Model OFG- 390
|
|
(Continued) | Tech I/O Mode |
| 1. Press and hold the FUNCTION button for two seconds until |
| “REG PROGRAM” shows in the display. As soon as |
| “REG PROGRAM” shows in the display, press and release |
| the FUNCTION button 4 times until “TECH |
| the display. |
| 2. When “CODE” shows in the display, press |
| for CE units). “HEAT’, and “PUMP” shows alternately in the |
| display. Also, the LEDs over 1 and 3 flashes alternately. |
| 3. To test the heat circuit, press and hold the 1 button. |
| 4. To test the pump system, press and hold the 3 button. |
| To test the heat output on CE units, the blower and modules |
| must first be turned on . |
| Appliance Test |
| Press and hold the FUNCTION button for two seconds until |
| “REG PROGRAM” shows in the display. As soon as |
| “REG PROGRAM” shows in the display, press and release |
| the FUNCTION button 5 times until “APPL TEST” shows |
| in the display. |
| With the power switch on, the display will show “CURR=”, |
| along with the time it took the unit to heat from 250º to |
| 300º F (121ºto 149º C) . This is normally recorded from the |
| initial heat up in the morning. |