Henny Penny OFG-390 manual Special Program, Heat Control, MODE Continued

Models: OFG-390

1 51
Download 51 pages 48.88 Kb
Page 43
Image 43
3-16. SPECIAL PROGRAM

 

 

Model OFG- 390

3-16. SPECIAL PROGRAM

 

Heat Control

MODE (Continued)

1.

Press and hold the FUNCTION button for two seconds until

 

 

“REG PROGRAM” shows in the display. As soon as

 

 

“REG PROGRAM” shows in the display, press and release

 

 

the FUNCTION button 6 times until “HEAT CNTRL” shows

 

 

in the display.

 

2. When “CODE” shows in the display, press 1-2-3-4.

 

 

“MELT”, “EXIT”, and “TEMP” flashes in the display, along

 

 

with the shortening temperature at which the unit will exit the

 

 

melt cycle. This should be set at 180º F (82º C), and should

 

 

not be changed until the factory is consulted.

 

3. Press and release the FUNCTION button and ”MELT”,

 

 

“CYCLE”, and “100s” shows alternately in the display, along

 

 

with the period (pulse) length of 4000. This should not be

 

 

changed until the factory is consulted.

 

4.

Press and release the FUNCTION button twice and

 

 

“MELT”, “ON-”, “TIME”, and “100s”, shows alternately in

 

 

the display, along with the length of time the heat is on. This

 

 

should be set at 1700, and should not be changed until the

 

 

factory is consulted.

5. Press and release the FUNCTION button three times and “COOL”, “SET-”, and “POINT” shows alternately in the display, along with the temperature at which the control exits the melt cycle. This is set at 250º F (121º C), and should not be changed until the factory is consulted.

6. Press and release the FUNCTION button four times and “AUTO”, and “IDLE” shows alternately in the display, along with “OFF”. This should not be changed until the factory is consulted.

7. Press and release the FUNCITON button five times and “AUTO”, “IDLE”, and “MMSS” shows alternately in the display, along with “0:00”. This should not be changed until the factory is consulted.

8. The last 3 functions in the Heat Control Mode are used by the factory only, and should not be changed.

703

3-21

Page 43
Image 43
Henny Penny OFG-390 manual Special Program, Heat Control, MODE Continued