Henny Penny OFG-390 manual Datos Tecnicos Para Products CE

Models: OFG-390

1 51
Download 51 pages 48.88 Kb
Page 5
Image 5
Datos Tecnicos Para Products CE

Model OFG- 390

 

Technical Data for CE Marked Products

Nominal Heat Input:

Natural (I2H) = 26,4 kW

(90,000 Btu/h)

(Net)

Natural (I2E) = 26,4 kW (90,000 Btu/h)

 

Natural (I2S) = 23,75 kW (81,000 Btu/h)

 

Liquid Propane (I3P) = 27,0 kW

(92,000 Btu/h)

Nominal Heat Input:

Natural (I2H) = 29,3 kW

(100,000 Btu/h)

(Gross)

Natural (I2E) = 29,3 kW (100,000 Btu/h)

 

Natural (I2S) = 26,4 kW (90,000 Btu/h)

 

Liquid Propane (I3P) = 29,3 kW

(100,000 Btu/h)

Supply Pressure:

Natural (I2H) = 20 mbar

 

 

 

Natural (I2E) = 20 mbar

 

 

 

Natural (I2S) = 25 mbar

 

 

 

Liquid Propane (I3P) = 37/50 mbar

 

Test Point Pressure:

Natural (I2H) = 8,7 mbar

 

 

 

Natural (I2E) = 8,7 mbar

 

 

 

Natural (I2S) = 8,7 mbar

 

 

 

Liquid Propane (I3P) = 25 mbar

 

Injector Size:

Natural (I2H) = 2,51 mm

 

 

 

Natural (I2E) = 2.51 mm

 

 

Natural (I2S) = 2.85 mm

Liquid Propane (I3P) = 1,04 mm

This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force and only used in a suitable ventilated location. Read the instructions fully before installing or using the appliance.

 

Datos Tecnicos Para Products CE

Consumo Calorico Nominal:

Gas Natural (I2H) = 26,4 kW

(90,000 Btu/h)

(Neto)

Gas Natural (I2E) = 26,4 kW (90,000 Btu/h)

 

Gas Natural (I2S) = 23,75 kW (81,000 Btu/h)

 

Propano Licuado (I3P) = 27,0 kW

(92,000 Btu/h)

Consumo Calorico Nominal:

Gas Natural (I2H) = 29,3 kW

(100,000 Btu/h)

(Bruto)

Gas Natural (I2E) = 29,3 kW (100,000 Btu/h)

 

Gas Natural (I2S) = 26,4 kW (90,000 Btu/h)

 

Propano Licuado (I3P) = 29,3 kW

(100,000 Btu/h)

Presion De Alimentacion:

Gas Natural (I2H) = 20 mbar

 

 

 

Gas Natural (I2E) = 20 mbar

 

 

 

Gas Natural (I2S) = 25 mbar

 

 

 

Propano Licuado (I3P) = 37/50 mbar

Presion En Ez Punto De Prueba:

Gas Natural (I2H) = 8,7 mbar

 

 

 

Gas Natural (I2E) = 8,7 mbar

 

 

 

Gas Natural (I2S) = 8,7 mbar

 

 

 

Propano Licuado (I3P) = 25 mbar

 

Diámetro Boquilla:

Gas Natural (I2H) = 2,51 mm

 

 

 

Gas Natural (I2E) = 2.51 mm

 

 

Gas Natural (I2S) = 2.85 mm

Propano Licuado (I3P) = 1,04 mm

Este equipo debe instalarse únicamente en un recinto adecuadameute ventilado y conforme a las indicaciones del fabricante y a las normas vigentes. Lea completamente las instrucciones antes de instalar o usar este equipo.

Page 5
Image 5
Henny Penny OFG-390 manual Datos Tecnicos Para Products CE