Model OFG- 390

3-1. OPERATING COMPONENTS

 

(Continued)

 

High Limit

This high temperature control senses the temperature of the short-

 

ening; if the temperature of the shortening exceeds 450°F

 

(230°C), this control will open and shut off the heat to the frypot;

 

when the temperature of the shortening drops to a safe operation

 

limit, the control must be manually reset by pressing the red reset

 

button, located under the control panel, in the front of the fryer

Figure 3-1

 

Ignition Modules

The two ignition modules send 24 volts to the gas control valve and

 

high voltage to the ignitors

Spark Ignitors

When the pilots are being lit, the spark ignitors are electrically

 

energized and the tip of the ignitors spark to ignite the pilot lights

Flame Sensors

Sense the pilot lights when the power switch is turned on; if the

 

pilots go out, or do not light, the flame sensors shutd the gas off, via

 

the modules

Gas Control Valve

Adual controller, in which, one side of the valve controls the pilot

 

light and the other side controls the main burner

Airflow Switch

Senses the flow of air coming from the blower; if the airflow is

 

reduced below a set amount, the switch cuts power to the gas

 

control valve, which shuts down the burners

 

To avoid property damage, do not tamper with or disas-

 

semble this component. It is set and sealed form the

 

factory and is not to be adjusted.

Blower

Adds the proper amount of air into the burner tubes, so an efficient

 

combustion takes place, and also, pulls the flue gases out to the flue

Air Valve

Pumps air into the shortening, periodically, to keep the shortening at

 

a uniform temperature; this only functions when the unit has been

 

sitting idle for a period of time and when heating up from a cold

 

start

3-2