4-2. ERROR CODES

 

 

 

Model OFG- 390

4-2. ERROR CODES

In the event of a control system failure, the digital display shows an

 

 

error message. These messages are coded: “E04”, “E05”, “E06”,

 

 

“E32”, “E41” and “E71”. A constant tone is heard when an error

 

 

code is displayed, and to silence this tone, press any of the product

 

 

buttons.

 

 

 

 

 

DISPLAY

CAUSE

 

PANEL BOARD CORRECTION

 

 

 

“E04”

Control board overheating

Turn switch to OFF position, then turn

 

 

 

switch back to ON; if display still shows

 

 

 

“E04”, the board is getting too hot; check for

 

 

 

signs of overheating behind the control

 

 

 

panel; once panel cools down the controls

 

 

 

should return to normal; if “E04” persists,

 

 

 

have control panel replaced

 

 

 

“E05”

Shortening overheating

Turn switch to OFF position, then back to

 

 

 

ON; if display shows “E05”, the heating

 

 

 

circuits and temperature probe should be

 

 

 

checked; once the unit cools down, the

 

 

 

controls should return to normal; if “E05”

 

 

 

persists, have control panel replaced

 

 

 

“E06”

Temperature probe failure

Turn switch to OFF position, then back to

 

 

 

ON; if the display shows “E06”, the tempera-

 

 

 

ture probe should be checked; once the

 

 

 

probe is repaired, or replaced, the controls

 

 

 

should return to normal; if “E06” persists,

 

 

 

have control panel replaced

 

 

 

 

“E41”

Programmingfailure

 

Turn switch to OFF position, then back to

 

 

 

ON; if display shows “E41”, the control

 

 

 

should be re-initialized (See Programming

 

 

 

Section) if the error code persists, have control

 

 

 

panel replaced

“E71”

 

 

Pump motor relay failure or

Replace relay if contacts are stuck closed;

 

wiring problem

 

check wiring on POWER/PUMP switch, or at

 

 

 

wall receptacle; L1 and N may be reversed

“E32, FAN FAIL

 

 

Air pressure switch open; clogged

Clean dilution box or replace blower if

ERRORCHECK

dilution box or faulty blower; open

necessary; have drain switch checked; reset

BLOWER, CLEAN

drain switch; open high limit

high limit or have high limit checked

DILUTIONBOX,

 

 

 

CALLHENNY

 

 

 

PENNYSERVICE”

 

 

 