SECTION 4. TROUBLESHOOTING

Model OFG- 390

SECTION 4. TROUBLESHOOTING

4-1. TROUBLE SHOOTING GUIDE

 

 

 

Problem

 

Cause

 

Correction

 

Power switch on but fryer

Open circuit

Fryer plugged in

completely inoperative

 

 

• Check breaker or fuse at wall

 

 

 

 

 

Shortening not heating

Gas valve knob turned to the

Make sure gas control valve knob is

 

 

 

OFF position

 

turned to the ON position

 

 

Drain valve open

Close drain valve

 

 

• High temperature limit tripped

• Reset high temperature limit; see

 

 

 

 

 

Operating Controls Section

 

 

 

 

Foaming or boiling over

See Boil-Over chart on fryer

• Follow boil-over procedures from

 

 

 

and beginning of Operation

 

chart.

 

 

 

Section in this manual

 

 

 

 

 

 

 

Shortening not draining

Drain valve clogged

Push cleaning rod through open

 

 

 

 

 

drain valve.

 

 

 

 

 

Filter motor won’t run

Motor overheated

Reset motor; see Filter Motor Protector-

 

 

 

 

 

Manual Reset Section

 

 

 

 

 

Product Color Not

 

 

 

 

 

Correct:

 

 

• Check temperature setting in the Program

 

A. Too Dark

Temperature too high

 

 

 

 

 

Mode

 

 

• Breading to far in advance

• Bread product closer to frying period

 

 

 

 

 

 

B. Too Light

Temperature too low

• Check temperature setting in the Program

 

 

 

 

 

Mode

 

 

Fryer incorrect preheat

• Allow proper preheat time

 

 

Wrong product button pressed

Be sure to press the correct product to

 

 

 

 

 

be cooked

 

 

 

 

 

 

 

C. Product Greasy

Shortening old

Replace shortening

 

 

Temperature too low

• Check temperature setting in the Program

 

 

 

 

 

Mode

 

 

Frypot overloaded

Reduce cooking load

 

 

• Product not removed from frypot

• Remove product form frypot promptly

 

 

 

immediately after end of cycle

 

 

More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com,