3-15. PROGRAMMING

 

Model OFG- 390

3-15. PROGRAMMING

1. Press and hold the FUNCTION button for two seconds.

 

“REG PROGRAM” shows in the display, followed by

 

“CODE”.

2.Press the code 1,2,3, “SELECT PRODUCT” scrolls across the display.

If no buttons are pressed, within approximately 1 minute while in the Program Mode, the controls will revert back to the Cook Mode.

3.Press the appropriate product button, (1-0), to identify what product you want to program.

4.“INT1” and “TIME” flashes on the left side of the display. The right side will show the starting time of the Cook Cycle and can be changed by pressing the appropriate numbers. Ex: Press 1,0,0,0 and 10:00 flashes on the right side of the display, setting the start time at 10 minutes.

5.After the time is set, press and release the FUNCTION button and “INT1” and “TEMP” flashes on the left side of the display. The right side will show the starting temperature and can be changed by pressing the appropriate numbers. Ex: Press 2,5,0 and “250° F” will show on the right side of the display, setting the start temperature at 250° Fahrenheit.

6.After the temperature is set, press and release the FUNCTION button and “INT1”, “LOAD”, and “COMP.” flashes on the left side of the display. The factory preset load compensation value shows in the right side of the display.

7.After the load compensation, press and release the FUNC- TION button. “PROP” and “CONTROL” shows on the left side of the display and the factory preset proportional control temperature shows on the right side of the display.