FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before run- ning heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Set switch in the OFF position.

16

www.desatech.com

116412-01B

Image 16
Contents Models VFRMV18NB, VFRMV18PB VFRMV24NB and VFRMV24PB Ansi Z21.11.2b-2004 Ansi Z21.60-2003Table of Contents Safety Information Safety Information Optional Remote Control Accessories Product FeaturesProduct Identification Local CodesAir For Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow For Appliance LocationVentilation AIR AIR for Combustion VentilationVentilation Air From Inside Building Installation Ventilation Air From OutdoorsCheck GAS Type Installation and Clearances for vent-free operationCeiling Safe Installation Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Remote Control Accessory bracketInstalling Heater Assembly Masonry Manufactured FireplaceFireplaceConnecting to GAS Supply Installation Items NeededPressure Testing Gas Supply Propane/LP From Checking GAS ConnectionsPiping System Test Pressures In Excess Of 1/2 Psig KPa Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Heater For Your Safety Read Before LightingLighting Instructions Operating Heater To Turn OFF GAS To AppliancePropane/LPNatural Shutting Off HeaterManual Lighting Procedure Optional Hand-HeldRemote Operation On/Off Series Model HRC100Safety Features Auto Shutoff FeatureKey Pad Lock Feature Inspecting BurnersBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder Pilot Air Inlet Hole Cleaning Maintenance Wiring DiagramTechnical Service Propane/LPTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Maintenance,Operation Processes and logs curing Hours of operation Gas leak. See warning Checking Gas ConnectionsSpecifications Replacement PartsService Hints AccessoriesAccessories Illustrated Parts Breakdown Models VFRMV18NB, VFRMV18PB, VFRMV24NB Shown and VFRMV24PBParts List 116412-01B 116412-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VFRMV18PB, VFRMV18NB, VFRMV24NB, VFRMV24PB specifications

The Desa VFRMV series is a sophisticated line of heating solutions known for its efficiency and modern design. The models in this series include the VFRMV24NB, VFRMV24PB, VFRMV18NB, and VFRMV18PB, each sharing a commitment to provide superior comfort and versatility in various living spaces.

One of the most notable features of the VFRMV series is its advanced heating technology. These units are equipped with a powerful burner system designed to maximize heat output while minimizing energy consumption. This makes the units not only environmentally friendly but also cost-effective, as users can enjoy warm indoor spaces without incurring high energy bills. The gas burners achieve a high thermal efficiency, ensuring that a significant amount of heat is delivered into the room promptly.

The VFRMV series is designed with customer convenience in mind. The models feature easy-to-read digital displays that allow users to adjust temperatures and settings effortlessly. These displays are intuitive, providing feedback on heating levels, operational status, and timer functions, enhancing the user experience. Furthermore, the inclusion of a remote control option allows homeowners to manage the heating from the comfort of their sitting area.

In terms of safety, the VFRMV series implements several key features. Each unit is equipped with an oxygen depletion sensor and a safety shut-off system. This ensures that the unit operates safely within its designated space, automatically shutting down if carbon monoxide levels rise or oxygen levels drop beyond safe limits. This commitment to safety provides peace of mind for households, making it a suitable choice for a wide range of environments.

Aesthetically, the VFRMV24NB and VFRMV24PB models feature a sleek design, with the "NB" models showcasing a bold black finish, while the "PB" variants offer a more classic propane-blue coloration. The smaller VFRMV18 series similarly combines elegance with functionality, ensuring that they can seamlessly blend into any home décor.

In summary, the Desa VFRMV24NB, VFRMV24PB, VFRMV18NB, and VFRMV18PB models exemplify modern heating solutions. With their advanced burner technology, user-friendly features, stringent safety measures, and stylish designs, they cater to contemporary requirements for effective indoor heating. Whether for residential or commercial use, the VFRMV series promises reliability and comfort all year round.