Henny Penny OFG-390 Model OFG, gas fryers only, shortening level also referred to as fill lines

Models: OFG-390

1 51
Download 51 pages 48.88 Kb
Page 49
Image 49
shortening level (also referred to as fill lines)

 

Model OFG- 390

gas control valve

an automatic dual controller that controls gas to both pilot lights and gas

(gas fryers only)

pressure to burners on fryers; if either pilot light goes out, the controller shuts

 

off the gas to the other pilot light

gas valve knob

the knob that opens and closes the gas control valve

(gas fryers only)

 

gas pressure regulator

a device located on the gas control valve that regulates the gas

(gas fryers only)

pressure; the

pressure specifications are preset at the factory

heat indicator

the light that illuminates when the shortening is being heated; the light goes off

 

when the preset shortening temperature has been achieved

heating elements

the coils located inside the frypot on electric fryers that heat the shortening

high limit

a temperature control that opens and shuts off the heat to the frypot if it senses

 

shortening temperature in excess of 420°F (212°C)

ignition modules

two modules that send electrical energy to the spark igniters that ignite the pilot

 

lights on gas fryers

L-shaped brush

a brush included with the fryer that is used to clean around the burner tubes

 

and heating elements

landing table

another name for a dumping table (see dumping table)

level indicator lines

the lines marked on the interior real wall of the frypot that show the proper

 

shortening level (also referred to as fill lines)

lid assembly

an assembly comprised of lid, lid handle, and lid latch which raises and lowers

 

product into shortening on eight head fryers

lid handle

a handle that is attached to the lid and is used to lower the lid into contact with

 

the frypot; the handle is then pulled forward and pushed down to lock the lid in

 

place (see lid latch)

lid latch

a mechanical catch on the front of the fryer lid that engages a bracket located on

 

the front of the frypot; the latch holds the lid down

manual reset lever

resets high limit (OE-100 only)

manual shutoff valve

a valve located between the fryer and the wall that shuts off the flow of gas from

(gas fryers only)

the supply line; this is not the main shutoff valve for the store

melt cycle

a heat mode that cycles on and off to slowly melt the shortening when the

 

power switch is on and the shortening temperature is below a certain

 

temperature; the melt cycle prevents scorching of the shortening

pilot orifice

a controlled opening for the pilot light located on the burner assembly

(gas fryers only)

 

pilot light

a small flame that remains burning even when the fryer is not in use; the flame

(gas fryers only)

ignites the gas when the fryer is turned on

303

G-3

Page 49
Image 49
Henny Penny OFG-390 manual Model OFG, gas fryers only, shortening level also referred to as fill lines