2-9. ELECTRICAL

 

Model OFG- 390

2-9. ELECTRICAL

The gas fryer requires 120 volt, single phase 60 Hertz, 10

REQUIREMENTS

amp, 3 wire grounded (earthed) service, or 230 volt, single phase,

 

50 Hertz service. The 120 volt gas fryer is factory equipped with a

 

grounded (earthed) cord and plug for your protection against

 

shock, and should be plugged into a 3 prong grounded (earthed)

 

receptacle. Do not cut or remove grounding (earthing) prong. A

 

wiring diagram is located behind the right side panel, and can be

 

accessed by removing the side panel. The 230 volt plug must

 

conform to all local, state, and national codes.

To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded (earthed). Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No. 70-(the current edition). In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1, and/or local codes.

To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors. The main power switch on this appliance does not disconnect all line conductors.