Model OFG- 390
2-7. GAS LEAK TEST
Prior to turning the gas supply on, be sure the gas valve knob on the gas control valve is in the OFF position. The word “OFF” is at the bottom of the knob when the valve is closed.
Upon initial installation and after moving the unit, the pipings and fittings should be checked for gas leaks.Asimple checking method is to turn on the gas and brush all connections with a soap solution. If bubbles and occur, it indicates escaping gas. In this event, the piping connection must be redone.
| To avoid fire or explosion, never use a lighted match |
| or open flame to test for gas leaks. Ignited gas could |
| result in severe personal injury and/or property |
| damage. |
| The gas pressure regulator on the gas control valve is |
REGULATOR SETTING | factory set as follows: |
| Natural: 3.5 inches water column (.87 kPa) |
| Propane: 10.0 inches water column (2.49 kPa) |
| The gas pressure regulator has been set by Henny Penny and |
| is not to be adjusted by the user. |
MAKE SURE GAS PRESSURE IS SET COR-
RECTLY. FAILURE TO DO SO CAN RESULT IN
SHORTENINGOVERFLOWINGTHE FRYPOT,
WHICH COULD CAUSE SERIOUS BURNS,
PERSONAL INJURY, FIRE AND/OR PROPERTY
DAMAGE.
703 |