 | 14 | 12 |
| 10 | 7 |
17 | 22 |
| 9.3 | 22 | 22 |
| 20 | 18 | 16 |
| 14 | 12 | 20 |
| 9.8 | 20 |
| 20 |
| 19 | 17 | 14 |
| 12 | 10 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 22 |
| 9.3 | 22 | 22 |
| 21 | 18 | 16 |
| 14 | 12 | 20 |
| 9.8 | 20 |
| 20 |
| 19 | 16 | 14 |
| 12 | 10 |
| 22 | 28 |
| 10.0 | 19 | 17 |
| 14 | 12 | 9 |
| - | - | 26 |
| 10.6 | 19 |
| 16 |
| 13 | 11 | 8 |
| - | - |
1.42 | 19 | 25 |
| 9.7 | 24 | 21 |
| 19 | 16 | 14 |
| 11 | 9 | 23 |
| 10.2 | 23 |
| 20 |
| 18 | 15 | 13 |
| 10 | 7 |
17 | 23 |
| 9.4 | 23 | 23 |
| 22 | 20 | 17 |
| 14 | 12 | 21 |
| 9.9 | 21 |
| 21 |
| 21 | 18 | 15 |
| 13 | 10 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 22 |
| 9.4 | 22 | 22 |
| 22 | 20 | 17 |
| 15 | 12 | 20 |
| 9.9 | 20 |
| 20 |
| 20 | 18 | 15 |
| 12 | 10 |
| 22 | 29 |
| 10.1 | 21 | 18 |
| 15 | 12 | 9 |
| - | - | 27 |
| 10.7 | 20 |
| 17 |
| 14 | 11 | 8 |
| - | - |
1.59 | 19 | 26 |
| 9.8 | 25 | 23 |
| 20 | 17 | 14 |
| 11 | 8 | 23 |
| 10.3 | 23 |
| 22 |
| 19 | 16 | 13 |
| 10 | 7 |
17 | 23 |
| 9.4 | 23 | 23 |
| 23 | 20 | 17 |
| 14 | 11 | 21 |
| 10.0 | 21 |
| 21 |
| 21 | 18 | 15 |
| 12 | 9 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 23 |
| 9.4 | 23 | 23 |
| 23 | 20 | 17 |
| 14 | 11 | 21 |
| 10.0 | 21 |
| 21 |
| 21 | 18 | 15 |
| 12 | 9 |
| 22 | 29 |
| 10.1 | 22 | 19 |
| 16 | 13 | 9 |
| - | - | 27 |
| 10.8 | 21 |
| 18 |
| 15 | 12 | 8 |
| - | - |
1.77 | 19 | 26 |
| 9.8 | 26 | 24 |
| 21 | 18 | 14 |
| 11 | 8 | 24 |
| 10.4 | 24 |
| 23 |
| 20 | 16 | 13 |
| 10 | 7 |
17 | 24 |
| 9.5 | 24 | 24 |
| 24 | 20 | 17 |
| 14 | 11 | 21 |
| 10.1 | 21 |
| 21 |
| 21 | 18 | 15 |
| 12 | 8 | |
|
|
|
|
|
|
|
| |||||||||||||||||||
| 14 | 23 |
| 9.5 | 23 | 23 |
| 23 | 20 | 17 |
| 13 | 10 | 21 |
| 10.1 | 21 |
| 21 |
| 21 | 18 | 14 |
| 11 | 8 |
|
|
|
| Temperature | of Air on Condenser Coil 52°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| 22 | 23 |
| 11.0 | 14 | 12 |
| 11 | 9 | 7 |
| - | - | 1 These capacities are gross ratings. For net |
| |||||||||||
1.06 | 19 | 19 |
| 10.5 | 18 | 16 |
| 14 | 12 | 10 |
| 8 | 6 |
| ||||||||||||
|
|
|
|
| capacity, deduct air blower motor. Refer to the |
| ||||||||||||||||||||
17 | 17 |
| 10.2 | 17 | 17 |
| 16 | 14 | 12 |
| 10 | 8 |
|
|
| |||||||||||
|
|
|
|
|
|
| ||||||||||||||||||||
|
|
|
|
|
| appropriate Blower Performance Table for the |
| |||||||||||||||||||
| 14 | 17 |
| 10.2 | 17 | 17 |
| 15 | 13 | 12 |
| 10 | 8 |
|
|
| ||||||||||
| 22 | 23 |
| 11.1 | 16 | 14 |
| 12 | 9 | 7 |
| - | - |
|
| kW of the supply air blower motor. |
|
|
|
| ||||||
1.24 | 19 | 20 |
| 10.6 | 20 | 17 |
| 15 | 13 | 11 |
| 9 | 6 | 2 |
| These ratings include condenser fan motors |
| |||||||||
17 | 18 |
| 10.3 | 18 | 18 |
| 17 | 15 | 13 |
| 11 | 9 |
|
| and the compressor motors but not the supply |
| ||||||||||
|
|
|
|
|
|
| ||||||||||||||||||||
| 14 | 18 |
| 10.3 | 18 | 18 |
| 17 | 14 | 12 |
| 10 | 8 |
|
| air blower motor. |
|
|
|
|
|
|
|
| ||
| 22 | 24 |
| 11.2 | 18 | 15 |
| 13 | 10 | 7 |
| - | - |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
1.42 | 19 | 20 |
| 10.8 | 20 | 19 |
| 17 | 14 | 11 |
| 9 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
17 | 18 |
| 10.4 | 18 | 18 |
| 18 | 16 | 14 |
| 11 | 9 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| 14 | 18 |
| 10.5 | 18 | 18 |
| 18 | 16 | 13 |
| 10 | 8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 22 | 25 |
| 11.4 | 19 | 16 |
| 13 | 10 | 7 |
| - | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.59 | 19 | 21 |
| 10.9 | 21 | 20 |
| 18 | 15 | 12 |
| 9 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
17 | 19 |
| 10.5 | 19 | 19 |
| 19 | 16 | 13 |
| 10 | 7 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| 14 | 19 |
| 10.6 | 19 | 19 |
| 19 | 16 | 13 |
| 10 | 7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 22 | 25 |
| 11.5 | 21 | 17 |
| 14 | 11 | 8 |
| - | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.77 | 19 | 21 |
| 11.0 | 21 | 21 |
| 19 | 15 | 12 |
| 9 | 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
17 | 19 |
| 10.6 | 19 | 19 |
| 19 | 16 | 12 |
| 9 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| 14 | 19 |
| 10.7 | 19 | 19 |
| 19 | 16 | 12 |
| 9 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Unitary Products | 15 |