| Model OFG- 390 |
| In the event of a control system failure, the digital display shows an | ||
|
| error message. These messages are coded: “E04”, “E05”, “E06”, | |
|
| “E32”, “E41” and “E71”. A constant tone is heard when an error | |
|
| code is displayed, and to silence this tone, press any of the product | |
|
| buttons. |
|
|
|
|
|
DISPLAY | CAUSE |
| PANEL BOARD CORRECTION |
|
|
| |
“E04” | Control board overheating | Turn switch to OFF position, then turn | |
|
|
| switch back to ON; if display still shows |
|
|
| “E04”, the board is getting too hot; check for |
|
|
| signs of overheating behind the control |
|
|
| panel; once panel cools down the controls |
|
|
| should return to normal; if “E04” persists, |
|
|
| have control panel replaced |
|
|
| |
“E05” | Shortening overheating | Turn switch to OFF position, then back to | |
|
|
| ON; if display shows “E05”, the heating |
|
|
| circuits and temperature probe should be |
|
|
| checked; once the unit cools down, the |
|
|
| controls should return to normal; if “E05” |
|
|
| persists, have control panel replaced |
|
|
| |
“E06” | Temperature probe failure | Turn switch to OFF position, then back to | |
|
|
| ON; if the display shows “E06”, the tempera- |
|
|
| ture probe should be checked; once the |
|
|
| probe is repaired, or replaced, the controls |
|
|
| should return to normal; if “E06” persists, |
|
|
| have control panel replaced |
|
|
|
|
“E41” | Programmingfailure |
| Turn switch to OFF position, then back to |
|
|
| ON; if display shows “E41”, the control |
|
|
| should be |
|
|
| Section) if the error code persists, have control |
|
|
| panel replaced |
“E71” |
|
| |
Pump motor relay failure or | Replace relay if contacts are stuck closed; | ||
| wiring problem |
| check wiring on POWER/PUMP switch, or at |
|
|
| wall receptacle; L1 and N may be reversed |
“E32, FAN FAIL |
|
| |
Air pressure switch open; clogged | Clean dilution box or replace blower if | ||
ERRORCHECK | dilution box or faulty blower; open | necessary; have drain switch checked; reset | |
BLOWER, CLEAN | drain switch; open high limit | high limit or have high limit checked | |
DILUTIONBOX, |
|
|
|
CALLHENNY |
|
|
|
PENNYSERVICE” |
|
|
|