4-2. ERROR CODES (Continued)

 

 

 

Model OFG- 390

4-2. ERROR CODES (Continued)

CE Only - Along with the error codes from page 4-2, CE

 

 

 

 

units have the following self-diagnostic error codes:

 

 

 

 

DISPLAY

CAUSE

 

PANEL BOARD CORRECTION

“E10”

Highlimit

 

Reset the high limit by manually pushing up on the red reset

 

 

 

button; if the high limit does not reset, the high limit must be

 

 

 

replaced

 

 

 

 

“E15”

Drain switch

 

Close the drain, using the drain valve handle; if display still

 

 

 

shows “E-15”, have the drain microswitch checked

 

 

 

 

“E-20A”

Air pressure

 

Press the timer button to try the ignition process again,

 

switch failure

 

and if “E-20A” persists, call Henny Penny’s Service

 

(stuck closed)

 

Department

 

 

 

 

“E-20 B”

Draft fan or

 

Press the timer button to try the ignition process again,

 

air pressure

 

and if “E-20 B” persists, call Henny Penny’s Service

 

switch failure

 

Department

 

(stuck open)

 

 

 

 

 

 

“E-20 C”

Left gas module

 

Press the timer button to try the ignition process again, and if

 

failure

 

“E-20 C” persists, call Henny Penny’s Service Department

 

 

 

 

“E20 D”

Rightmodule

 

Press the timer button to try the ignition process again, and if

 

failure

 

“E-20 D”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 E”

Both modules

 

Press the timer button to try the ignition process again, and if

 

failure

 

“E-20 E”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 F”

Left module

 

Press the timer button to try the ignition process again, and if

 

no flame sense

 

“E-20 F”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 G”

Rightmodule

 

Press the timer button to try the ignition process again, and if

 

no flame sense

 

“E-20 G”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 H”

Both modules

 

Press the timer button to try the ignition process again, and if

 

no flame sense

 

“E-20 H”, persists, call Henny Penny’s Service Department

 

 

 

 