| Model OFG- 390 |
| |
(Continued) |
|
High Limit | This high temperature control senses the temperature of the short- |
| ening; if the temperature of the shortening exceeds 450°F |
| (230°C), this control will open and shut off the heat to the frypot; |
| when the temperature of the shortening drops to a safe operation |
| limit, the control must be manually reset by pressing the red reset |
| button, located under the control panel, in the front of the fryer |
Figure |
|
Ignition Modules | The two ignition modules send 24 volts to the gas control valve and |
| high voltage to the ignitors |
Spark Ignitors | When the pilots are being lit, the spark ignitors are electrically |
| energized and the tip of the ignitors spark to ignite the pilot lights |
Flame Sensors | Sense the pilot lights when the power switch is turned on; if the |
| pilots go out, or do not light, the flame sensors shutd the gas off, via |
| the modules |
Gas Control Valve | Adual controller, in which, one side of the valve controls the pilot |
| light and the other side controls the main burner |
Airflow Switch | Senses the flow of air coming from the blower; if the airflow is |
| reduced below a set amount, the switch cuts power to the gas |
| control valve, which shuts down the burners |
| To avoid property damage, do not tamper with or disas- |
| semble this component. It is set and sealed form the |
| factory and is not to be adjusted. |
Blower | Adds the proper amount of air into the burner tubes, so an efficient |
| combustion takes place, and also, pulls the flue gases out to the flue |
Air Valve | Pumps air into the shortening, periodically, to keep the shortening at |
| a uniform temperature; this only functions when the unit has been |
| sitting idle for a period of time and when heating up from a cold |
| start |
703 |